Product catalog summary
Overview: The Model 7810 with Respiration is Ivy Biomedical’s advanced cardiac trigger monitor, offering gating outputs for ECG R-wave peaks and user-selectable points in the respiratory cycle. This enhances scan quality by allowing technicians to remove blurry image slices caused by chest movement and can reduce radiation exposure by avoiding unnecessary scans.
Intuitive Operation: The device features an AUTO lead select function to optimize ECG signal quality, ensuring reliable cardiac triggers. It also measures skin-to-electrode impedance for scan reliability and is available with an optional integrated strip chart recorder.
Integrated Design: The Model 7810 includes a touchscreen interface displaying two waveforms: a Trigger ECG vector and either a second ECG vector or a respiration waveform. Adjustable heart rate alarm limits provide audible and visual alerts for violations.
Respiratory Acquisition: Utilizes a pneumatic technique with a foam-filled pillow to detect chest expansion during respiration, providing a respiratory waveform for analysis.
Accessories: Includes various lead wires, patient cables, ECG electrodes, recorder paper, and a respiration pillow with associated components.
ECG Viewer Software: Comes with a USB drive containing software for detailed ECG waveform analysis.
Technical Specifications: Features include a TFT color touchscreen, various ECG lead options, and a range of respiratory performance metrics. The device supports a wide range of environmental conditions and has specific power requirements.
Regulatory Compliance: The Model 7810 meets several international standards, including AAMI, UL, CSA, and IEC specifications.
Contact Information: Ivy Biomedical Systems, Inc., Branford, Connecticut, USA. Website: www.ivybiomedical.com
See more

Catalog excerpts

7810-1

Synchronization Redefined NOT RELEASED BY THE FDA FOR MARKETING WITHIN THE UNITED STATES Cardiac/Respiration Trigger Monitor The Model 7810 with Respiration is Ivy Biomedical’s fifth generation of cardiac trigger monitors providing gating outputs for both ECG R-wave peaks and for user selectable points in the respiratory cycle. Respiratory gating produces better quality scans by enabling technicians to pinpoint and remove blurry image slices which were obtained during periods of chest movement. Respiration gating can be used by some scanners to prospectively avoid scanning to reduce total radiation exposure. Intuitive Operation Acquiring a trigger ECG can often be challenging task, and selecting the right ECG vector can be problematic. The Model 7810 includes an AUTO lead select feature (Trigger lead only). When se- lected, this feature will determine which lead (I, II or III) provides for the best signal amplitude-to-noise ratio of the ECG signal and thus a more reliable cardiac trigger. The Model 7810 also has special hardware and software that measures skin to electrode impedance, ensuring a reliable scan. The Model 7810 is available with or without an integrated strip chart recorder. Integrated Design The hardware design incorporates a simple, easy to use touchscreen interface displaying two waveforms; the top waveform is dedicated as the Trigger ECG vector and can be selected from Leads I, II III or Auto Lead Select. The bottom waveform can be either a Second ECG vector (Leads I, II, or III) or a Respiration waveform. If required, High and Low heart rate alarm limits can be adjusted to bracket the patient’s heart rate so that a violation of these limits produces an audible and visual indication of the alarm. Respiratory Acquisition The 7810 utilizes a pneumatic technique which responds to the expansion of the chest during respiration. A foam filled pillow is attached to the patient with a elasticized strap, and the air pressure changes as the chest moves and compresses the pillow. UNITED STATES FEDERAL LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN. ©2012 Ivy Biomedical Systems Inc. All Rights Reserved. P/N: 3290-01-16 Rev. 04

 Open the catalog to page 1
7810-2

Accessories Standard 2842-00-10 Respiration Pillow Strap 3031-00-10 Respiration Pillow Hose 590035 Recorder Paper (10 Rolls)

 Open the catalog to page 2
7810-3

World-Class Cardiac Triggering Respiratory Cycle Side Input Connector Panel A color Trigger mark clearly indicates the timing of each synch pulse with respect to the ECG, providing a visual reference for timing and synchronization. The ECG Menu shown above provides technicians with options and preferences for optimal cardiac gating. Trigger marks indicate the peaks of the inspiration and expiration respiration waveform. The Respiration waveform is displayed in yellow, and red during trigger time. Synchronized trigger output starts at the peak of the inspiration waveform and can be delayed up...

 Open the catalog to page 3
7810-4

Technical Specifications Lead Selection Trigger Lead Second Lead Patient Cable 4 Lead cable with 6 PIN AAMI standard con- nector, isolated from ground related circuits by Frequency Response Electrode Impedance Measurement Recommended Electrode Tall T Wave Rejection T waves < 1.2 * R-wave Pacer Pulse Rejection Writing Method Direct Thermal Active Matrix TFT Color Touch Screen refer to Operator Manual Respiratory Performance Digitization Rate: Waveform transmission Rate: Digitization Resolution: Baseline restoration: Respiratory Patient Connection Pneumatic connection: Colder Products Hose to pillow...