1. Catalogs
  2. Johnson & Johnson Vision
  3. COMPACT INTUITIV System

COMPACT INTUITIV System

COMPACT INTUITIV System
1 / 151 PagesView full catalog

COMPACT INTUITIV System

Product catalog summary
Introduction
The document provides comprehensive information on the COMPACT INTUITIV System, a modular ophthalmic microsurgical system designed for anterior segment surgical procedures, specifically phacoemulsification. It includes details on system enhancements available through Johnson & Johnson Surgical Vision, Inc.
Phacoemulsification
Phacoemulsification is a method for cataract removal using ultrasonic emulsification, offering advantages such as greater intraoperative control, smaller incisions, reduced infection risk, and quicker recovery compared to traditional methods.
System Components and Setup
The manual details the system components, setup procedures, and safety precautions. It includes instructions for system setup, power connections, and the use of single-use packs.
Operating Modes and Safety
The system offers various operating modes with specific safety precautions and warnings to ensure proper use and prevent hazards.
System Maintenance
Guidelines for cleaning, sterilization, and maintenance of the system and its components are provided to ensure longevity and optimal performance.
Troubleshooting and Diagnostics
The manual includes troubleshooting tips, diagnostics, and procedures for common user-correctable problems, ensuring users can address issues efficiently.
Specifications
Detailed specifications cover physical, electrical, and environmental aspects of the system, along with specific parameters for diathermy, phacoemulsification, and vitrectomy.
Reordering and Warranty
Information on reordering accessories and parts, along with warranty and maintenance details, is provided to support ongoing system use.
WHITESTAR Technology
This technology delivers finely modulated pulses of energy with brief cooling periods, enhancing ultrasound cutting efficiency while minimizing energy introduction into the eye, thus reducing thermal damage risks.
Pulse Shaping
Pulse Shaping allows for adjustable energy pulses, enhancing cutting efficiency and followability with reduced energy input.
Occlusion Mode Phaco
This mode regulates vacuum rise time post-occlusion and allows independent control of aspiration rates for occluded and unoccluded needles.
Chamber Stabilization Environment (CASE)
CASE is a vacuum monitoring system that adjusts maximum allowable vacuum levels to prevent post-occlusion surges, enhancing control and efficiency.
Advanced Fluidics System
The system features a closed fluidics system for intraoperative control, maximizing safety and minimizing biohazard risks.
Accessories
The system includes a lightweight phaco handpiece with efficient aspiration channels, the ELLIPS FX handpiece for varied movement, a foot pedal for mode control, and a wireless remote for surgical settings adjustment.
System Cart and IV Pole
The cart is stable with storage options, and the automated IV pole allows for sterile adjustment of bottle height.
Console and User Interface
The system features an easy-to-read screen displaying modes, settings, and system status, with distinct screens for each surgical mode.
Safety Precautions
Key precautions include avoiding extension cords, ensuring proper ventilation, using recommended parts, and handling handpieces with care to prevent damage or contamination.
Handling Emergencies
Guidelines are provided for power failures and ensuring adequate irrigation during phacoemulsification to prevent tissue damage.
System Setup Overview
The COMPACT INTUITIV System setup for surgery involves several key steps, including connecting the power cord and foot pedal, attaching the IV Pole connector, and installing the Single-Use Pack.
Single-Use Pack Installation
The OPO80 Single-Use Pack is disposable and should be installed following specific steps to ensure proper fluid management during procedures.
Handpiece Setup
Instructions for setting up various handpieces include ensuring sterility and checking for damage.
System Check-Out
Before surgery, verify system operation by testing I/A and Phaco functions and checking Diathermy and Vitrectomy modes.
System Settings
Configure system settings via the setup screen, including running a self-test and calibrating the touch screen.
Foot Pedal Configuration
The document outlines the steps to configure foot pedal switches, allowing users to adjust the threshold for each pitch zone and assign functionalities.
Sound and Display Settings
Sound settings are customizable for each surgeon, and display brightness can be adjusted.
Reflux and Vent Modes
Reflux allows controlled backflow of fluid, and venting alleviates residual vacuum when the foot pedal is released.
Program Settings
The system allows the creation of up to eight programs per surgeon, with options to add, import, export, lock, edit, or remove programs.
Diathermy Settings
Diathermy power settings range from 5% to 100%, with options for linear, panel, or burst power delivery.
Phacoemulsification Settings
Phaco settings include four submodes with adjustable parameters for aspiration, vacuum, and power.
Vitrectomy Procedures
The document outlines the steps for using the vitrectomy mode, emphasizing the importance of priming the vitrectomy handpiece.
End Case Procedures
The 'End Case' function allows users to terminate a surgical case, with options to save or discard changes made to program settings.
Cleaning and Sterilization
Detailed instructions are provided for cleaning and sterilizing various handpieces and components of the system.
System Shutdown
A step-by-step guide is provided for shutting down the system safely.
Troubleshooting and Diagnostics
The document includes a comprehensive troubleshooting section for common issues and provides corrective actions for each problem.
Warranty and Maintenance
The COMPACT INTUITIV System is warranted for 12 months from installation, covering defects in materials and workmanship.
Specifications
Detailed dimensions, weight, and power requirements for the console, foot pedal, and IV pole are provided.
Accessories and Parts Reordering
A comprehensive list of parts and accessories for the COMPACT INTUITIV System is provided, including part numbers for reordering.
See more

