Product Overview: The Melissa 12 overlay mattress is designed to provide pressure relief and is placed on top of another foam mattress. It helps prevent pressure ulcers up to Category 2 and is made of high-quality, highly elastic cold foam with a density of 50kg/m3. The mattress height is 6cm.
Hygiene Covers: RX hygiene covers are available to protect the mattress. They are waterproof, breathable, and made from bi-elastic polyurethane fabric. Two variants are available: RXH-5 with handles and RXH-5 Resår with handles and elasticated fastening. Covers have a protective flap over the zips for hygiene.
Testing and Standards: The mattress has been tested for pressure management by Swerea IVF. It meets fire safety standards SS 8760001, EN 597-1, and 2. Pressure measurement is conducted using impression bodies as per Swedish standard SS 8760013.
Specifications: Standard sizes range from 200/205 x 80/85/90/100/105/120 x 6cm. The mattress supports user weights up to 150kg and weighs approximately 4kg. It is fully recyclable as combustible waste.
Warranty and Labelling: The mattress core has a 2-year warranty, and the hygiene cover has a 3-year warranty against manufacturing defects. Labels include the date of manufacture, EAN, care instructions, and compliance standards.
Pressure Measurement Results: For the Melissa 12 overlay mattress, pressure results are 34 mm Hg for a large impression body at 300 N, 52 mm Hg at 600 N, and 60 mm Hg for a small impression body at 40 N.
See more

Catalog excerpts

MELISSA 12 overlay mattress-1

The Melissa 12 overlay is a pressure-relieving mattress which is placed on top of another foam mattress. It can aid the prevention of pressure ulcers up to and including Category 2. The mattress has a height of 6cm and is made of high-quality, highly elastic cold foam (50kg/m3), providing both comfort and pressure relief at the same time. CHOOSE A HYGIENE COVER FOR YOUR MATTRESS Our RX hygiene covers are waterproof and prevent urine, blood etc. from penetrating through to the mattress core. The hygiene covers are breathable and made of a rustle-free, bi-elastic polyurethane fabric. There is a stitched zip on 3 sides to facilitate removal for washing. The RX covers are available in two variants: • RXH-5 – with handles. • RXH-5 Resår – with handles and elasticated fastening. For hygiene reasons, the zips on all covers have a protective flap. 6cm highly elastic cold foam 50kg/m Always make a risk assessment when using elastic in the case of young children. Product Specifications FIRE SAFETY STANDARDS: The mattresses are tested and approved according to SS 8760001, EN 597-1 and 2. STANDARD SIZES: (LxWxH) 200/205 x 80/85/90/100/105/120 x 6 cm. For other sizes please contact Järven Health Care. WARRANTIES: Mattress core: 2 years for manufacturing defects. Hygiene cover: 3 years for manufacturing defects. PRESSURE ULCER CATEGORY: 1-2. RECYCLING: The mattress and cover are completely energy-recoverable and can be sorted as combustible waste. No disassembly is necessary. USER WEIGHT: Up to 150kg. MATTRESS WEIGHT: Approximately 4kg depending on the mattress size. MATERIAL: 6cm highly elastic cold foam 50 kg/m3. LABELLING: Date of manufacture, EAN, care instructions, compliant standards and placement in bed. The Melissa 12 overlay mattress has undergone pressure management testing at the independent testing institute Swerea IVF. This provides an objective assessment of the pressure relief properties of the mattress. In the case of overlay mattresses, the result is affected by the base mattress used underneath. See below for the results. Mattress Melissa 12 overlay mattress Large impression body 300 N Large impression body 600 N PRESSURE MEASUREMENT FACTS To avoid individual influences from different people, Swerea IVF has developed impression bodies, which simulate the shape of selected parts of the human body. Giving these impression bodies a load that is representative of an average human body, different mattresses and beds can be evaluated objectively using pressure mats. The measurement method is described in the Swedish standard SS 8760013. Small impression body 40 N Classification of pressure results for mattresses in new condition (mm Hg). Load Large impression body 300 N Large impression body 600 N Small impression body 40 N MELISSA is Järven Health Care’s range of pressure relieving standard mattresses with hygiene covers. Read the user guide before using the product. Bromsvägen 3 | SE-891 60 Örnsköldsvik | SWEDEN Telephone: +46 660-22 28 50 | Fax: +46 660-824 10 www.jarven.se | [email protected] Melissa 12 overlay mattress, rev. 19.09.00

 Open the catalog to page 1

All Järven catalogs and technical brochures

  1. Air0

    2  Pages

  2. MELISSA FLEX

    1  Page

  3. MELISSA 12

    1  Page

  4. OPTICELL 4 NX

    2  Pages

  5. OPTICELL 4 NX

    2  Pages

  6. OptiCell 2 NX

    2  Pages

  7. OptiCell 3 NX

    2  Pages

  8. Rescue Sheet

    1  Page

  9. CPR board

    1  Page

  10. Zussa Pillow

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.