1. Catalogs
  2. Kamiya Biomedical Company LLC
  3. Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025

Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025

Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025
1 / 27 PagesView full catalog

Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025

Product catalog summary
Overview
Kamiya Biomedical Company provides a variety of immunoassay reagents under the K-ASSAY® brand, suitable for use with chemistry analyzers. These reagents are primarily intended for research use in the U.S. and are not meant for diagnostic procedures.
Advantages
  • Compatible with most chemistry analyzers.
  • Offers a wide measuring range.
  • Reagents are liquid-stable, eliminating the need for dissolving, mixing, or dilution.
  • Most products maintain stability for 1 month after opening and have a shelf life of at least 1 year from manufacture.
  • No need for sample predilution.
Product Categories
  • Anemia: Ferritin, Transferrin, UIBC.
  • Cardiac Assessment: CRP, D-Dimer, Fibrinogen.
  • Coagulation: D-Dimer, Factor XIII, FDPs.
  • Diabetes/Stroke: Alpha-1 Microglobulin, Cystatin C, Hemoglobin A1c, Insulin.
  • Infectious Diseases: Beta-2 Microglobulin, Helicobacter pylori.
  • Inflammation: Anti-Streptolysin O, Complement C3 and C4, Rheumatoid Factor.
  • Kidney Function: Cystatin C, Microalbumin.
  • Lipid Assessment: Apolipoproteins, Lipoprotein(a).
  • Nutritional Assessment: Ferritin, Prealbumin, Transferrin.
  • Serum Proteins: Alpha-1 Acid Glycoprotein, Haptoglobin, Immunoglobulins.
Key Product Details
  • Alpha-1 Microglobulin: Uses immunoturbidimetric method, liquid format, with specific linearity ranges for urine and serum/plasma.
  • Anti-Streptolysin O: Immunoturbidimetric method, liquid format, with a linearity range of 20 - 1,000 IU/mL.
  • Apolipoprotein AI: Immunoturbidimetric method, liquid format, with a linearity range of 20 - 300 mg/dL.
  • Complement C3 and C4: Immunoturbidimetric method, liquid format, with specific linearity ranges for C3 and C4.
  • C-Reactive Protein: Immunoturbidimetric method, liquid format, with a linearity range of 1 - 250 mg/L.
Usage and Limitations
  • Products marked with an asterisk (*) are for research use only in the U.S. and not for diagnostic procedures.
  • High-sensitivity products and certain other reagents are not for use in the U.S.
Contact Information
For more information, visit www.k-assay.com or contact Kamiya Biomedical Company at 800-526-4925 or 206-575-8068.
Sections
  • Control Options: Urine FDP control options with lyophilized samples for research use only.
  • Ferritin: Immunoturbidimetric method for measuring ferritin in serum and plasma, including calibrators and controls.
  • Fibrinogen (Antigen): Immunoturbidimetric method for fibrinogen measurement in plasma, with necessary calibrators and controls.
  • H. pylori: Immunoturbidimetric method for H. pylori detection in serum and plasma, intended for research use only.
  • Haptoglobin: Immunoturbidimetric method for haptoglobin measurement in serum, including calibrators and controls.
  • Hemoglobin A1c: Immunoturbidimetric method for measuring Hemoglobin A1c in whole blood, with calibrators and controls.
  • Immunoglobulins (A, G, M): Methods for measuring IgA, IgG, and IgM in serum using immunoturbidimetric techniques, including calibrators and controls.
  • Insulin: Immunoturbidimetric method for insulin measurement in serum and plasma, with necessary calibrators and controls.
  • KL-6 (Ver.2): Immunoturbidimetric method for KL-6 measurement in serum and plasma, intended for research use only.
  • Lipoprotein(a): Immunoturbidimetric method for Lp(a) measurement in serum, including calibrators and controls.
  • Microalbumin: Immunoturbidimetric method for microalbumin measurement in urine, with calibrators and controls.
  • Prealbumin: Immunoturbidimetric method for prealbumin measurement in serum, including calibrators and controls.
  • Remnant Lipoprotein Cholesterol: Colorimetric method for RLP-C measurement in serum, intended for research use only.
  • Rheumatoid Factor (Ver.2): Immunoturbidimetric method for RF measurement in serum, with calibrators and controls.
  • Transferrin: Immunoturbidimetric method for transferrin measurement in serum, including calibrators and controls.
  • Unsaturated Iron Binding Capacity: Colorimetric method for UIBC measurement in serum, with calibrators.
  • Calibrators: Lists various calibrators for different assays, specifying their format and intended use.
  • Controls: Describes control options for various assays, including their format and analytes assayed.
Key Information
The document emphasizes the importance of using the correct calibrators and controls for each assay to ensure accurate results. It also highlights that certain products are for research use only and not for diagnostic procedures in the U.S.
See more

