Synchronization Redefined Cardiac Trigger Monitor The Model 7600 is Ivy Biomedical’s fifth generation cardiac trigger monitor with the intended use primarily on patients in applications requiring precision ECG Rwave synchronization. Incorporating a simple, easy-to-use touchscreen interface, the 7600 displays two simultaneous ECG vectors, along with the patient’s heart rate. Intuitive Operation Acquiring an ECG trigger can often be a challenging task, and selecting the right ECG vector can be problematic. The 7600’s AUTO lead select feature (Trigger lead only) will determine which lead (I, II or III) provides for the best amplitude-to-noise ratio of the ECG signal and, thus, a more reliable cardiac trigger. Patient Monitoring When required, high and low heart rate alarm limits can be adjusted to bracket a patient’s heart rate, so that a violation of these limits produces an audible and visual indication of the alarm. Imaging Applications The 7600 Monitor provides world-class cardiac triggering for use in synchronized applications, such as Nuclear Imaging. Precision Engineering A color Trigger mark clearly indicates the timing of each synch pulse with respect to the ECG, providing a visual reference for timing and synchronization. Improved Communications The Model 7600 has an electrically isolated RS-232 connector that provides twoway direct communications between the monitor and the external console for the transfer of ECG data. The Model 7600 is available with or without an integrated strip chart recorder. UNITED STATES FEDERAL LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN. ©2015 Ivy Biomedical Systems Inc. All Rights Reserved. P/N: 3284-00-16 Rev. 07 EN November 16, 2015 Trigger Mark
Open the catalog to page 1
Accessories AHA-Compatible 590035 Recorder Paper (10 Rolls)
Open the catalog to page 2
World-Class Cardiac Triggering Integrated Chart Recorder Optional recorder prints ECG strips on demand for manual review. Touch Screen Operation Quickly adjust alarm limits, or make adjustments on the fly using the on-screen menus and buttons. Mounting Solutions Ivy Biomedical has a custom-designed, light-duty roll stand that enhances the maneuverability of the 7600. Please contact us for more information, or for custom requirements. 590441 Roll stand (shown)* *Requires 3302-00-15 Roll stand Mounting Kit
Open the catalog to page 3
Technical Specifications Trigger Lead I, II, III, and AUTO Patient Cable 4 Lead cable with 6 PIN AAMI standard connector, isolated from ground related circuits Frequency Response Electrode Impedance Measurement Recommended Electrode 10% Chloride sponge type (590436) Tall T Wave Rejection T waves < 1.2 * R-wave Pacer Pulse Rejection Writing Method Direct Thermal Synchronized Output (Trigger)* Output Trigger Delay < 2 ms R to R Trigger Accuracy ±75 us typical Pulse Width Options 1, 50, 100 or 150ms Pulse Amplitude Options * Test input signal at ECG leads Conditions: Vi sine wave, 60ms width,...
Open the catalog to page 4All Ivy Biomedical Systems Inc catalogs and technical brochures
-
7810
4 Pages
-
PAM-200
2 Pages
-
Model 7800
4 Pages
-
Model 6000
2 Pages