Blood Management System

Blood Management System
1 / 24 PagesView full catalog

Blood Management System

Product catalog summary
Overview
JMS has been a manufacturer of blood management products since 1969, emphasizing reliability and high quality. Their products are certified under the EN ISO13485 Quality System, ensuring compliance with stringent standards for blood banks and transfusion services.
Product Range
JMS provides a wide array of blood management systems, including blood bags with enhanced safety features, blood banking accessories, and various product configurations such as the CPD-SAGM System and T-BEXS.
Key Features
  • Convenience: Features like integrated blood sampling ports and reusable systems.
  • Reliability: Contamination-free sampling storage containers.
  • Safety: Needle protectors to prevent injuries.
CPD-SAGM System
This system includes a primary bag with CPD anticoagulant solution and a satellite bag with SAGM solution, allowing for 42-day RBC storage and maintaining an 80% post-transfusion RBC survival rate. It also supports larger plasma collection and platelet storage for up to 5 days.
T-BEXS (CPD-SAGM)
Designed for efficient blood component separation using automatic extractors, enhancing post-centrifugation separation efficacy.
Whole Blood In-line Leuko-Filtration System
This system reduces leukocyte contamination, minimizing side effects and meeting EU and AABB standards for safe handling.
Whole Blood In-line Filter
Ensures high plasma yield and efficient leukocyte removal, maintaining excellent red cell viability for 42 days.
Dockable Red Cell Leuko-Filtration System
A sterile disposable device for reducing leukocytes from red blood cells, ensuring safe and effective collection.
Cord Blood Bag Collection Set
Designed for collecting umbilical cord blood with minimal contamination risk, used in allergenic transplantation.
Autologous Bag
Used for storing a patient's own blood for autotransfusion, enhancing safety during surgeries.
Cellaid Serum Collection Bag
Contains platelet activation beads for serum preparation, rich in growth factors, in a closed system to reduce contamination risk.
Platelet Storage Bag
Utilizes UPX-80 material for high gas permeability, maintaining platelet viability for at least 5 days.
Blood Bag Configurations
JMS offers single, double, triple, and quadruple blood bags for various blood component separations, each designed with specific features for optimal performance and safety.
See more

Catalog excerpts

Blood Management System-1

Blood Management System

 Open the catalog to page 1
Blood Management System-2

Caring for your health JMS designs up-to-date blood management products with our patients and donors in mind. JMS started manufacturing blood bags in 1969 and have now over four decades of extensive and relevant expertise to meet the challenges presented in research, development and production of medical devices for blood transfusion applications. Blood bags manufactured by JMS have a long and laudable reputation for reliability, superior product quality and assurance. Certified under EN ISO13485 Quality System, our fastidious production practices and high standards of quality control and measures...

 Open the catalog to page 2
Blood Management System-3

Blood Management System About JMS Safety Features T-BEXS (CPD-SAGM) Whole Blood In-line Filter Cord Blood Bag Collection Set Enhanced Features Platelet Storage Bag Blood Banking Accessories Content CPD-SAGM System Whole Blood In-line Leuko-Filtration System Dockable Red Cell Leuko-Filtration System Autologous Bag Cellaid Serum Collection Bag Product Conf igurations

 Open the catalog to page 3
Blood Management System-4

Safe and effective blood transfusion Safety First. Our concern is not only to guarantee high quality of the blood components but also to provide maximum safety during blood donation and sample collection. Convenience JMS Integrated Blood Sampling Port Closed system & reusable blood sampling with vacuum tube Option to have lid Reliability JMS Blood Sampling Bag Storage container for convenient and contamination free sampling Volume of diverted blood could be used for laboratory testing Safety JMS Needle Protector Anti-stick device to provide healthcare workers and end -users maximum protection...

 Open the catalog to page 4
Blood Management System-5

CPD-SAGM SYSTEM The system consists of a primary bag containing anticoagulant CPD solution and one satellite bag containing SAGM (saline-adenine-glucose-mannitol) red cell preservation solution. This additive solution maintains red blood cell (RBC) viability and lowers the hematocrit of the RBC unit. Consequently JMS CPD-SAGM system can store RBCs for 42 days while maintaining 80% of post transfusion RBC survival rate. This additive-solution system also allows larger volume of plasma to be collected. The removal of buffy coat and preparation of platelet concentrates from the buffy coat are easily...