Catalog excerpts

Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025-1

Immunoassay Reagents f o r C h e m is t r y A n a l y z e r s CATALOG March 2025 KAMIYA BIOMEDICAL COMPANY

 Open the catalog to page 1
Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025-2

KAMIYA BIOMEDICAL COMPANY

 Open the catalog to page 2
Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025-3

K-ASSAY ®Immunoassay Reagents for Chemistry AnalyzersAdvantages Adaptable to most chemistry analyzers no dissolving, mixing, or dilution Wide measuring range Most products have 1-month stability after opening, > 1-year expiration from date of manufacture Anemia Cat. No.Diabetes/Stroke Cat. No.Kidney Function_Cat. No. Ferritin KAI-095 Cardiac Assessment CRP, High-Sensitive CRP, Wide Range D-Dimer D-Dimer, High-Sensitive Ferritin Fibrinogen (Antigen) Microalbumin Lipid Assessment_Cat. No. Infectious Diseases Cat. No. Beta-2 Microglobulin Helicobacter pylori Remnant Lipoprotein Cholesterol (RLP-C)...

 Open the catalog to page 3
Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025-4

Immunoassay Reagents for Chemistry Analyzers Alpha-1 Microglobulin Method: Immunoturbidimetric Format: Liquid Linearity: 0.2 - 34.0 mg/L (urine) 1.0 - 137 mg/L (serum/plasma) Sample: Urine or Serum/Plasma Anti-Streptolysin O Method: Format: Linearity: Sample: Description Alpha-1 Microglobulin R1: 1 x 50 mL buffer R2: 1 x 50 mL antibody Tests / Kit: 357 serum/plasma (H917) 500 urine (H917) Required Calibrator (Choose One): KAI-067C Urine Alpha-1 Microglobulin Calibrator 4 x 1 mL, liquid For 5 point calibration Immunoturbidimetric Liquid 20 - 1,000 IU/mL Serum Method: Format: Linearity: Sample:...

 Open the catalog to page 4
Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025-5

Immunoassay Reagents for Chemistry Analyzers Apolipoprotein AII Method: Format: Linearity: Sample: Immunoturbidimetric Liquid 10 - 100 mg/dL Serum Apolipoprotein B Method: Format: Linearity: Sample: For Research Use Only in the U.S. Not for use in diagnostic procedures in the U.S. Description Apo AII* R1: 4 x 18 mL buffer R2: 1 x 10 mL antibody Tests / Kit: 285 (H917) Immunoturbidimetric Liquid 25 - 250 mg/dL Serum Description Apo B R1: 3 x 20 mL buffer R2: 1 x 20 mL antibody Tests / Kit: 285 (H917) Apolipoprotein CII Method: Format: Linearity: Sample: Immunoturbidimetric Liquid 1 - 15 mg/dL...

 Open the catalog to page 5
Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025-6

Immunoassay Reagents for Chemistry Analyzers Apolipoprotein CIII Method: Format: Linearity: Sample: Immunoturbidimetric Liquid 3 - 30 mg/dL Serum For Research Use Only in the U.S. Not for use in diagnostic procedures in the U.S. Apolipoprotein E Method: Format: Linearity: Sample: Immunoturbidimetric Liquid 1 - 15 mg/dL Serum For Research Use Only in the U.S. Not for use in diagnostic procedures in the U.S. Method: Format: Linearity: Serum/Plasma: Urine: Immunoturbidimetric Liquid 0.2 - 80.0 mg/L 30 - 8,000 µg/L or 0.03 - 8.00 mg/L Sample: Serum, Plasma, Urine Description Apo CIII* R1: 3 x 20...

