Spectrophotometer Model Genova Bio L Spec ife Scien trop hoto ce mete r
Open the catalog to page 1Safety Please read this information carefully prior to installing or using this equipment. 1. The unit described in this manual is designed to be operated only by trained personnel. Any adjustments, maintenance and repair must be carried out as defined in this manual, by a person qualified to be aware of the hazards involved. 2. It is essential that both operating and service personnel employ a safe system of work, in addition to the detailed instructions specified in this manual. 3. Other than for those items defined in the maintenance procedures herein there are no user serviceable items...
Open the catalog to page 35. Si l’utilisateur suspecte qu’un problème quelconque puisse mettre en cause la sécurité, l’appareil doit être rendu inopérant en empêchant son utilisation. Communiquer la défaillance constatée au service de maintenance compétent. 6. Le symbole d’alerte signale à l’utilisateur les informations importantes concernant l’utilisation de l’appareil. Lire et suivre les instructions fournies avec la plus grande attention. 7. Cet appareil utilise une source lumineuse UV. Ne pas regarder directement vers la source. 8. ATTENTION. Si l’appareil n’est pas utilisé de manière adéquate, la protection de...
Open the catalog to page 48. ACHTUNG: Wenn das Gerät nicht in der vorgegebenen Weise eingesetzt wird, können die Schutzfunktionen des Gerätes beeinträchtigt werden. 9. Abnehmbares Anschlusskabel nicht durch unangemessen bewertete Kabel austauschen. Leggere attentamente queste istruzioni prima di installare o utilizzare il dispositivo. 1. L’unità descritta nel presente manuale è stata realizzata per essere utilizzata solo da personale che ha ricevuto l’apposita formazione. Qualsiasi operazione di regolazione, manutenzione e riparazione deve essere effettuata sulla base di quanto indicato nel presente manuale da...
Open the catalog to page 5Cualquier elemento que no se encuentre entre los definidos en los procedimientos de mantenimiento aquí descritos no podrá utilizarse en este instrumento. La extracción de las tapas y los intentos de ajuste o reparación por parte de personal no cualificado invalidarán la garantía y pueden incurrir en cargos adicionales por reparación. Siempre deberían consultarse los datos sobre Salud y Seguridad que se suministran con cualquier producto químico que se utilice. Es necesario llevar a cabo los procedimientos de laboratorio de aceptación generalizada para la manipulación segura de productos...
Open the catalog to page 6Contents Page Safety SECTION 1 - Introduction Front access panel 14 Lamp access panel 15 SECTION 3 - Theory and Practice of Spectroscopy Measurements 16 3.1 Theory of spectroscopy measurement 16 Nucleic acid determination Good practice guidelines 17 SECTION 4 - Instrument Setup 19 4.1 Navigating and screen setup 19 Instrument settings screen 19 Heated cell accessory control 21 SECTION 5 - Nucleic Acids 25 5.1 Method setup Measurement name Entering concentration units Selecting wavelength correction Entering a dilution factor Blank calibration and sample measurement 29
Open the catalog to page 7Selecting a protein assay Method setup Measurement name Entering concentration units Selecting the number of standards and replicates Selecting wavelength correction Measuring standards Load a standard curve Blank calibration and sample measurement Direct UV measurement mode Method setup Measurement name Entering concentration units Selecting wavelength correction Entering a dilution factor Blank calibration and sample measurement Warburg-Christian measurement mode Method setup Measurement name Entering concentration units Selecting wavelength correction Entering a dilution factor Blank...
Open the catalog to page 8Use a factor measurement mode Method setup Measurement name Blank calibration and sample measurement Use standard(s) measurement mode Method setup Measurement name Entering concentration units Selecting the number of standards and replicates Measuring standards Load standard curve Blank calibration and sample measurement Method setup Measurement name Selecting measurement mode Setting start and end wavelengths Blank calibration and sample measurement Data analysis Spectrum zoom Spectral points analysis Method setup 10.1.2 Selecting number of wavelengths 10.1.3 Selecting measurement mode...
