1. Catalogs
  2. Jeil Medical Corporation
  3. ARIX System Product Catalog
video corpo

ARIX System Product Catalog

ARIX System Product Catalog
1 / 62 PagesView full catalog

ARIX System Product Catalog

Product catalog summary
Overview: The JEILMEDICAL Corporation product catalogue provides comprehensive details on the ARIX systems, which are designed for various orthopedic applications. These systems include hand, wrist, humerus, clavicle, elbow, foot, ankle, diaphysis, and cannulated screw systems, offering a range of plates and screws tailored to specific anatomical needs.
ARIX Hand System: This system features hand plates with screw sizes ranging from 1.5 mm to 2.3 mm and plate thicknesses from 0.6 mm to 1.3 mm. Made from biocompatible titanium, the plates incorporate a new locking mechanism with variable angle technology, anatomically pre-contoured designs, and low-profile screw heads for enhanced stability and reduced operating room time.
ARIX Wrist System: The wrist system includes volar distal radius plates with poly-axial locking mechanisms and rounded edges to minimize soft tissue irritation. It offers locking and non-locking screws in various diameters and lengths, with plates designed for optimal fitting and minimal tendon interference.
ARIX Humerus and Clavicle Systems: These systems provide proximal humerus and clavicle plates designed to support bone healing and stability, accommodating different anatomical structures and fracture types.
ARIX Elbow, Foot, and Ankle Systems: These systems include plates for elbow, fore/midfoot, calcaneal, and fibula applications, designed to provide stability and support for various fracture types and anatomical locations.
ARIX Diaphysis and Cannulated Screw Systems: The diaphysis system offers plates for long bone fractures, while the cannulated screw system provides screws in multiple sizes for versatile orthopedic applications.
Key Features: The catalogue highlights the use of biocompatible materials, color-coded implants for easy identification, and advanced locking mechanisms to enhance surgical outcomes. The systems are designed to reduce surgical time and improve patient recovery through precise anatomical fitting and stability.
Radiocarpal Joint Construction: Features direct vision construction with restoration of length and axes, fixed angle plates eliminating the need for cancellous bone grafting, and early functional rehabilitation due to reduced plate thickness.
Plate and Screw Specifications: Locking screws are available in diameters from Ø 2.0 mm to Ø 3.5 mm, self-tapping, and made from titanium alloy. Non-locking screws are similarly available, with color coding for easy identification. Plates are available in various configurations, including clavicle, olecranon, distal humerus, and proximal radius plates, all made from pure titanium.
Instruments: The catalogue lists necessary instruments such as drill bits, screwdrivers, and depth gauges, each specified for compatibility with different screw and plate sizes.
Set Configuration Suggestions: Recommendations are provided for assembling sets of plates and screws for specific surgical needs, ensuring compatibility and efficiency in surgical procedures.
Conclusion: The catalogue serves as a comprehensive guide for selecting and configuring orthopedic surgical components, with detailed specifications and configurations to support various surgical applications.
See more

Catalog excerpts

ARIX System Product Catalog-1

PRODUCT CATALOGUE JEILMEDICAL CORPORATION .Af^X SYSTEM I MEDICAL

 Open the catalog to page 1
ARIX System Product Catalog-2

PRODUCT CATALOGUE JEILMEDICAL CORPORATION .Af^X SYSTEMJEILMEDICAL

 Open the catalog to page 2
ARIX System Product Catalog-3

PRODUCT CATALOGUE JEILMEDICAL CORPORATION ARIX Hand System 5 1.5 / 1.8 / 2.0 / 2.3 Hand Plate ARIX Wrist System 9 1.5 / 2.0 / 2.5 Volar Distal Radius Plate ARIX Wrist System 13 2.5 Dorsal Distal Radius Plate ARIX Wrist System 15 2.5 Carpal Fusion Plate ARIX Wrist System 17 2.8 Ulna Osteotomy Plate ARIX Wrist System 19 2.0 Distal Ulna Plate ARIX Humerus System 21 3.5 / 4.0 Proximal Humerus Plate ARIX Clavicle System 23

