1. Catalogs
  2. Järven
  3. MELISSA FLEX

MELISSA FLEX

MELISSA FLEX

Product catalog summary
Product Overview: The MELISSA FLEX is a two-layer pressure-relieving mattress designed to prevent pressure ulcers up to Category 2. It features a 14cm height with a 6cm viscoelastic memory foam upper layer and an 8cm highly elastic cold foam lower layer, both with a volume weight of 50kg/m3.
Hygiene Covers: The RX series hygiene covers are waterproof, breathable, and made of bi-elastic polyurethane fabric. They come in three variants: RX-5 (standard), RXH-5 (with handles), and RXI-5 (with handles and evacuation function). All covers have a protective flap over the zips.
Specifications: Standard sizes range from 200 x 80 to 200 x 120 cm. The mattress supports user weights up to 150kg and weighs approximately 12kg. It meets fire safety standards SS 8760001, EN 597-1, and 2. The mattress core has a 3-year warranty against fatigue, and the hygiene cover has a 3-year warranty for manufacturing defects.
Recycling and Labelling: The mattress and cover are fully energy-recoverable and can be disposed of as combustible waste. Labels include the date of manufacture, EAN, care instructions, and compliant standards.
Pressure Measurement: Testing by Swerea IF using impression bodies simulates human body pressure. Results for the Melissa Flex mattress are 31 mm Hg for a large impression body at 300 N, 51 mm Hg at 600 N, and 62 mm Hg for a small impression body at 40 N.
See more

Catalog excerpts

MELISSA FLEX-1

MELISSA FLEX is a two-layer pressure-relieving mattress with a height of 14 cm. It can aid the prevention of pressure ulcers up to and including Category 2. The mattress is composed of two foam core layers that are placed inside a removable hygiene cover. The upper layer has a height of 6cm and is made of viscoelastic memory foam that has pressure relieving properties. The lower layer has a height of 8cm and is made of highly elastic cold foam that prevents the patient "bottoming out”. The volume weight of each foam is 50kg/m3. CHOOSE A HYGIENE COVER FOR YOUR MATTRESS THE RX SERIES Our RX hygiene covers are waterproof and prevent urine, blood etc. from penetrating through to the mattress core. The hygiene covers are breathable and made of a rustle-free, bi-elastic polyurethane fabric. There is a stitched zip on 3 sides (4 sides on the RXI-5) to facilitate removal for washing. The RX covers are available in three variants: • RX-5 - standard cover. • RXH-5 - with handles. • RXI-5 - with handles and built-in evacuation function. For hygiene reasons, the zips on all covers have a protective flap. Product Specifications STANDARD SIZES: (LxWxH) 200 x 80/85/90/105/120 x 14cm. For other sizes please contact Jarven Health Care. PRESSURE ULCER CATEGORY: 1-2. USER WEIGHT: Up to 150kg. MATTRESS WEIGHT: Approximately 12 kg depending on the mattress size. MATERIALS: 6cm viscoelastic memory foam 50kg/m3. 8cm highly elastic cold foam 50kg/m3. FIRE SAFETY STANDARDS: The mattresses are tested and approved according to SS 8760001, EN 597-1 and 2. WARRANTIES: Mattress core: 3 years on fatigue of mattress core (B-rating according to SS 8760011). Hygiene cover: 3 years for manufacturing defects. RECYCLING: The mattress and cover are completely energy-recoverable and can be sorted as combustible waste. No disassembly is necessary. LABELLING: Date of manufacture, EAN, care instructions, compliant standards and placement in bed. The Melissa Flex mattress has undergone pressure management testing at the independent testing institute Swerea IF. This provides an objective assessment of the pressure relief properties of the mattress. See below for the results. To avoid individual influences from different people, Swerea IVF has developed impression bodies, which simulate the shape of selected parts of the human body. Giving these impression bodies a load that is representative of an average human body, different mattresses and beds can be evaluated objectively using pressure mats. The measurement method is described in the Swedish standard SS 8760013. MELISSA is Jarven Health Care's range of pressure relieving standard mattresses with hygiene covers. J : Read the user guide before using the product. jarven diecittn Cate Bromsvagen 3 | SE-891 60 Ornskoldsvik | SWEDEN Telephone: +46 660-22 28 50 | Fax: +46 660-824 10 www.jarven.se | [email protected]

 Open the catalog to page 1

All Järven catalogs and technical brochures

  1. Air0

    2  Pages

  2. MELISSA 12

    1  Page

  3. OPTICELL 4 NX

    2  Pages

  4. OPTICELL 4 NX

    2  Pages

  5. OptiCell 2 NX

    2  Pages

  6. OptiCell 3 NX

    2  Pages

  7. Rescue Sheet

    1  Page

  8. CPR board

    1  Page

  9. Zussa Pillow

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.