Catalog excerpts

HUMERUS SYSTEM 3.5 / 4.0 Proximal Humerus Plate
Open the catalog to page 1
Indication Overview Surgical Technique Ordering Information_Plates Ordering Information_Screws - 0 3.5 mm Cortical Locking Screws - 0 3.5 mm Cortical Non-Locking Screws - 0 4.0 mm Cancellous Locking Screw Ordering Informationjnstmments Set Configuration Suggestions
Open the catalog to page 2
ARIX Humerus System is indicated for fractures, fracture dislocations, osteotomies, and nonunions of the proximal humerus, particularly in osteopenic bone.
Open the catalog to page 3
ARIX Humerus Plate The ARIX Humerus System is indicated for fractures, fracture dislocations, osteotomies and nonunions of the proximal humerus. Locking hole with pre-defined screw insertion angle Calcar screws can be inserted in user preferred angle Oblong hole for plate position adjustment Screw direction perpendicular to plate surface Commercially Pure Titanium, ASTM F-67 Ti-6Al-4V, ASTM F-136 ARIX Humerus System
Open the catalog to page 4
ARIX Humerus Screw Ø 3.5 mm Cortical Locking Screw Ø 4.0 mm Cancellous Locking Screw Ø 3.5 mm Cortical Non-Locking Screw Ø 3.5 mm Cortical Locking Screw 3.5 / 4.0 Proximal Humerus Plat
Open the catalog to page 5
Features - continued Special designed grooves enable suturing after the complete screw insertion Calcar screws can inserted in user preferred angle General Features • Anatomically Pre-contoured • Variable Locking up to ±15° • Left & Right Plate Variation for anatomical fitting • Suture Holes & Grooves for Additional Suturing • Plate Thickness 3.0 mm & 4.0 mm • Ø 3.5 mm Cortical Locking Screw, Ø 3.5 mm Cortical Non-Locking Screw, Ø 4.0 mm Cancellous Locking Screw Special Feature for Long Type Plates (Optional, thickness: 4 mm) • Limited Contact Design for Better Blood Supply • Extra Long...
Open the catalog to page 6
Variable Locking Interface with Locking Screw • Poly-axial Screw Insertion • Angle range: ±15° • Plate-Screw Locking Interface Variable Angle Locking 15° STARIX Screw with T10 • Prevent Cam-out • Allow Higher Torque Application • Self-Retaining function • Locking & Non-Locking Variations available Drill Guide Block for Optimal Screw Insertion Drill guide block ensures optimal screw insertion angles
Open the catalog to page 7
Surgical Technique The deltopectoral approach can be used for almost any proximal humeral fracture. 2. Fracture Reduction and Preliminary fixation Fractures in proximal humerus represent various fracture types. Reduction can be performed by suturing or pure traction depending on the type of fracture. After fracture reduction, hold the reduction manually or with a pointed reduction forceps. Temporarily secure it with 2 K-wires. Note: Ensure that K-wires do not interfere with correct plate placement Required Set ARIX Humerus System 112-122 ARIX Humerus System
Open the catalog to page 8
Surgical Technique 3. Plate positioning and initial fixation Place the plate in correct placement. 1. Align properly along the axis of the humeral shaft 2. More slightly posterior to the bicipital groove (2 ~ 4 mm) Place the drill guide(111-212) on the oblong hole in plate shaft for drilling. Using a Ø 2.7 mm drill bit(112-35-704), drill a hole with bi-cortical. Attach the plate to the humeral shaft with a 3.5 mm cortical screw in the oblong hole. Note : If necessary, assemble the drill sleeve handle(111-157) with a variable drill sleeve(111-172) for better visibility during operation....
Open the catalog to page 9
4. Fixation Attach the plate to the proximal humerus head & shaft with plate locking holes. Several types of screw can be used in plate locking holes. - 0 3.5 mm Cortical Locking Screw (35L-SO-LXX-TA) - 0 3.5 mm Cortical Non-Locking Screw (35-SO-LXX-T) - 0 4.0 mm Cancellous Locking Screw (40L-SA-XXX-TA) The procedures can be used in the following methods. Choose an appropriate drill sleeve between unidirectional sleeve(111-173) and variable angle sleeve(111-172) to drill holes. Do not drill through the subchondral bone and into the shoulder joint. Measure hole depth and choose an...
