HEARTROID CATALOG
12Pages

{{requestButtons}}

Catalog excerpts

HEARTROID CATALOG - 1

Osaka University Graduate School of Medicine Department of Cardiovascular Medicine Keita OKAYAMA, MD, PhD Yasuhiro ICHIBORI, MD, PhD Isamu MIZOTE, MD, PhD Yasumasa TSUKAMOTO, MD, PhD Masaki AWATA, MD Hlroya MIZUNO, MD, PhD, FESC Shinsuke NANTO, MD, PhD, FACC Yasushi SAKATA, MD. PhD, FACC, FESC, FJCC -Contact details for inquiries JMC Corporation Sumitomofudosan Shinyokohama Bldg. IF, 2-5-5, S hi nyokohama,Kohoku-ku,Yokohama-shi, Kanagawa, 222-0033, Japan Tel +81-45-477-5757 Fax +81-45-471-5270 Mail jmcltd@jmc-rp.co.jp -Joint research and development FYC FUYO CORPORATION This product was developed through the national project “R&D for medical devices”, supported by the Japan Agency for Medical Research and Development (AMED). 20030000 HEARTROID® medical training system HEARTROID

Open the catalog to page 1
HEARTROID CATALOG - 2

MEDICAL TRAINING SYSTEM HEARTROID® Do practice not on a patient but ... “HEARTROID” “HEARTROID” is a training system with a heart model and a pulsatile pump for interventional cardiologists and medical students. contents Train anywhere X-ray compatible In the cath lab, office, conference hands-on and anywhere Practical training under X-ray fluoroscopy Fast & Easy preparation Ready-to-use in just a few minutes without any technical knowledge Compact design Inflight carry-on baggage compatible 4-8 CORONARY ■ PCI Model ■ CTO Model ■ BIF Model ■ CABG Model ■ CAG Model -Detachable Disease parts...

Open the catalog to page 2
HEARTROID CATALOG - 3

CORONARY STRUCTURE CORONARY HEARTROID coronary series can facilitate many scenarios including simple CAG, PCI, Atherectomy, ACS, CTO, Bifucation strategy and some bail-out procedures under angiography visualized by camera and X-ray fluorosopy. Product specifications can be customized and are subject to change without notice. Please contact JMC for details. 4. Tubes with Sheath Number of tubes : 2 (6-8Fr) 5. Lubricant I fl. 0Z. (lasts for 20 coatings) 6. Hoses I. Heart Model for Coronary A heart model suitable for practical training in CAG and PCI under X-ray fluoroscopy in the cath lab....

Open the catalog to page 3
HEARTROID CATALOG - 4

CORONARY STRUCTURE High-end Class I Compatible Operating procedure I Rotablation DCA Vascular rupture CTO High-end Class I Compatible Operating procedure I CAG IVUS / OCT FFR Stenting Rotablation Bifurcation This is a chronic total occlusion (CTO) disease model. It features multiple collateral channels between LAD and RCA (including septal branch and apex routes), and between LCX and RCA (including AV groove and apex routes). The LAD, LCX and RCA have their own pockets, so that if the CTO vessel part is set in the RCA pocket, both the antegrade approach from RCA and the retrograde approach...

Open the catalog to page 4
HEARTROID CATALOG - 5

CORONARY STRUCTURE High-end Class I Compatible Operating procedure I CAG CABG ACS IVUS / OCT Disease parts (detachable & disporsable) Soft plaque Concentric Calc <Q) 75% stenosis with soft plaque suitable for direct stenting. o 75% stenosis with concentric calcification suitable for rotablation. 9 75% stenosis with eccentric calcification suitable for directional coronary atherectomy. Q> For bail-out scenario “Coronary Perforation” o 100% total occlusion easy to pass Compatible with CTO Models only O 100% total occlusion. (Hardness: level I to 5) This is a triple vessel disease model with a...

Open the catalog to page 5
HEARTROID CATALOG - 6

STRUCTURE ABLATION TAVI Model Basic Set Product specifications can be customized and are subject to change without notice. Please contact JMC for details. I. Heart Model for TAVI Heart model suitable for practical training in TAVI under X-ray fluoroscopy in the cath lab. 3. Special Tank for TAVI 5. Tubes with Sheath Number of tubes : I (6Fr) 6. Lubricant I fl. OZ. (lasts for 20 coatings) 7. Hoses 4. Special Pulsatile Pump for TAVI HEARTROID TAVI model facilitates technical training for TAVI (Transcatheter Aortic Valve Implantation), a novel therapy for aortic valve stenosis. With a...

Open the catalog to page 6
HEARTROID CATALOG - 7

LAA Closure Model HEARTROID LAA closure model facilitates training for the LAA (left atrial appendage) closure procedure, a catheter-based operation for patients at risk of stroke due to atrial fibrillation. Guided by echocardiography, the delivery catheter can be inserted through the atrial septum and the occluder can be deployed in the LAA. Blood flow from the left atrium to the left ventricle is simulated, so the location of the occluder can be confirmed by X-ray fluoroscopy during the procedure. Wind Sock model Chicken Wing model Broccoli model Basic Set Product specifications can be...

Open the catalog to page 7
HEARTROID CATALOG - 8

Ablation Model PVI Model "m HEARTROID Ablation model facilitates technical training for catheter manipulation and 3D mapping, which are basic skills required for catheter ablation. With this model, the Brockenbrough Method (atrial septal puncture) guided by ICE (intracardiac echocardiography) can also be simulated. The model is appropriate for both the internal jugular and femoral vein approach. HEARTROID PVI model facilitates simulated training of a pulmonary vein isolation procedure, with or without X-ray visualization. During cryoballoon catheter ablation, the operator is able to check...

Open the catalog to page 8
HEARTROID CATALOG - 9

ABLATION PERIPHERAL Basic Set Product specifications can be customized and are subject to change without notice. Please contact JMC for details. Basic Set Product specifications can be customized and are subject to change without notice. Please contact JMC for details. 4. Tubes with Sheath Number of tubes : 2 (8Fr) 5. Lubricant I fl. OZ. (lasts for 20 coatings) 6. Hoses 4. Tubes with Sheath 5. Lubricant I fl. OZ. (lasts for 20 coatings) I. EVT Model Peripheral vessel model. Major arteries from terminal aorta to plantar arch with some pockets capable of setting removable disease parts. 2....

Open the catalog to page 9
HEARTROID CATALOG - 10

Myocardial Biopsy Model With this model, the myocardial biopsy procedure can be simulated under X-ray fluoroscopy, similar to the set-up in a real cath lab. The transparent heart model enables one to practice the procedure by confirming the direction of the sheath and forceps through both an X-ray image and a camera image. As the material used to simulate the ventricular septum is different from that of the ventricular free wall, it is easy to confirm whether the tissue was removed from the appropriate area after the procedure. Using the X-ray image, it is possible to determine if the...

Open the catalog to page 10