 Open the catalog to page 3
ARIX System Product Catalog-4

PRODUCT CATALOGUE JEILMEDICAL CORPORATION ARIX Elbow System 27 ARIX Foot System 33 2.3 / 2.8 Fore / Midfoot Plate ARIX Foot System 37 ARIX Ankle System 39 3.5 Anterolateral Distal Fibula Plate ARIX Ankle System 41 2.8 / 3.5 Lateral Distal Fibula Plate ARIX Ankle System 43 3.5 Fibula Hook Plate ARIX Diaphysis System 45 ARIX Cannulated Screw System 47

 Open the catalog to page 4
ARIX System Product Catalog-5

PRODUCT CATALOGUE JEILMEDICAL CORPORATION ARIX Hand System General features H1 plate with thickness 0.6 mm (green) • Comprehensive plates and screws to treat full range of hand fractures • Biocompatible titanium materials • Color coded implants and instruments for quick identification Offers better locking condition Offers variable angle locking technology Anatomically pre-contoured plate design Less bending/OR time Low profile screw head H2 plate with thickness 1.0 mm (blue) H2 plate with thickness 1.3 mm (silver) Offset plate holes Improved rotational stability through offset hole align

 Open the catalog to page 5
ARIX System Product Catalog-6

JEILMEDICAL CORPORATION Variable angle locking technology • H1 Sytem: holes allow 15° off-axis screw angulation in all directions • H2 Sytem: holes allow 10° off-axis screw angulation in all directions Locking and non-loking screw options Holes accepts both of locking and non-locking screws Non-locking screws Locking screw Self-retaining screwdriver shaft No necessity of holding sleeve Screwdriver Length Emergency to Screw Color Material 1.8 non-locking ~ 20 mm screw length Cross Head Silver O 6, 10 mm 2.3 non-locking ~ 20 mm screw length Hexa Head 6, 10 mm Titanium Alloy

 Open the catalog to page 6
ARIX System Product Catalog-7

PRODUCT CATALOGUE JEILMEDICAL CORPORATION H1 System Set Configuration Suggestions 01.5 mm Locking Screws H1L-ST-006 Straight Length 26 mm, 6 Holes, Green 3 H1L-ST-016 Straight Length 71 mm, 6 Holes, Green 3 H1L-ST-104 Straight Length 18.5 mm, 4 Holes, Green 3 H1L-QD-112 Matrix Length 33.5 mm, 12 Holes, Green 3 H1L-TP-007 T Length 27 mm, 7 Holes, Green 3 H1L-YP-006 Y Length 22.5 mm, 6 Holes, Green 3 H1L-LL-005 L Left, Length 18.3 mm, 5 Holes, Green 3 H1L-LR-005 L Right, Length 18.3 mm, 5 Holes, Green 3 1 112-104-3 ARIX Hand H1 System Tray 1 4 113-NF-101 Cruciform Screwdriver Shaft 2 7 111-124...

 Open the catalog to page 7
ARIX System Product Catalog-8

PRODUCT CATALOGUE JEILMEDICAL CORPORATION H2 System Set Configuration Suggestions 02.0 mm LockingSere ws 1 H2L-ST-004 Straight Length 26.2 mm, 4 Holes, Blue 3 2 H2L-ST-006 Straight Length 35.2 mm, 6 Holes, Blue 3 3 H2L-ST-016 Straight Length 90.2 mm, 16 Holes, Blue 3 4 H2L-QD-006 Matrix Length 21.3 mm, 12 Holes, Blue 3 5 H2L-TP-007 T Length 31.0 mm, 7 Holes, Blue 3 6 H2L-YP-006 Y Length 31.0 mm, 6 Holes, Blue 3 7 H2L-YP-007 Y Length 36.4 mm, 7 Holes, Blue 3 8 H2L-LL-006 L Left, Length 31.5 mm, 6 Holes, Blue 3 9 H2L-LR-006 L Right, Length 31.5 mm, 6 Holes, Blue 3 4 113-HF-103 Hexagonal Screwdriver...

