i Design Advanced WaveScan Studio System YOUR SMARTEST CHOICE THE BRAIN POWERING THE iLAS/K® TECHNOLOGY SUITE INDICATIONS: The STAR S4IR® Excimer Laser System and iDESIGN® Advanced WaveScan Studio System are indicated for wavefront-guided laser-assisted in situ keratomileusis (LASIK) in patients with myopia as measured by iDESIGN® Advanced WaveScan Studio System up to -11.00 D spherical equivalent, with up to -5.00 D cylinder; with agreement between manifest refraction (adjusted for optical infinity) and iDESIGN® Advanced WaveScan Studio System refraction of 1) spherical equivalent: magnitude of the difference is less than 0.625 D, and 2) cylinder: magnitude of the difference is less than or equal to 0.5 D; and with patients 18 years of age or older, and with refractive stability (a change of <1.0 D in sphere or cylinder for a minimum of 12 months prior to surgery). For safety information, please see inside.

 Open the catalog to page 1
iDesign - Advanced WaveScan Studio System-2

MORE BRAIN POWER IN YOUR SURGERY 5 MEASUREMENTS IN 1 CAPTURE SEQUENCE 1 Wavefront aberrometry 2 Wavefront refraction 3 Corneal topography 4 Keratometry 5 Pupillometry EASY-TO-USE INTERFACE WITH ALIGNMENT AIDS AND ON-SCREEN TOOLS Screen is a simulated image SEAMLESSLY INTEGRATES WITH THE STAR S4 IR® EXCIMER LASER

 Open the catalog to page 2
iDesign - Advanced WaveScan Studio System-3

WITH A HIGH-DEFINITION HARTMANN-SHACK WAVEFRONT SENSOR* Standard Wavefront iDESIGN® System High-Definition Wavefront Offering outstanding accuracy and ability to measure complex wavefronts • p to 1,257 micro-refractions over a 7 mm pupil U • X the dynamic range* 3 • aptures more ocular aberrations unique to every eye* C *As compared to the Hartmann-Shack sensor in the WaveScan WaveFront® Sy

 Open the catalog to page 3
iDesign - Advanced WaveScan Studio System-4

“The iDESIGN ® System gives us a mechanism to capture the entire wavefront in our LASIK patients. It really hits the target in terms of astigmatism and then allows that to be translated to the patient’s treatment plan and results.” –JAY S. PEPOSE, MD

 Open the catalog to page 4
iDesign - Advanced WaveScan Studio System-5

4^5 D Measure and treat higher level of astigmatism for myopes -11 D SE with up to - 5 D cylinder 4.0—9.5mm Capture measurements on a wide range of pupil sizes

 Open the catalog to page 5
iDesign - Advanced WaveScan Studio System-6

At six months after surgery, patients reported significant improvements in ALL measures of quality of vision and visual function (without retreatment)1 • 99% of study participants stated they were not limited in active sports or outdoor activities • 99% experienced little or no difficulty with the clarity of their vision • 97% of study participants were satisfied with their vision • 93% of study participants stated they had little to no difficulty driving at night • Majority of study participants achieved 20/16 or better visual acuity ~90% of eyes had improvements or no change in contrast sensitivity...

 Open the catalog to page 6
iDesign - Advanced WaveScan Studio System-7

“We have seen tremendous improvements in tightening the results that we get in terms of the percentages of eyes that reach 20/20 and ® now with the iDESIGN System, even better than 20/20 vision.”

 Open the catalog to page 7
iDesign - Advanced WaveScan Studio System-8

• Business Development o In-person and online education — practice-building tools and patient-marketing initiatives o Diagnosis and solutions to elevate practice performance • Clinical Training o On-site surgeon and technician training and support to help improve outcomes by maximizing team skills o Highly skilled application support team and renowned medical monitors — ongoing clinical consultation and analysis to enhance patient outcomes • Field Service Support o Multiple service plans to meet your practice needs — so you can be confident in your system’s performance o 10-time recipient of...

 Open the catalog to page 8
iDesign - Advanced WaveScan Studio System-9

MAKE THE iDESIGN SYSTEM YOUR SMARTEST CHOICE ® Contact your Abbott Sales Representative today

 Open the catalog to page 9
iDesign - Advanced WaveScan Studio System-10

iDESIGN Advanced WaveScan Studio System ® Specifications For Site Preparation/ Installation Product Description The iDESIGN® Advanced WaveScan Studio (iDESIGN®) System measures the wavefront of the eye within a defined range using the Hartmann-Shack sensor. The sensor evaluates the deflection of rays emanating from a small beam of light projected onto the retina. The measurements determine regular (sphero-cylindrical) refractive errors and irregularities (aberrations) that cause reduced visual function. Laser vision-correction treatments can be calculated using measurements obtained from the...

 Open the catalog to page 10
iDesign - Advanced WaveScan Studio System-11

Recommended Room Requirements • Do not place the unit near windows or in a room that cannot be sufficiently darkened to allow the patient’s eyes to dilate naturally • Ambient operational temperature range: 60°F–80°F (15°C–27°C) • Humidity: Relative humidity no less than 35% and no greater than 65% (noncondensing) • Barometric pressure range: 11–16 psi (76–110 kPa) Storing Requirements Before Installation When storing the iDESIGN® System before installation, adhere to the following site requirements: • Storage temperature must be between 41 and 104°F (between 5 and 40°C) at a relative humidity...

 Open the catalog to page 11
iDesign - Advanced WaveScan Studio System-12

System Specifications Cont. • Motorized Table o Physical dimensions: (L, W, H) 52.5", 28.3", 31.9"-46.7" (min.-max.), (133.4 cm, 71.8 cm, 81.0-118.6 cm) o Weight: 149 lbs (68 kg) o Electrical ratings are 120 V, 50/60 Hz, 6 A o Vertical position is controlled by a rocker control switch (vertical height can range from 630 to 1,030 mm) o Tabletop supports iDESIGN® System and USB v2.0 keyboard o Shelves hold printer and isolation transformer • High-resolution color printer included • Medical-Grade Isolation Transformer o Input: 100/120/220/240 VAC at 50/60 Hz o Power: 750 VA o Complies with IEC 60601-1...

 Open the catalog to page 12
iDesign - Advanced WaveScan Studio System-13

System Specifications Cont. • Measurement spatial resolution 0.177 mm (approximately 1250 measurement points for a 7 mm pupil) • Integrated corneal topographer 37 x 37 spot measurement grid • Topographer grid extent (X and Y) ±4.1 mm for eye with 8 mm radius of curvature • Illumination ranging from 535 to 940 nm Hardware Components The iDESIGN® System includes, a built-in power supply, computer, and monitor. The computer central processing unit (CPU) is housed inside the iDESIGN® System. The USB port is located on the right-hand side of the computer case. The computer keyboard and built-in glidepad...