Open the catalog to page 9SECTION 12 - Accessories and spare parts Optional accessories SECTION 13 - Maintenance and service 81 13.1 Routine maintenance and cleaning 81 Firmware update procedure 81 Power up calibration failure Error codes Troubleshooting guide Technical support SECTION 15 - Declaration of Conformity 87
Open the catalog to page 10INSTRUMENT DESCRIPTION The Genova Bio is a UV/visible spectrophotometer dedicated to life science analysis. This spectrophotometer allows the measurement of DNA concentrations and purity ratios using wavelengths recorded at 260, 280 and 230nm, with an optional correction at 320nm. The results displayed will include the concentration and purity ratios. At the touch of a button the results will switch the display to show the purity scan for that sample. The Genova Bio is pre-programmed with Bradford, Lowry, Biuret, Pierce 660 and BCA methods for protein concentration. Purified proteins can be...
Open the catalog to page 11Proteins Measurement modes Purified proteins at 280nm and Warburg-Christian, Protein Assays (Pierce 660, BCA, Bradford, Lowry, Biuret) 600nm optical density reading cells/ml Other Beam height Light source Results memory Removable media Outputs Power Size (w x d x h) Weight Warranty 15mm Xenon lamp Limited by attached mass storage device USB (supplied) USB x 2 12V DC, 3.8A 212 x 422 x 120mm 2.8kg 2 years including the xenon lamp
Open the catalog to page 12UNPACKING Remove the spectrophotometer from the packaging and ensure the following items are included: 3. Mains Power leads UK plug (M7817UK), EU (M7817X6) and US (M7817X1) 1. Model Genova Bio spectrophotometer (720 601) INSTALLATION The Genova Bio is supplied ready to use. The unit should be placed on a clean flat surface which is free from drafts and vibrations. Do not position the unit so that it is difficult to access the ON/OFF switch. Do not position the product so that it is difficult to disconnect from the mains supply using the mains plug. The mains outlet socket used should be...
Open the catalog to page 13All Jenway catalogs and technical brochures
-
GENOVA BIO AND TRAYCELL
4 Pages
-
Masterflex®
2 Pages
-
L/S® Digital Drives
2 Pages
-
pH Buffers
1 Pages
-
Bench pH Meter Accessories
5 Pages
-
pH Electrodes
5 Pages
-
3520
1 Pages
-
3510
1 Pages
-
Fluorimetry Cuvettes
1 Pages
-
Fluorimeter Filters
1 Pages
-
62 Series Fluorimeters
8 Pages
-
Colorimeter Accessories
2 Pages
-
6051 Bench Colorimeter
2 Pages
-
Conductivity Standards
2 Pages
-
9500 Bench DO2 Meter
1 Pages
-
Spectrophotometer Summary
2 Pages
-
Genova Plus Brochure
4 Pages
-
72 Series Spectrophotometers
8 Pages
-
73 Series Spectrophotometers
8 Pages
-
Jenway Catalogue 2009
97 Pages
-
63 Series Spectrophotometers
4 Pages
-
Flame Photometers
2 Pages
-
6051 Colorimeter
2 Pages
-
Jenway Catalogue 2012
104 Pages
-
Genova Plus
4 Pages
-
Genova Nano
4 Pages
-
PFP7
1 Pages
-
6850 Spectrophotometer
4 Pages
-
73 Series Brochure
8 Pages
-
PFP7/C
1 Pages
-
7305
1 Pages
-
6305
1 Pages
-
6300 and 6320D
1 Pages
-
9500
1 Pages
-
3505
1 Pages
-
4520
1 Pages
-
4510
1 Pages
-
430 Conductivity/pH Meter
1 Pages
Archived catalogs
-
6800 Spectrophotometer
2 Pages
-
67 Series Spectrophotometers
8 Pages
-
970
1 Pages
-
3345 Bench Ion Mete
1 Pages
-
3205 Portable Ion/pH Meter
1 Pages
-
470 Conductivity/TDS Meter
1 Pages
-
6051
2 Pages
-
6 2 Series Fluorimeters
8 Pages