Open the catalog to page 10
Surgical Technique 5. Suturing and Final check Sutures placed through the insertions of each rotator cuff tendon increase stability. Pass the sutures through the corresponding holes in the plate and tie them together. Using image intensification, check carefully for correct reduction and fixation at various arm positions. Ensure that screw tips are not intraarticular. 6. Closure and Implant Removal Close Incision Use the appropriate method for surgical closure of the incision Implant Removal To remove locking screws, first unlock all screws from the plate; then remove the screws completely...
Open the catalog to page 11
Ordering Information - Plates 12 ARIX Humerus System
Open the catalog to page 12
Right Plates Code 13 3.5 / 4.0 Proximal Humerus Plate
Open the catalog to page 13
Ordering Information - Screws ARIX Humerus System Screws 0 3.5 mm Cortical Locking Screws(STARIX) Code Length Color Set Quantity 0 3.5 mm Cortical Non-Locking Screws(STARIX) Code Length Color Set Quantity ARIX Humerus System
Open the catalog to page 14
0 4.0 mm Cancellous Lockin (STARIX) Ordering Information - Screws Code Length Color Set Quantity 3.5 / 4.0 Proximal Humerus Plate
Open the catalog to page 15
Ordering Information - Instruments ARIX Hurmerus System Instruments Drill Bits Drill Bits for Ø 3.5 mm, Ø 4.0 mm Screws, AO Type Drill Sleeve & Drill Sleeve Handle Drill Sleeve for Ø 3.5 mm, Ø 4.0 mm Screws, Fixed Angle Drill Sleeve for Ø 3.5 mm, Ø 4.0 mm Screws, Variable Angle Drill Sleeve Handle Drill Guide Block ARIX Humerus System Drill Guide Block, Left Drill Guide Block, Right
Open the catalog to page 16
Code Description Set Quantity Code Description Set Quantity 111-212 Drill Guide for 0 3.5 mm, 0 4.0 mm Screws, Fixed Angle 1 Screwdriver Handle Code Description Set Quantity 111-181 Depth Gauge for 0 3.5 mm, 0 4.0 mm Screws 1 3.5 / 4.0 Proximal Humerus Plate
Open the catalog to page 17
Ordering Information - Instruments Code Description Set Quantity 112-122 ARIX Humerus System Tray 1 ARIX Humerus System
Open the catalog to page 18
ARIX Hurmerus Set Configuration 0 4.0 mm Cancellous Locking Screws Code Description 0 3.5 mm Cortica l Locking Screws No. Code Description 1 35L-SO-L20-TA 0 3.5 mm Cortical Locking Screw, Length 20 mm 5 2 35L-SO-L22-TA 0 3.5 mm Cortical Locking Screw, Length 22 mm 5 3 35L-SO-L24-TA 0 3.5 mm Cortical Locking Screw, Length 24 mm 5 4 35L-SO-L26-TA 0 3.5 mm Cortical Locking Screw, Length 26 mm 5 5 35L-SO-L28-TA 0 3.5 mm Cortical Locking Screw, Length 28 mm 5 6 35L-SO-L30-TA 0 3.5 mm Cortical Locking Screw, Length 30 mm 10 7 35L-SO-L32-TA 0 3.5 mm Cortical Locking Screw, Length 32 mm 10 8...
Open the catalog to page 19All Jeil Medical Corporation catalogs and technical brochures
-
ARIX WRIST SYSTEM
36 Pages
-
Orthopedic - Arix Hand System
20 Pages
-
ARIX Ulna Osteotomy System
16 Pages
-
Cranial - Sterile NS System
16 Pages
-
Jeil Customized Implant
12 Pages
-
ARIX System Product Catalog
62 Pages
-
Cranial - Speedy Flap System
4 Pages
-
Orthopedic - ARIX Elbow
44 Pages
-
Cranial - LeForte Neuro System
16 Pages
-
Cranial - Sterile NS Kit
2 Pages
-
OMF - Facial Bandage
2 Pages