Ventilator&Anesthesia Machine FuyouMed ADVANCED DESIGN & MONITORING TECHNICAL PARAMETERS PART OF ANESTHESIA MACHINE Large screen high-definition TFT wide viewing angle 10.1" Color LCD Touch Screen New interface design, reasonable layout and color matching Pressure-Time waveform, Flow-Time waveform display on the same screen Powerful monitoring and alarm functions Comprehensive respiratory mechanics monitoring allows you to fully grasp the patient's respiratory status HIGH-PRECISION VAPORIZER Vaporizer can support low flow anesthesia as low as 0.2L/min and large flow anesthesia up to 15L/min. Accurate output of concentrations under varying conditions of pressure, flow and temperature. Support Selectatec Mounting type and Cagemount compatible 4 Kinds of Vaporizer for Choice: Halothane, Enflurane, Isoflurane and Sevoflurane Fill-in type: Pouring • Main Body High-strength engineering plastic rack, light, beautiful and corrosion resistant Adult, Child • Flow Meter When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure<0.16±0.02Kpa, the flow of nitrous oxide would be cut off. • Flow Rate of Rapid Oxygen Supply • Low Oxygen Pressure Alarm There will be sound alarm when the oxygen pressure < 0.2MPa It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0 ~ 5 vol%. Among Halothane, Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer. • Respiratory Circuit Working mode: All-close, Semi-close, Semi-open • Respiratory Bellows Bellows for adults and children Equipped with LED illumination, easy for observation • ACGO Port With ACGO port to connect with T circuit or BAIN circuit for open-operation. • AGSS Port AGSS exhaust gas collection system can be installed. 10.4-inch High-definition TFT color LCD screen display VCV , PCV , SIMV , PSV, PSV+SIMV, CPAP PEEPx SIGH n standby > IP. IRV Tidal volume Rate SIMV rate Inspiratory trigger pressure Flow trigger sensitivity Pressure control Pressure limitation Pressure slope Flow rate setting Expiratory trigger sensitivity Time control SIGH Inspiratory platform Oxygen concentration 1.5 times the inspiratory time ( 60-120 adjustable) ♦ Parameters for ventilation monitoring Expired tidal volume, Inhale tidal volume, Minute Ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous breathing rate, l/E, peak pressure of airway, average pressure, PEEP, Inspiratory trigger pressure, inspiratory platform, oxygen concentration, battery capacity , pressure - time waveform, flow rate - time waveform, flow-volume loop, pressure -volume loop 4 Security Alarm System Oxygen concentration alarm INTEGRATED BREATHING CIRCUIT Airway pressure alarm minute ventilation volume alarm Tidal volume Respiratory rate Sustained high-pressure alarm Suffocation alarm Low pressure of Oxygen alarm upper limit setting range low limit setting range upper limit setting range low limit setting range upper limit setting range low limit setting range upper limit setting range low limit setting range upper limit setting range low limit setting range it will give alarm when stress have consistently been higher than 30 cmH20 Power alarm Intubation off alarm battery voltage alarm Integrated breathing circuit with APL valve, excellent tightness and safety. Made of special materials, resistant to corrosion and high temperature. Compact structure, no external pipelines, good mechanical compliance. Impeller sampling is used at the exhalation end to avoid inaccurate monitoring of tidal volume due to water vapor condensation. Drive bellows is not required to repalce when operating pediatric anesthesia. Large volume of C02 canister, single tank structure for more convenient in assembly. • Display Mode High-definition 10.1" TFT color LCD touch screen display, easy and convenient operation • Ventilation Mode IPPV, SIPPV, SIMV, PEEP,SIGH,MANUAL • Ventilation Function ACGO PORT With ACGO port to connect with T circuit or BAIN circuit for open-operation. Convenient for patients' oxygen inhalation and post-operative recovery. • Ventilation Parameters Tidal volume:50 ~ 1500 ml, Rate:2 ~ 99 bpm, SIMV rate:2 ~ 20bpm, I:E:2:1 ~ 1:8, Inspiratory trigger pressure: -10 ~ 20 cmH;0, PEEP:2 ~ 20 cmH;0, Pressure range:5 ~ 60 cmH20, SIGH:1.5 times the inspiratory time/100 times breath • Parameters For Ventilation Monitoring Tidal Volume, Ventilation Volume, IPPV Rate, SIMV Rate, I:E, Peak Pressure of Airway, Pressure-Time Waveform, Flow Rate-Time Waveform, PEEP, Inspiratory Trigger Pressure (Average Pressure, Fi02 Oxygen Concentration, Battery Level) • Power Supply Built-in Li Battery (Work at least for 8 hours) • Security Alarm System Oxygen Concentration Alarm: Upper limit setting range:21% ~ 99%,Low limit setting range:18%~80% Airway Pressure Alarm: Upper limit setting range:5~60 cmH 0,Low limit setting range:0~ 50cmH O Per-minute Ventilation Volume Alarm: Upper limit setting range:l ~ 20L/min,Low limit setting range: 0~19L/min Tidal Volume alarm: Upper limit setting range:100 ~ 1500ml,Low limit setting range 0~ 1400ml Sustained High Pressure Alarm: It will give alarm when stress have consistently been higher than 25 cmH O for 15s. Suffocation Alarm: It will give alarm when stress have consistently been higher than 10 cmH O and tidal volume is less than 120ml for 15s. Tube Escape Alarm: It will give alarm when stress have consistently been less than 2cmH .0 for 15s. Low Battery Level Alarm: It will give alarm when battery level is less than 14±0.5V Negative Pressure Alarm: It will give alarm when airway stress has been less than lOcmH.O for Is. Mechanical Arms Bracket for Patient Monitor ETCO? monitoring
Open the catalog to page 11 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
4 Pages
1 Page
1 Page
2 Pages
3 Pages
12 Pages
7 Pages
2 Pages
15 Pages
24 Pages
4 Pages
5 Pages
2 Pages
6 Pages
1 Page
5 Pages
13 Pages
8 Pages
4 Pages
22 Pages
8 Pages
1 Page