Product catalog summary
Company Overview
JRI Limited, established in 1970 by Mr. Ronald Furlong, specializes in orthopaedic research, development, and manufacturing. The company is renowned for introducing the first Hydroxyapatite Ceramic (H-A.C.) coated hip replacement, the Furlong® H-A.C., in 1985, which has shown exceptional clinical results.
Clinically Proven Results
The Furlong® H-A.C. hip replacement has demonstrated outstanding long-term success, with studies indicating 100% success rates over various durations. The H-A.C. coating facilitates biological fixation, and JRI has enhanced its application process using Vacuum Plasma Spray (VPS) since 1993 to improve coating quality and bond strength.
Furlong® H-A.C. Femoral Stem Design
The femoral stem design aims to eliminate subsidence and thigh pain, ensuring stable mechanical fixation and promoting bone growth. Its unique shape fits the femur's metaphysis, and the full-length H-A.C. coating ensures even force distribution.
Furlong® H-A.C. CSF plus Acetabular Cup System
This system enhances the Furlong® H-A.C. acetabular cup design with increased surface roughness for improved bone ingrowth and biological fixation. It offers ceramic bearing options for enhanced stability and range of motion.
Highly Cross Linked Polyethylene CLP75®
CLP75® liners are gamma irradiated for high crosslinking, reducing wear and oxidation. They feature a secure locking mechanism designed to minimize micro-movement and backside wear.
Patient and Surgeon Experiences
Patients report significant pain relief and improved mobility post-surgery. Surgeons note positive long-term outcomes with the Furlong® H-A.C. system, highlighting its suitability for younger patients and reduced revision rates.
Component Range and Specifications
The document details specifications for the Furlong® H-A.C. CSF plus acetabular cup component range, including various neck angles, offsets, and liner options to suit different patient anatomies.
JRI Services and Education
  • Research Funding: Support for orthopaedic research initiatives.
  • Nurse Training: Educational programs for nursing staff.
  • Factory Tours: Opportunities to visit manufacturing facilities.
  • Furlong Hip Courses: Specialized training on hip replacement procedures.
  • In-Service Support: Ongoing assistance for healthcare providers.
  • Consignment Stock Checks: Regular inventory checks for implants and instruments.
  • PACS Digital X-Ray Templates: Tools for digital imaging in orthopaedics.
Research and Data
  • Survivorship Studies: Multiple studies on hip implant longevity, including:
    • 38 cases in patients under 50 years old (Shah et al., 2009).
    • 331 consecutive cases (Shepperd et al., 2008).
    • 134 consecutive cases (Shetty et al., 2005).
    • 2212 cases presented at BOA, 2007 (Buchanan).
  • Hydroxyapatite Ceramic Coated Hip Implants: Long-term evaluations and clinical results presented at various conferences, demonstrating the effectiveness of these implants.
  • Data Sources: Contributions from institutions like the University of Leeds and CeramTecAG, as well as internal data.
Ownership
The Furlong Research Charitable Foundation owns JRI, funding independent orthopaedic research.
See more

Catalog excerpts

Furlong-2

Company Overview • JRI Limited, established in 1970 by Mr Ronald Furlong, FRCS • First H-A.C. coated hip replacement in the world – Furlong® H-A.C. 9th September 1985 • Market leading peer reviewed clinical results • Dedicated orthopaedic research, development and man

 Open the catalog to page 2
Furlong-3

Furlong® H-A.C. Femoral Stem Design Rationale 5-8 Furlong® H-A.C. CSF plus Acetabular Cup System 9 Highly Cross Linked Polyethylene CLP75® 10 CSF plus Ceramic Bearing Options 11 Reducing the risk of Impingement & Dislocation 12 Furlong® H-A.C. CSF plus Acetabular Cup component range 15-16 Primary Furlong® H-A.C. Dimension Chart 17 Primary Furlong® H-A.C. Stem Component Range 18

 Open the catalog to page 3
Furlong-4

Clinically Proven Aseptic loosening – a thing of the past! 1. Survivorship of 38 cases in under 50 year olds. N.N. Shah et al J Bone Joint Surg [Br] 2009; 91B:865-9 2. Survivorship of 331 consecutive cases. J.A.N Shepperd et al J Bone Joint Surg [Br] 2008; 90-B:27-30 3. Survivorship of 134 consecutive cases. A.A. Shetty et al J Bone Joint Surg [Br] 2005; 87-B:1050-4 4. Survivorship in 2,212 cases. J.M. Buchanan, Sunderland Royal Hospital Data presented at BOA 2007, Manchester, 26 - 28 September 2007 “These results compare favourably with the best long-term results of cemented or uncemented femoral...