 Open the catalog to page 5
Blood Management System-6

T-BEXS (CPD-SAGM) JMS T-BEX (Top and Bottom Extraction) System provides greater efficacy in the separation of blood components after centrifugation process. It is common for blood banks to use automatic processing machines to standardize and save manual labour in the extraction of quality Red Blood Cell, Plasma and Platelets from collected Whole Blood. This system focuses on the use of the primary bag with Top and Bottom outlet ports which are mounted on the extractor unit after centrifuge. Using a single press operation, the Platelet-Poor-Plasma is transferred to the upper transfer bag and the...

 Open the catalog to page 6
Blood Management System-7

WHOLE BLOOD IN-LINE LEUKO-FILTRATION SYSTEM The world-wide demand for leuko-reduced whole blood has encouraged JMS to develop blood bag systems that meet the regulatory guidelines and strict requirements of blood banks especially in Europe and the US markets. Reduction of leukocyte contamination in blood components is important to minimize various side effects such as non-hemolytic febrile transfusion reactions, transmission of leukocyte-borne virus and prevention of HLA alloimmunization and platelet refractoriness. In line with our commitment to continuous improvement and safe patient care,...

 Open the catalog to page 7
Blood Management System-8

WHOLE BLOOD IN-LINE FILTER Rigorous and advanced tests in our JMS research and development institutes as well as in practical use of blood banks have shown that the LEUKOSEP In-line Filter for whole blood combined with our well-established blood bag systems provide a high yield of plasma. This includes a yield of Factor VIII, excellent viability of red cells and removal efficiency of leukocytes. Our certified production system includes strict quality assurance, guaranteed with a continuous high and consistent quality level. The steam sterilization of the complete system and efficient coiling...

 Open the catalog to page 8
Blood Management System-9

DOCKABLE RED CELL LEUKO-FILTRATION SYSTEM JMS Leukoreduction and Storage Set for Red Cells is a sterile disposable device intended for reducing leukocytes from a unit of red blood cell. This design provides a safe, effective and convenient collection of red cells coupled with high efficiency leukocyte filtration processing. State-of-the-art collection, filtration and storage User-friendly, safe and fast handling of systems Superb air venting system Tubing compatible with sterile device connection Application Red Cell Concentrate Volume Derived from 1 unit of 450 - 500ml +/- 10% Whole Blood Filter...

 Open the catalog to page 9
Blood Management System-10

CORD BLOOD BAG COLLECTION SET Cord Blood Bags are designed to collect the umbilical cord blood (also known as placental blood) after the birth of the baby, within the shortest time and minimal risk of contamination. The clinical use of the cord blood is allergenic transplantation in patients suffering from severe blood diseases such as leukemia, lymphoma, etc. Tubing compatible with sterile device connection Specially tailored volume of anticoagulant Option to have double needles and integrated blood sampling port / sampling bag Ease of cleaning and water tolerance with polymeric labels Direct...

 Open the catalog to page 10
Blood Management System-11

Auto-Transfusion is a process where patient receives his or her own blood instead of donor blood. This is a common pratice for joint replacement surgeries and can be performed before, during or after surgeries. During autologous blood donation patient donates his or her blood for own use, this process can commence up to 5 weeks before surgery, which will be stored and reinfused as needed during or after the surgery. As own blood is receptive to the body, it is an extremely safe way to help the patient in the recovery process. JMS Autologous Bag is specially designed and used to store patient’s...

 Open the catalog to page 11
Blood Management System-12

Patient and Donor Safety is o With a renowned reputation for full co comfort. JMS Blood Bags are manufac including collection, separation, prese Needle Bevel Non-Stick Tubing The oval slit is profiled to tip’s geometry that has much smaller step for minimal tissue shaving and blood seepage during needle insertion. Designed with polymeric tamper proof label, registered in ICCBBA and licensed to use ISBT 128 Bar Code for systematic identification. Compatible with universal tube sealer & sterile connecting device. Unique printed segment number for each unit. Rounded corners avoid friction, sm of...

 Open the catalog to page 12

All JMS North America Corporation catalogs and technical brochures

  1. SP-500

    2  Pages

  2. OT-701

    2  Pages

  3. NEOSHIELD®

    2  Pages

  4. BasicLine

    4  Pages

  5. SDS-50

    2  Pages

  6. SysLoc® MINI

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.