Catalog excerpts

COMPACT INTUITIV System-1

COMPACT INTUITIV System OPERATOR’S MANUAL 0130-0084 Rev. A 0218

 Open the catalog to page 1
COMPACT INTUITIV System-2

AMO, COMPACT INTUITIV, SOVEREIGN, WHITESTAR, ELLIPS, the ELLIPS logo, LAMINAR, and PHACOFIT are trademarks of Johnson & Johnson Surgical Vision, Inc. SOLO and DUET are trademarks of MicroSurgical Technology, Inc. BLUETOOTH is a trademark of Bluetooth SIG, Inc. All other brand names, products, and company names mentioned in this document are the trade name, service mark, or trademarks of their respective owners. In accordance with: • IEC/EN 60601-1 2007 Johnson & Johnson Surgical Vision, Inc. 1700 E. St. Andrew Place Santa Ana, CA, USA 92705 1-877-266-4543 (USA) Product of USA AMO Ireland Block...

 Open the catalog to page 2
COMPACT INTUITIV System-3

COMPACT INTUITIV System Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 About Phacoemulsification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Indications for Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 COMPACT INTUITIV System . . . . . . . ....

 Open the catalog to page 3
COMPACT INTUITIV System-4

COMPACT INTUITIV System Foot Pedal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 Three Button Foot Pedal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 Four Button Foot Pedal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 Sounds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13 Display Adjustment . . . . . ....

 Open the catalog to page 4
COMPACT INTUITIV System-5

COMPACT INTUITIV System Warranty and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1 Warranty Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1 Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . ....

 Open the catalog to page 5
COMPACT INTUITIV System-6

COMPACT INTUITIV System About this Manual About Phacoemulsification COMPACT INTUITIV System Advanced Fluidics System Accessories Safety Precautions Warnings Symbol Definitions

 Open the catalog to page 6
COMPACT INTUITIV System-7

COMPACT INTUITIV System About this Manual 1 • Introduction This manual includes information about the design of the COMPACT INTUITIV System for anterior segment (phacoemulsification) surgical procedures. This manual includes information about optional system enhancements. Your Johnson & Johnson Surgical Vision, Inc. representative can confirm the availability of these features for your system configuration in your area. About Phacoemulsification Over forty years ago, Doctor Charles Kelman conceived and developed phacoemulsification, a method of cataract removal by use of ultrasonic emulsification...

 Open the catalog to page 7
COMPACT INTUITIV System-8

COMPACT INTUITIV System Occlusion Mode Phaco You can use the Occlusion Mode Phaco to regulate the vacuum rise time that follows the occlusion of the phaco tip, without limiting the choice of aspiration rate through an unoccluded needle. In order to independently control the aspiration rate and the vacuum rise time, it is possible to have a different aspiration rate for an occluded needle and an unoccluded needle. You can use Occlusion Mode Phaco to regulate ultrasound power modulation. You can program the power modulation of the phaco handpiece (continuous, pulse, burst, etc.) to automatically...

 Open the catalog to page 8
COMPACT INTUITIV System-9

COMPACT INTUITIV System ELLIPS FX Handpiece The ELLIPS FX phaco handpiece is available for use with the COMPACT INTUITIV System. The ELLIPS FX handpiece provides both longitudinal and transversal movement. You can use the handpiece with a straight tip or a curved tip. Foot Pedal The operating modes (Diathermy, I/A, Phaco, and Vitrectomy) are controlled by the foot pedal. You can save the degree of travel for each foot pedal position for each surgeon/procedure. The foot pedal design offers control through the use of increased linearity with the foot pedal movement. The design provides uniform...

 Open the catalog to page 9
COMPACT INTUITIV System-10

COMPACT INTUITIV System 1 • Introduction Each surgical mode and submode has its own distinct screen: • Diathermy • Phaco • Irrigation/Aspiration • Vitrectomy Figure 1.1 – Phaco Screen Additionally, there are screens or sub-screens for: • Prime/Tune • End Case • Program Settings • Surgeon Settings • System Setup Prime/Tune Before the start of each surgical case, the system requires that you run prime or prime/tune. The prime mode incorporates the function of clearing the tubing of air. The prime mode then fills the tubing and completes the fluid aspiration check and the vacuum check. The tune...

 Open the catalog to page 10
COMPACT INTUITIV System-11

COMPACT INTUITIV System Continuous Irrigation Continuous Irrigation is immediately available by way of the touch screen. Surgeon control of continuous irrigation with the foot pedal is an available setting for the foot pedal. You can use continuous irrigation to fill cups prior to prime/tune. You can use the cup fill feature in place of continuous irrigation when you fill a cup. The cup fill feature is only available from the prime/tune screen. (See “Prime/Tune” on page 6-2. for detailed information.) Programmable Operating Parameters The COMPACT INTUITIV System is programmable through the GUI....

 Open the catalog to page 11
COMPACT INTUITIV System-12

COMPACT INTUITIV System Irrigation/Aspiration (I/A) The Irrigation and Aspiration mode allows for controlled aspiration of cortical material from the eye, while maintaining intraocular stability by replacing the aspirated material with the irrigation solution. A peristaltic pump provides a predictable and stable aspiration rate. You can achieve complete control with “Aspiration” and “Vacuum”. Note: The vacuum units are available in either mmHg or kPa. To set the vacuum units go to System Setup and select Vacuum Units. Irrigation is gravity-fed. You can regulate the gravity-fed irrigation pressure...

 Open the catalog to page 12