 Open the catalog to page 4
Furlong-5

Not all H-A.C. coatings are the same The Furlong® Total Hip Replacement was the first in the world to utilise Hydroxyapatite Ceramic (H-A.C.) coating to promote biological fixation. Since its introduction in 1985 JRI have continued to develop and improve our H-A.C. coating and the way in which it is applied. One of the most important factors is whether the H-A.C. coating is applied in atmospheric (APS) or vacuum conditions (VPS). Supravit® is JRI’s VPS H-A.C coating. Fact: • All JRI implants have been VPS coated since 1993 • VPS removes oxygen and gas pockets • VPS produces a dense homogenous...

 Open the catalog to page 5
Furlong-6

Furlong® H-A.C. Femoral Stem – Design Rationale Elimination of Subsidence “Radiological assessment of the femoral components did not show any radiolucent lines and serial radiographs did not reveal any evidence of subsidence”1 “The collar on the femoral component prevents early subsidence of the prosthesis after implantation. Once bone has bonded to the prosthesis, its function becomes redundant”2 “There were no reactive lines at the bone-stem interface, no changes at the interface and no subsidence or osteolysis in any of the radiographs studied”3 “Initial stability of the stem is by interference...

 Open the catalog to page 6
Furlong-7

A cone shape prosthesis, as distinct from a wedge, when impacted firmly into the metaphysis creates “hoop stressing” which in general terms, is well tolerated by cortical trabecular bone. The deliberate accurate nature of the Furlong® instrumentation and surgical technique ensures precise primary mechanical fixation. The stem shape from the cone section upwards guarantees maximum proximal loading in Gruen zones 1 & 7 and 2 & 6. This allows Gruen zones 2&6 for confident post operative weight bearing and good early bone growth. Cross Section Furlong® H-A.C. Femoral stem histology Gruen zones Cross...

 Open the catalog to page 7
Furlong-8

Furlong® H-A.C. Femoral Stem – Design Rationale Elimination of thigh pain “Anterior thigh pain has been reported previously with the use of uncemented hip prosthesis. This was not the case in our study”2 “All patients were asked at each review about the occurrence of anterior thigh pain. None had experienced this at any stage”1 “Another significant feature of our study was the absence of thigh pain, in contrast with reports of other cementless femoral components without H-A.C.

 Open the catalog to page 8
Furlong-9

• Proximal body designed to fit the metaphysis of the femur – load transferred to and transmitted by the interface between prosthesis and cancellous bone – rectangular cross section of proximal body provides rotational stability under dynamic loading • Cone shaped geometric transition between proximal body and cylindrical distal stem – prevents subsidence and creates ‘hoop stressing’ of the cortical bone providing early stable mechanical fixation • Hydroxyapatite ceramic coating over the full length of the prosthesis – new bone grows primarily on and directly into the ceramic surface; fully coated...

 Open the catalog to page 9
Furlong-10

Furlong® H-A.C. CSF plus Acetabular Cup System Based on the clinically proven design of the Furlong® H-A.C. CSF Acetabular Cup the CSF plus system offers all the same benefits but with some key improvements.6,7,8 Dedicated Range of Acetabular Shell types • The application of 175μm Rough Titanium increases the surface area by 200%. This roughened surface significantly increases the coefficient of friction giving a superior scratch fit • Push-out tests have shown an Increased shear strength at the H-A.C. to bone interface as a function of surface roughness • The roughened surface increases the...

 Open the catalog to page 10
Furlong-11

Highly Cross Linked Polyethylene CLP75® During the manufacturing process radiation is used to “crosslink” the polyethylene chains resulting in a more durable material. • Gamma irradiated at 7.5Mrads producing 97.5% crosslinking which significantly reduces volumetric wear • Melt annealed to remove free radicals and restore mechanical properties, reducing oxidation • Calcium stearate free CLP75® and Ultra High Molecular Weight Polyethylene (UHMWPE) liners have a unique 5 degree taper which; • Provides secure non destructive locking mechanism • Secures seating of the liner • Ensures coupling is...

 Open the catalog to page 11
Furlong-12

CSF plus Ceramic Bearing Options All ceramics used in the Furlong® H-A.C. CSF plus Ceramic bearing Cup are Biolox® delta Ceramics; This system allows for the largest internal diameter bearing size to be used with the smallest outside diameter cup size, without any compromise to the strength of the implants. • 36mm Biolox® delta Ceramic Head in a • 40mm Biolox® delta Ceramic Head in a 54mm Acetabular Shell • An 18º internal taper provides excellent fixation of the liner in the shell Function Head Size (mm) 40 Maximise Suvivorship Optimise Function​ Increased Stability, Range of Motion5 Alumina...

 Open the catalog to page 12