Catalog excerpts
JEIL MEDICAL Mid Face / Orthognathic / Mandible Trauma / Mandible Recon.
Open the catalog to page 1Indication Overview Features and Benefits Ordering Information_Screws - 1.3 Micro Screw - 1.6 Mid Screw - 2.0 Mini Screw - 2.0 Mini Locking Screw - 2.4 Maxi Screw - 2.4 Maxi Locking Screw - Auto Screw - IMF Screw Ordering Information_Plates - Mid Face Plate (Micro) - Mid Face Plate (Mid) - Orthognathic Plate (Mini) - Mandible Trauma Plate (Mini) - Mandible Recon. Plate (Maxi) - Mesh Ordering Information_Instruments - Instrument - Mandible Reduction Dual Forceps - Angled Driver - Tray & Container
Open the catalog to page 2This device is intended for use in selective trauma of the mid-face; reconstruction procedures; and selective orthognathic surgery of the maxilla and chin.
Open the catalog to page 3Overview Leforte System II has Four tray for Midface, Mandible Trauma, Orthognathic and Mandible Recon. They are made of aluminum material providing durability and stability. Leforte System II is intended for use in Orthognathic Surgery, Mid Face Fractures, Mandible Fractures, Mandible Subcondyler Fractures, and Mandible Reconstruction. LeForte 1, 2, and 3 fractures Orthognathic surgery of midface and mandible Selected orthonathic procedures Oral and maxillofacial trauma and osteotomy Nasal, orbital, and zygoma region Trauma and osteotomy of mandible Reconstruction of mandible Materials of...
Open the catalog to page 4Features & Benefits Features and Benefits Locking plates have same outer size with normal mini plates Usually plate outline tends to be bigger in case of locking mechanism. All mini locking plates in LeForte System have same outline size with conventional mini plates. Mini Plate, Locking Uniform Hole Distance for 100% Compatibility with 3 Prong Bender L, Y, Z shaped mini plates have uniform hole distances. 3 Prong Bender works with L, Y, Z shaped mini plates in 100% compatibility. Locking and Cortical Screws can be used in a same plate hole Mini and Maxi locking plates accept both of...
Open the catalog to page 5Features & Benefits Features and Benefits Strength Reinforced Micro and Mid screws in LeForte System have increased strength in screw head and threads than conventional screws. Uniform and Optimal Screw Retention All screws in LeForte System are designed to have optimal screw to blade retention uniformly. Screw Thread design improvement for better bone grasp All screws in LeForte System have the modified geometrical threads design to enhance pull-out strength and bone grasp in final tightening of screw in bone. Screw Tip design improvement for less soft tissue irritation All screws in...
Open the catalog to page 61.3 Micro Screw Material: Titanium-6Aluminum-4Vanadium ELI Alloy Self-tapping Screws require drilling pilot hole prior to inserting screws into bone. Pilot hole diameter: 1.0 mm Corresponding instrumentation J-latch drill bits for 1.0mm diameter pilot hole: 112-MC-302, 112-MC-STOP, 122-MC-301 Dental latch drill bits for 1.0mm diameter pilot hole: 112-MC-201, 112-MC-202 Manual screwdriver shafts: 113-NF-101 Micro Cortical Screws Head Diameter Outer Diameter Core Diameter Micro Emergency Screws Head Diameter Outer Diameter Core Diameter LeForte System
Open the catalog to page 71.6 Mid Screw Material: Titanium-6Aluminum-4Vanadium ELI Alloy Self-tapping Screws require drilling pilot hole prior to inserting screws into bone. Pilot hole diameter: 1.3mm Corresponding instrumentation J-latch drill bits for 1.3mm diameter pilot hole: 112-MD-301, 112-MD-STOP, 112-MD-302 Dental latch drill bits for 1.3mm diameter pilot hole: 112-MD-201 Manual screwdriver shafts: 113-NF-101 Head Diameter Outer Diameter Core Diameter [Unit : mm] Silver Silver Silver Silver Silver Silver Silver Mid Emergency Screws Code Head Diameter Outer Diameter Core Diameter [Unit : mm] Purple Purple...