 Open the catalog to page 8
ARIX System Product Catalog-9

PRODUCT CATALOGUE Rounded plate edges to minimize soft tissue irritation JEILMEDICAL CORPORATION Minimal screw head prominence rounded screw head Screw Types OuterDiameter Insertion Types Screw Head Recess Cross Head Titanium Alloy

 Open the catalog to page 9
ARIX System Product Catalog-10

PRODUCT CATALOGUE JEILMEDICAL CORPORATION Standard • Anatomically designed for maximum support of lunate facet and stable fixation of radial styloid process • Window for fracture line position • Drill guide block for accurate drilling angle Juxta-Articular Type • Pre-defined screw angle for radial styloid process fixation • No screw penetration through articular surface • Minimized interference with FPL tendon Volar Rim Type • Bendable lugs for fixation of volar rim fracture (1.5 mm locking screw) • Pre-defined screw angle for radial styloid process fixation • Minimized interference with FPL...

 Open the catalog to page 10
ARIX System Product Catalog-11

PRODUCT CATALOGUE JEILMEDICAL CORPORATION Set Configuration Suggestions 01.5 mm Locking Screws 02.5 mm L ocking Sere ws Description 0 2.5 mm Non-Locking screws Description 0 20 mm Smooth Peg Screws (optional) Code Description 1 25-DVRA-109-R Standard Medium, 9 Holes, Right, Light Blue 3 2 25-DVRA-109-L Standard Medium, 9 Holes, Left, Light Green 3 3 25-DVRA-110-R Standard Medium, 10 Holes, Right, Light Blue 2 4 25-DVRA-110-L Standard Medium, 10 Holes, Left, Light Green 2 5 25-DVRA-111-R Standard Medium, 11 Holes, Right, Light Blue 1 6 25-DVRA-111-L Standard Medium, 11 Holes, Left, Light Green...

 Open the catalog to page 11
ARIX System Product Catalog-12

PRODUCT CATALOGUE JEILMEDICAL CORPORATION 1 111-226 Drill Sleeve for 0 1.5 mm Screws, Fixed Angle 1 2 111-101 Drill Sleeve for 0 2.5 mm Screws, Fixed Angle 1 3 111-103 Drill Sleeve, Variable Angle 1 4 111-157 Drill Sleeve Handle, Variable Angle 1 7 113-NF-101 Screwdriver Shaft for 0 1.5 mm Screws 2 8 113-HF-613 Screwdriver Shaft for 0 2.5 mm Screws 2 9 111-080 Drill Guide, Variable Angle 1 10 111-075 Depth Gauge for 0 2.5 mm Screws 1 16 111-082-R Drill Guide Block, Standard, Medium, Right 1 17 111-082-L Drill Guide Block, Standard, Medium, Left 1 18 111-083-R Drill Guide Block, Standard, Large,...

 Open the catalog to page 12
ARIX System Product Catalog-13

PRODUCT CATALOGUE ARIX Wrist System 2.5 Dorsal Distal Radius Plate JEILMEDICAL CORPORATION General Features • Anatomic reconstruction of the radiocarpal joint under direct vision. • Restoration of length and axes. • No need for cancellous bone grafting if fixed angle plates are used. • Early functional rehabilitation of the wrist. • The plates are not prominent due to their reduced thickness. Screw Specifications Screw Types Outer Diameter Length Insertion Types Screw Head Recess Color Material Locking Non-Locking Blue 0 2.5 mm 8 ~ 26 mm Self-Tapping STARIX Titanium Alloy Plate Types Thickness...

 Open the catalog to page 13

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.