Warm Care + Moisturizing Care Technical parameters: ‘Power supply: 100-240 Vac, 50-601Iz *Screen: 7-inch high-definition color touch screen *Dual channel: equipped with dual channel heating and pressure chamber and dual channel heating tube Dual heating function: pre heating of the heating chamber, real-time heating, and heating tube wrapping heating *Temperature adjustment range: 28.0-41.0 °C, witha step of 0.1 °C Pressure regulation range: 0-300mmHg, step by ImmHe *Multiple temperature protection: high-temperature, ultra-mild and low-temperature protection for the heating chamber, infrared Heating and pressure chamber temperature exceeding heating tube high temperature, over temperature, and low temperature protection *Multiple pressure protection: equipped with overvoltage protection, overpressure protection, and undervoltage protection The blood transfusion infusion heating and pressurization device is mainly suitable for *Drip rate detection: equipped with real-time drip rate detection function *Bubble detection: equipped with bubble detection function: after detecting bubbles, turn off infusion and prompt anesthesia departments, operating rooms, emergency departments, trauma centers, ICUs, obstetrics and gynecology, transfusion departments, ambulances, and field 7-inch touch screen with independent control for various functions | "Empty bottle detection: equipped with empty bottle detection function: after detecting an empty bottle, turn off the infusion and prompt “Infrared temperature detection function: Real time detection of liquid temperature, with active stop heating and protection prompt function *Lock fluid function: can automatically and manually lock fluid emergency situations. It can quickly heat and pressurize blood and medication for realizes continuous heating and rapid Liquid detection device Drip rate detection infusion. The heating and pressure chamber infusion, combined tube to achieve dual heating, ensuring the Infrared temperature heating effect of rapid blood transfusion Automatic locking fluid “Intelligent mode: Quick selection function for blood transfusion, infusion, and flushing “Intelligent control: One click start and stop function Alarm testing function: Real simulation alarm testing, with a maximum of 16 test items Alarm log: The system has an alarm log function, which facilitates maintenance personnel to trace the usage status Heating tube: 5 length sizes available *Practicality: Equipped with timer, screensaver, note reminder, electronic graphic and text manual function Lifespan: The product is valid for 10 years of use *Optional expansion: built-in rechargeable lithium battery and infusion. At the same time, the cabin is heated and pressurized, and the heating tube heating can be independently controlled . The dual channel design can be freely Secondary heating tube combined, suitable for various clinical Two heating chambers, two heating tubes, liquid detection device chamber, one heating tube, liquid detection device Two heating chambers, two heating tubes, liquid detection device, built-in battery One heating chamber, one heating tube, liquid detection device, built-in battery X There are multiple specifications available for selection Clinical Guidelines Product advantages PRODUCT FEATURES “The heating chamber and heating tube are double heated: The heating chamber can be pre heated or heated in real time, and the heating tube is wrapped throughout the heating process. Double heating ensures heating effect Dual channel heating and pressurization for multiple purposes: Both heating and pressurization are dual channels that can be used alone or simultaneously, achieving multiple uses for one machine “Liquid detection ensuring safety Drip rate detection: Drip rate is displayed in real-time on the main interface, with precise speed regulation Bubble and empty bottle detection: equipped with bubble and empty bottle detection function, after detecting bubbles or empty bottles, turn off infusion and prompt Infrared temperature detection function: Real time detection of liquid temperature, with active stop heating and heating protection prompt function *7-inch touch screen intelligent and convenient: 7-inch high-definition color touch screen, information display, touch operation, one click direct access Built in battery for easy transportation: Built in rechargeable lithium battery for use in transportation, first aid, and other scenarios “No need for consumables, save costs: No need for any consumables, the product has a service life of up to 10 years, a long lifespan, and saves costs “High Safety: Equipped with multiple temperature protection prompts, multiple pressure protection prompts, and 16 built-in simulation protection tests to ensure the safe operation of the equipment The National Anesthesiology Professional Metical Qualty Control hdcators (2022 ion propose active insulation assessmertindcators, inc ung ob opareve temperature and bicod protection / Active intraoperative insulation rate (AQI-AWR-08) *The incidence of hypothermia during PACU admission (AQI-IHP-17) *The incidence of hypothermia during surgical anesthesia (AQI-IHT-10) The Expert Consensus on the Prevention and Treatment of Hypothermia n Perioperative Patients (2017 Edition) proposes the principle of intraoperative insulation for the prevention a treatment of hypothermia during the perioperative period: Infusion of liquids and refrigerated blood products exceeding 500ml requires the use of an infusion heater to 37 ‘C_ before infusion [35-37] ll abdominal lavage fluids are recommended to be heated to 3-4'C before use The equipment, facilities, and consumables management requirements in the "Consensus of Anesthesiology Quality Control Experts" (2021), as well as the recommended levels of equipment in different locations Equipment and facil Temperatize monitoring end insulation preparation room/induction PACU AICU
Open the catalog to page 18 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page