FCV AB

FCV AB

FCV AB

Product catalog summary
Product Overview
The Feline Calicivirus Antibody (FCV-Ab) Test Kit is designed for in vitro veterinary diagnosis to detect FCV IgG antibodies in cats, indicating their immune status. It is particularly useful for evaluating immunity before and after vaccination and for early detection during FPV infection.

Packing Specifications
The kit contains 10 tests per box.

Detection Principle
The test uses fluorescence immunochromatography. It involves a T-line and C-line on a nitrate fiber membrane, with a fluorescent nanomaterial marker that binds specifically to FCV IgG antibodies. The fluorescence signal strength correlates with the antibody concentration.

Main Ingredients
1. FCV Ab test reagent card
2. Sample diluent
3. Tip
4. Instruction manual

Storage and Expiry
Store at room temperature with a shelf life of 36 months. Once opened, the test card must be used within 20 minutes.

Sample Requirements
Serum or plasma is required. Whole blood should be separated promptly. If not tested immediately, store serum/plasma at 2-8°C for up to 2 days.

Precautions
1. For veterinary use only, not for human use.
2. Use within the validity period.
3. Restore test card and diluent to room temperature before use.
4. Do not mix different batches or products.
5. Import the standard curve for the corresponding batch before testing.
6. Insert the test card into the instrument within 20 seconds after adding the sample.
7. Use in conjunction with other diagnostic methods.
8. Avoid hemolytic samples.

Operating Procedures
1. Turn on the instrument and enter test case information.
2. Restore sample and diluent to room temperature.
3. Mix 10 μL of serum/plasma with the sample diluent.
4. Add 3 drops (100 μL) of the mixture to the test card.
5. Insert the card into the slot within 20 seconds and select "Standard Test" or wait 10 minutes for "Quick Test".

Test Results
Low Titer: <10 U/mL
Medium Titer: 10-40 U/mL
High Titer: >40 U/mL
The detection range is 5-800 U/mL. Results <5 U/mL suggest immunization recommencement. Establish a reference range for each laboratory.

Recommendations
1. Use in conjunction with clinical practice for accurate diagnosis.
2. Low titer results suggest supplementary vaccinations.
3. Medium titer near low value may require revaccination.
4. High titer indicates ideal antibody levels.
5. False results are rare; confirm with other examinations if possible.
6. Contact the manufacturer for any issues.

Manufacturer Information
JZ Biotech Co. Ltd, Room 101, Building B2, No.13 Baolan Road, Xiuxin Community, Kengzi Street, Pingshan District, Shenzhen. Tel: 0755‐89218110. Website: www.jz-biotech.com.
See more

Catalog excerpts

FCV AB-1

Manual version:A-2502EN 1. FCV Ab test reagent card Feline Calicivirus Antibody(FCV-Ab)Test Kit Instruction (Rare Earth Nano-Fluorescence Immunochromatography) Please read the instructions carefully and follow the instructions before use. This product is only for in vitro veterinary diagnosis 【Preservation conditions and expiry date】 【Product name】Feline Calicivirus Antibody Test Kit Storage at room temperature (RT) with an effective period of 36 months; After the test card is opened, it must be used within 20 minutes. 【Applicable models】 (FCV Ab one step test) 【Packing specifications】 10 tests/ box 【Detection purpose】 Feline calicivirus (FCV) infection is a feline viral respiratory diseases. The 【Sample requirements】 general clinical manifestations are mainly upper respiratory symptoms, namely Serum/plasma: Whole blood needs to be separated as soon as possible. If the obtained depression, serous and mucous rhinorrhea, conjunctivitis, stomatitis, tracheitis, bronchitis, and biphasic fever. FCV infection is a frequently-occurring disease in serum/plasma cannot be tested in time, it can be stored at 2~8 °C for 2 days. 【Precautions】 cats, with high morbidity and low mortality. The content of FCV IgG antibody in a 1. This product is only for in vitro diagnosis by veterinarians, and it is strictly prohibited cat can reflect the immune status of the body. Clinical significance: 2. This product must be used within the validity period. 1) For the evaluation of the body before vaccination; 3. When used, the test card and sample diluent should be restored to room temperature. 2) Detection of the body's antibody titer after vaccination; 4. Different batches and products are not allowed to be mixed. 3) Early detection and diagnosis during the period of FPV infection. 5. Before the experiment, the standard curve of the corresponding batchs must be imported. 6. The test card shall be inserted into the instrument within 20s after the sample is added. 【Detection principle】 7. This product cannot be used as the basis for the final diagnosis of immunity, and should be combined with other diagnoses for comprehensive judgment. This product uses fluorescence immunochromatography to quantitatively detect the content of FPV IgG antibody in cat blood. The basic principle is as follows: 8. Try to avoid using hemolytic whole blood samples. There are T lines and C lines on the nitrate fiber membrane. The binding pad is 9. Each test card has one sample diluent, and it is strictly prohibited to reuse different sprayed with fluorescent nanomaterial marker that can specifically recognize FCV IgG. FCV IgG antibody in the sample first binds to the marker to form a complex, which then binds to the T-line. Under the excitation light, nano-material reflect 【Operating procedures】 fluorescence signal, and the strength of the signal is positively correlated with the

 Open the catalog to page 1
FCV AB-2

1. Turn on the instrumented enter the information of the test case. 2. The sample and sample diluent should be restored to room temperature; 3. Pipette draw 10 p L of serum/plasma into the sampl e diluent an d mix well; 4. Open the small cover (White) on the top of the dropper, inverted and squeeze the dropper to drop the mixed liquid (3 drops=100 pL) into the sample hole of the test card; 5. After adding the sample, insert card into the slot within 20s, and click ” Standard Test ”; Or after adding the sample, the test card should be inserted into the card slot after 10 minutes of timing response,...

 Open the catalog to page 2

All JZ Biotech catalogs and technical brochures

  1. RB02

    2  Pages

  2. JZ-FIAS7

    25  Pages

  3. JZVET-OT01

    2  Pages

  4. JZVET-WL01

    3  Pages

  5. JZVET-060C

    2  Pages

  6. JZVet-EX01

    2  Pages

  7. JZVet-CH02

    2  Pages

  8. JZVET-EX02

    2  Pages

  9. JZVET-CX01

    2  Pages

  10. JZVETDK

    1  Page

  11. SDMA

    2  Pages

  12. test kit

    2  Pages

  13. JZVet-EX

    1  Page

  14. JZVet-CH

    1  Page

  15. FHV AG

    2  Pages

  16. FPV AG

    2  Pages

  17. FCoV AB

    2  Pages

  18. FIV AB

    2  Pages

  19. FHV AB

    2  Pages

  20. FPV AB

    2  Pages

  21. FPV/FCV/FHV

    2  Pages

  22. FSAA

    2  Pages

  23. FPL

    2  Pages

  24. SDMA

    2  Pages

  25. JZ-FIA

    2  Pages

  26. PAG TEST

    1  Page

Archived catalogs

  1. JZVET-100B

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.