Open the catalog to page 82.0 Mini Screw Material: Titanium-6Aluminum-4Vanadium ELI Alloy Self-tapping Screws require drilling pilot hole prior to inserting screws into bone. Pilot hole diameter: 1.6mm Corresponding instrumentation J-latch drill bits for 1.6mm diameter pilot hole: 112-MN-STOP, 112-MN-306,112-MN-301,112-MN-302, 112-MN-303 Dental latch drill bits for 1.6mm diameter pilot hole: 112-MN-201, 112-MN-202 Straight drill bits for 1.6mm diameter pilot hole: 112-MU-301, 112-MU-302 Manual screwdriver shafts: 113-MX-101 Head Diameter Outer Diameter Core Diameter [Unit : mm] Blue Blue Blue Blue Blue Blue Blue...
Open the catalog to page 92.0 Mini Locking Screw Material: Titanium-6Aluminum-4Vanadium ELI Alloy Self-tapping Screws require drilling pilot hole prior to inserting screws into bone. Pilot hole diameter: 1.6mm Corresponding instrumentation J-latch drill bits for 1.6mm diameter pilot hole: 112-MN-STOP, 112-MN-306,112-MN-301,112-MN-302, 112-MN-303 Dental latch drill bits for 1.6mm diameter pilot hole: 112-MN-201, 112-MN-202 Straight drill bits for 1.6mm diameter pilot hole: 112-MU-301, 112-MU-302 Manual screwdriver shafts: 113-MX-101 Mini Locking Screws 10 Head Diameter Outer Diameter Core Diameter Gold Gold Gold Gold...
Open the catalog to page 102.4 Maxi Screw Material: Titanium-6Aluminum-4Vanadium ELI Alloy Self-tapping Screws require drilling pilot hole prior to inserting screws into bone. Pilot hole diameter: 2.0mm Corresponding instrumentation J-latch drill bits for 2.0mm diameter pilot hole: 112-MX-301, 112-MX-302 Dental latch drill bits for 2.0mm diameter pilot hole: 112-MX-201, 112-MX-202 Manual screwdriver shafts: 113-MX-101 Head Diameter Outer Diameter Core Diameter Silver Silver Silver Silver Silver Silver Silver Silver Silver Silver Maxi Emergency Screws Code Head Diameter Outer Diameter Core Diameter [Unit : mm] Purple...
Open the catalog to page 112.4 Maxi Locking Screw Material: Titanium-6Aluminum-4Vanadium ELI Alloy Self-tapping Screws require drilling pilot hole prior to inserting screws into bone. Pilot hole diameter: 2.0mm Corresponding instrumentation J-latch drill bits for 2.0mm diameter pilot hole: 112-MX-301, 112-MX-302 Dental latch drill bits for 2.0mm diameter pilot hole: 112-MX-201, 112-MX-202 Manual screwdriver shafts: 113-MX-101 Head Diameter Outer Diameter Core Diameter
Open the catalog to page 12Auto Screw Auto Screw Material: Titanium-6Aluminum-4Vanadium ELI Alloy Auto screws(Self-drilling) do not require drilling pilot hole to insert screws into bone. Corresponding instrumentation Micro - Manual screwdriver shafts: 113-NF-101 Mid - Manual screwdriver shaft: 113-NF-101 Mini - Manual screwdriver shafts: 113-MX-101 Head Diameter Outer Diameter Core Diameter [Unit : mm] Silver Silver Silver Silver Silver Silver Silver Mid Auto Screws [Unit : mm] Head Diameter Outer Diameter Core Diameter Mini Auto Screws [Unit : mm] Head Diameter Outer Diameter Core Diameter Silver Silver Silver...
Open the catalog to page 13All Jeil Medical Corporation catalogs and technical brochures
-
ARIX WRIST SYSTEM
36 Pages
-
Orthopedic - Arix Hand System
20 Pages
-
ARIX Ulna Osteotomy System
16 Pages
-
Cranial - Sterile NS System
16 Pages
-
Jeil Customized Implant
12 Pages
-
ARIX System Product Catalog
62 Pages
-
Cranial - Speedy Flap System
4 Pages
-
Orthopedic - ARIX Elbow
44 Pages
-
Orthopedic - ARIX Humerus System
20 Pages
-
Cranial - LeForte Neuro System
16 Pages
-
Cranial - Sterile NS Kit
2 Pages
-
OMF - Facial Bandage
2 Pages