Symmetric Dimethylarginine(SDMA) Test Kit Instruction 【Storage conditions and validity period】 (Rare Earth Nano-Fluorescence Immunochromatography) Store at room temperature (RT), valid for 36 months; Please read the instructions carefully and follow the instructions before use. This product is for veterinary in vitro diagnostic use only. After opening the test card, it must be used within 20 minutes. 【Applicable models】 【Product Name】Symmetric Dimethylarginine(SDMA) Test Kit 【Packing specifications】 10 tests/box 【Detection Purpose】 Symmetric dimethylarginine (SDMA) is a by-product of kidney metabolism, so it can be used as a renal biomarker, and its level in the blood can indicate the level of kidney fun ction. Compared with creatinine testing, SDMA can indicate kidney function disorders such as acute kidney injury (AKI) and chronic kidney disease (CKD) earlier. Applicable to JZ001 for testing. 【Sample requirements】 Serum/plasma: Whole blood should be separated as soon as possible. If the obtained serum cannot be detected in time, it can be stored at 2~8 ℃ for 2 days. 【Precautions】 1. This product is for veterinary in vitro diagnostic use only, and cross-use by 【Detection Principle】 This product uses fluorescence immunochromatography to quantitatively detect the content of SDMA in the serum or plasma of dogs and cats. Basic principle: the nitrocellulose membrane is marked with T and C lines, the T line is coated with SDMA antigen A, and the binding pad is sprayed with antibody B labeled with fluorescent nanomaterials that can specifically recognize SDMA, and the SDMA in the sample first combines with the antibody B labeled with nanomaterials to form a complex, and then goes up to chromatography, the complex competes with the SDMA on the T line, and when the excitation light is irradiated, the nanomaterials emit a fluorescent signal, and the strength of the signal is negatively correlated with the antigen concentration in the sample. human sources is strictly prohibited. 2. This product must be used within the validity period. 3. When using, the test card and sample diluent should be restored to room temperature. 4. Different batches and different products are strictly prohibited to mix. 5. Before the experiment, the standard curve of the corresponding batchs must be imported. 6. The test card must be inserted into the instrument to start the test within 20s of adding the sample. 7. This product cannot be used as the basis for the final diagnosis of the disease, it needs to be combined with other diagnoses for comprehensive judgment. 8. Each test card corresponds to one sample diluent, and it is strictly prohibited to 【Main Ingredients】 reuse different samples. 1. SDMA test reagent card 9. Try to avoid the use of hemolysis of the whole blood sample. 2. Sample diluent 3. Tips 4. Instruction etc.
Open the catalog to page 11. Turn on the instrumented enter the information of the test case. 2. The sample and sample diluent should be restored to room temperature; 3. Pipette draw 100 pl of serum/plasma to the sample diluent and mix well; 4. Open the small cover (White) on the top of the dropper , inverted and squeeze the dropper to drop the mixed liquid (3 drops=100 pl) into the sample hole of the test card; 5. After adding the sample, insert card into the slot within 20s, and click "Standard Test" to wait for the Incubating and the test result; Or after adding the sample, the test card should be inserted into the...
Open the catalog to page 22 Pages
2 Pages
25 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
1 Page
2 Pages
2 Pages
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
88 Pages
4 Pages
2 Pages