62 Series Fluorimeters
8Pages

{{requestButtons}}

Catalog excerpts

62 Series Fluorimeters - 2

Intelligent... Three versatile models Wide ranging applications Easy intuitive operation Low maintenance Compatible with DataWay PC software .fluorimetry Jenway 62 Series Fluorimeters are designed to suit a wide range of budgets and applications. All three models offer intuitive operation with a user interface based on logical menus that can be navigated from a simple keypad. With press-to-read operation and Total Energy Transfer (TET) technology the output of the high-energy xenon lamp has an extended life expectancy and should never need replacing in normal use. High quality optics are...

Open the catalog to page 2
62 Series Fluorimeters - 3

• High sensitivity photomultiplier detector • Wavelength range 190 - 650nm • Raw fluorescence and concentration display • Kinetic (timed readings) function HOME RHODAMINE UT EXCITATION NM 546 UNITS ppb CALIBRATION SETUP Calibration Curve Method Setup Rhodamine WT The high sensitivity of fluorimetric measurement techniques enables trace levels to be determined in a broad range of samples. Selectivity is also enhanced enabling interference free analysis of even the most complex sample matrix. All models in the 62 Series enable simple raw fluorescence measurements to be made without...

Open the catalog to page 3
62 Series Fluorimeters - 4

• Red-enhanced photomultiplier detector • Wavelength range 190 - 850nm • Calibration with up to 6 standards • Method lock with password access Locked Setup Measuring Chlorophyll a Increasing levels of algae Where applications generate an Emission wavelength between 650 and 850nm, and the high sensitivity of a photomultiplier is still required, the model 6285 will fit the bill. The measurement of Chlorophyll a, Algal Pigments and Rhodamine B are just three examples of where this enhanced wavelength range will be required, while all the general applications can still be carried out. Like all...

Open the catalog to page 4
62 Series Fluorimeters - 5

• Rugged photodiode detector • Wavelength range 190 - 1100nm • Time and date stamped results • High quality, low cost measurement system Filter Status Method Setup Histamine Measuring Histamine The model 6270 is ideal for applications where higher levels of fluorescence are encountered as well as for experiments investigating the principles of fluorimetry and similar projects in education and training. For field analysis the 62 Series fluorimeters can be powered from a 12V dc supply and can be transported in the optional carry case for improved comfort and protection. Up to 100 results can...

Open the catalog to page 5
62 Series Fluorimeters - 6

Software DataWay gives you unlimited storage of results and graphs in files on your PC - by far the best and most secure way to store your personal data when working on a multi-user instrument. Because DataWay is so easy to use you won't hesitate to choose it for even the simplest tasks. Just press the Print key on the instrument or click the 'Take reading' button to transfer your data to the PC. Work with your data off-line with instant access to your nominated DataWay files through a single click on the Load icon. If you want your data in an Excel™ spreadsheet click the copy option and...

Open the catalog to page 6
62 Series Fluorimeters - 7

The programmable peristaltic sipper pump can be adjusted by the operator to inject a repeatable volume of sample/standard into the chamber of a flow-through cuvette. An air gap to separate samples may be selected as well as a wash cycle and the option to pump through the cuvette to waste or return the sample to its original container after measurement. The programme can also be overridden to pump sample continuously through the cuvette for monitoring a bulk or flowing sample over a period of time. Fluorescence intensity is inversely proportional to temperature so care must be taken...

Open the catalog to page 7
62 Series Fluorimeters - 8

Model Light Source Expected Lifetime Sensitivity (Quinine Sulphate) Dynamic Range Detector Wavelength Range Wavelength Selection Raw Fluorescence Concentration Calibration Kinetics (Timed Readings) Time Limits Methods Stored Results Stored GLP Outputs PC Software Sample Handling Heated Sample Holder (Option) Sipper Pump (Option) Power Supply Size Weight 6270_ Pulsed xenon lamp with press-to-read operation No replacement required in normal operation 1pg/ml 4 5.2 x 10 Photodiode 190 to 1100nm Intelligent Filter Modules (IFM) Yes Yes Blank + up to 6 standards In both above modes 1 reading...

Open the catalog to page 8

All Jenway catalogs and technical brochures

  1. Masterflex®

    2 Pages

  2. pH Buffers

    1 Pages

  3. 3520

    1 Pages

  4. 3510

    1 Pages

  5. Genova Plus

    4 Pages

  6. Genova Nano

    4 Pages

  7. PFP7

    1 Pages

  8. PFP7/C

    1 Pages

  9. 7305

    1 Pages

  10. 6305

    1 Pages

  11. 9500

    1 Pages

  12. 3505

    1 Pages

  13. 4520

    1 Pages

  14. 4510

    1 Pages

Archived catalogs

  1. 970

    1 Pages

  2. 6051

    2 Pages