Product Overview
This document provides detailed information about disposable endoscope linear cutting staplers and components, designed for resection, transection, and anastomosis of lung and bronchial tissues, stomach, and intestine in both open and endoscopic surgeries.
Device Body Parameters
The devices are available in various models with sleeve lengths ranging from 60mm to 255mm and a consistent diameter of 12.4mm. Models include CN-ED12-S, CN-ED12T-S, CN-ED12-C, CN-ED12T-C, CN-ED12-L, and CN-ED12T-L.
Cutting Component Parameters
Three main types of cutting components are detailed: CN-CCR, CN-CCRE, and CN-CCRC. Each type offers different models with varying suture lengths, reload colors, and staple heights. The models are color-coded for easy identification, with options including brown, purple, black, white, blue, yellow, and green.
Design and Features
The staplers feature a Gecko-Claw grasping technique and a Crocodile-Mouth design for effective tissue handling. The H-shaped cutter ensures uniform stapling and cutting. The ergonomic design includes a slip-proof, rubber-insulated handle for comfortable grip and a firing safety mechanism to prevent accidental firing.
Advantages of Stepped Cartridge
The stepped cartridge design allows for progressive tissue clamping, reducing damage while maintaining clamping force. The Gecko-Claw design minimizes tissue injury and spillage, while graduated-height staples ensure better blood supply and faster healing.
Contact Information
Jiangsu Channel Medical Co., Ltd. is the manufacturer, located in Kunshan, Jiangsu, China. For inquiries, contact via email at [email protected] or phone at +86-512-36857161.
See more

Catalog excerpts

CN-ED12 series (Conventional Model)-1

Indicated for resection, transection and anastomosis of lung and bronchial tissues, stomach and intestine in open or endoscopic surgery. Product Show Product Parameters 1、Device Body Parameters Sleeve length The slip-proof firing safety prevents empty component from firing. Disposable Endoscope Linear Cutting Staplers and Components With roller-like steering system and clear gear switch,the stapler is easy to manipulate. The "Drop-shaped" cartridge ensures precise staple formation. It is more convenient to loadand unload the slip-proof cutting components with a knob. The imported titanium staple ensures better anastomosis. The precisely processed"H"-shaped cutter ensures proximal and distal stapling and cutting are uniform. The component connected to the shaft is solid and safer. 2、Cutting Component Parameters 1)Parameters for CN-CCR Model Staple height Reload color Suture length Staple height Staple height Reload color Suture length Suture length Reload color The firing safety prevents firing of empty reload and increases surgical safety. The arched reset handle makes resetting grip cosier. The large slip-proof and rubber-insulated steering handle enables comfortable grip and makes gears more clear. Remark: Gecko-Claw grasping technique with Crocodile-Mouth design Remark: Gecko-Claw grasping technique Remark: Gecko-Claw Grasping tecnique CCRC30/45-W has undetachable Beak-Shaped metal guide while the others uses plastic guide Large steering handle Roller-like steering system Drop-shaped Cartridge Easy operation Manipulate with ease With"Gecko-Claw"grasping technique and surface supporting structure, the staple formation is more precise. Precise Staple Formation The five-step firing handle eases operation. 3、Advantages of Stepped Cartridge • Stepped cartridge design, progressive tissue clamping It’s convenient to evacuate fluids from both sides during closure and firing, and easy to compress tissues to proper thickness for stapling. The damages arising from squeezing is reduced without compromising the clamping force. • Graduated-height staples Staples with unequal heights guarantee better blood supply and faster healing, which means greater tissue adaptability. • Gecko-claw design Tissues can be held with less injury and spillage, and staple formation becomes more precise. The tissue grasping technique with"Crocodile-Mouth" structure can minimize tissue protrusion and facilitate effective cutting and stapling length. The ergonomic slip-proof and rubber-insulated handle make firing grip more comfortable. Jiangsu CHANNEL Medical Device Co. , Ltd. Tel:+ 86-512-36857161 Web:www.channel-mdi.com Email:[email protected] Add:Fourth Floor, G3, 999#, Qujia Road, Qiandeng Town, Kunshan, Jiang

 Open the catalog to page 1

All Jiangsu Channel Medical Device catalogs and technical brochures

  1. CN-TCI Series

    2  Pages

  2. CN-LCS Series

    2  Pages

  3. CN-LCD Series

    2  Pages

  4. CN-PPH Series

    2  Pages

  5. CN-CS Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.