FSAA
1 /2Pages

FSAA

FSAA
1 /2Pages

Catalog excerpts

FSAA-1

Feline Serum Amyloid A (fSAA)Test Kit Instruction (Rare Earth Nano-Fluorescence Immunochromatography) 【Preservation conditions and expiry date】 Please read the instructions carefully and follow the instructions before use. Store at room temperature (RT), with a validity of 36 months. This product is only for in vitro veterinary diagnosis 【Product name】Feline Serum Amyloid A Test Kit ( fSAA one step test) 【Packing specifications】10 tests/ box 【Detection purpose】 Feline serum amyloid protein A (fSAA) is an acute phase reaction protein, can be used as a sensitive index of systemic inflammation and tissue damage markers. When the cat inflammation during the attack, the level of fSAA in blood can significantly increased rapidly. With the elimination of the inflammatory agent, the level of fSAA quickly drops back to normal. Although fSAA is a non-specific reactive protein, it plays a good guiding role in the diagnosis of subclinical inflammation, the detection of disease status and severity, and the observation of treatment effect and process, especially in the rational use of antibiotics. 【Detection principle】 This product uses fluorescence immunochromatography to quantitatively detect the content of fSAA in whole blood, serum/plasma. The basic principle is as follows: There are T lines and C lines on the nitrate fiber membrane. The T-line is coated with an antibody A that can specifically recognize the fSAA. On the binding pad is another antibody B, fluorescently labeled with a nanomaterial, which also binds to fSAA. The fSAA in the sample and antibody B form a combination and then chromatography. The complex reaches the T-line and binds to antibody A to form a sandwich structure. Under the excitation light, nano-material reflect fluorescence signal, and the strength of the signal is positively correlated with the concentration of fSAA in the sample. After the test card is opened,it must be used within 20 minutes. 【Applicable models】 Applicable to JZ001 for testing. 【Sample requirements】 Whole blood (or whole anticoagulant blood) : for immediate use; Serum/plasma: Whole blood needs to be centrifuged as soon as possible. If the obtained serum/plasma cannot be detected in time, it can be stored at 2~8 ° C for 2 days. 【Precautions】 1. This product is for in vitro diagnostic use only by veterinarians, and cross-use from human sources is strictly prohibited. 2. This product must be used within the validity period. 3. When using, the test card and sample dilution should be returned to room temperature .4. Cross-mixing of different batches and different products is strictly prohibited. 5. Before the experiment, the standard curve of the corresponding batchs must be imported. 6. The test card should be inserted into the instrument to start the test within 20s of dropping the sample. 7. This product cannot be used as the basis for the final diagnosis of the disease, and it needs to be comprehensively judged in combination with other diagnosis. 8. Try to avoid using hemolyzed whole blood samples. 9. Each test card corresponds to a sample dilution solution. Reuse of different samples is strictly prohibited. 【Main ingredients】 1. fSAA detection reagent card 【Operating procedures】

 Open the catalog to page 1
FSAA-2

1. Turn on the instrument, and enter the information of the test case. 2. The sample and sample diluent should be restored to room temperature; 3. Pipette draw 5 p L of whol e bloo d (2. 5 pL of serum/plasma ) to the sample diluent and mix it well. 4. Open the small cover (White) on the top of the dropper , inverted and squeeze the dropper to drop the mixed liquid (3 drops=100 pL) into the sample hole of the test card; 5. After adding the sample, insert card into the card slot within 20s, and click ” Standard Test ”. Or after adding the sample, the test card should be inserted into the slot after...

 Open the catalog to page 2

All JZ Biotech catalogs and technical brochures

  1. RB02

    2  Pages

  2. JZ-FIAS7

    25  Pages

  3. JZVET-OT01

    2  Pages

  4. JZVET-WL01

    3  Pages

  5. JZVET-060C

    2  Pages

  6. JZVet-EX01

    2  Pages

  7. JZVet-CH02

    2  Pages

  8. JZVET-EX02

    2  Pages

  9. JZVET-CX01

    2  Pages

  10. JZVETDK

    1  Page

  11. SDMA

    2  Pages

  12. test kit

    2  Pages

  13. JZVet-EX

    1  Page

  14. JZVet-CH

    1  Page

  15. FHV AG

    2  Pages

  16. FPV AG

    2  Pages

  17. FCoV AB

    2  Pages

  18. FIV AB

    2  Pages

  19. FHV AB

    2  Pages

  20. FCV AB

    2  Pages

  21. FPV AB

    2  Pages

  22. FPV/FCV/FHV

    2  Pages

  23. FPL

    2  Pages

  24. SDMA

    2  Pages

  25. JZ-FIA

    2  Pages

  26. PAG TEST

    1  Page

Archived catalogs

  1. JZVET-100B

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.