 Open the catalog to page 6
Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025-7

Immunoassay Reagents for Chemistry Analyzers Complement C3 Method: Format: Linearity: Sample: Immunoturbidimetric Liquid 30 - 350 mg/dL Serum Complement C4 Method: Format: Linearity: Sample: C-Reactive Protein Immunoturbidimetric Liquid 8 - 80 mg/dL Serum Method: Format: Linearity: Sample: Immunoturbidimetric Liquid 1 - 250 mg/L Serum For In Vitro Diagnostic Use. For In Vitro Diagnostic Use. Description Complement C3 R1: 4 x 20 mL buffer R2: 2 x 10 mL antibody Tests / Kit: 363 (H917) Description Complement C4 R1: 4 x 20 mL buffer R2: 2 x 10 mL antibody Tests / Kit: 363 (H917) Required Calibrator:...

 Open the catalog to page 7
Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025-8

Immunoassay Reagents for Chemistry Analyzers C-Reactive Protein, High-Sensitive Method: Format: Linearity: Sample: C-Reactive Protein, Wide Range Immunoturbidimetric Liquid 0.20 - 20.0 mg/L Serum, Plasma Method: Format: Linearity: Sample: Description hsCRP R1: 1 x 50 mL buffer R2: 1 x 10 mL antibody Tests / Kit: 200 (H917) Immunoturbidimetric Liquid 0.05 - 160 mg/L Serum, Plasma Description CRP (3) R1: 1 x 50 mL buffer R2: 1 x 50 mL antibody Tests / Kit: 333 (H917) Required Calibrator: CRP (3) Calibrator E 5 x 2 mL, liquid For 6 point calibration Immunoturbidimetric Liquid 0.06 - 8.00 mg/L Serum,...

 Open the catalog to page 8
Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025-9

Immunoassay Reagents for Chemistry Analyzers D-Dimer Method: Format: Linearity: Sample: Immunoturbidimetric Liquid 0.5 - 30 µg/mL Serum, Plasma D-Dimer, High-Sensitive Method: Immunoturbidimetric Format: Liquid Linearity: 0.03 - 8.00 µg/mL or 30 - 8,000 ng/mL Sample: Serum, Plasma Not For Use in the U.S. Description D-Dimer R1: 1 x 16 mL buffer R2: 1 x 8.5 mL antibody Tests / Kit: 114 (H917) Immunoturbidimetric Liquid 2.3 - 140 % Plasma Description D-Dimer, High-Sensitive** R1: 2 x 18 mL buffer R2: 1 x 7 mL antibody Tests / Kit: 175 (H917) Description Factor XIII R1: 2 x 9.5 mL buffer R2: 1 x...

 Open the catalog to page 9
Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025-10

Immunoassay Reagents for Chemistry Analyzers Plasma FDP Method: Format: Linearity: Sample: Immunoturbidimetric Liquid 2 - 80 µg/mL Plasma For Research Use Only in the U.S. Not for use in diagnostic procedures in the U.S. Description Plasma FDP* R1: 2 x 10.5 mL buffer R2: 1 x 6 mL antibody Tests / Kit: 120 (H917) Serum FDP Method: Format: Linearity: Sample: Immunoturbidimetric Liquid 0.2 - 80 µg/mL Serum Method: Format: Linearity: Sample: For Research Use Only in the U.S. Not for use in diagnostic procedures in the U.S. Description Serum FDP* R1: 2 x 12 mL buffer R2: 1 x 5 mL antibody Tests /...

 Open the catalog to page 10
Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025-11

Immunoassay Reagents for Chemistry Analyzers Ferritin Method: Format: Linearity: Sample: Immunoturbidimetric Liquid 2.0 - 1,000 ng/mL Serum, Plasma Fibrinogen (Antigen) Method: Format: Linearity: Sample: Description Ferritin R1: 1 x 18 mL buffer R2: 1 x 9 mL antibody Tests / Kit: 128 (H917) Immunoturbidimetric Liquid 100 - 900 mg/dL Plasma Description Fibrinogen R1: 2 x 20 mL buffer R2: 1 x 8 mL antibody Tests / Kit: 160 (H917) H. pylori Method: Format: Linearity: Sample: Immunoturbidimetric Liquid 3 - 100 U/mL Serum, Plasma For Research Use Only in the U.S. Not for use in diagnostic procedures...

 Open the catalog to page 11
Immunoassay Reagents for Chemistry Analyzers CATALOG March 2025-12

Hemoglobin A1c Immunoglobulin A Method: Immunoturbidimetric Format: Liquid Linearity: 20 - 220 mg/dL Sample: Serum Method: Immunoturbidimetric Format: Liquid Linearity: 2.0 - 16.0 % Sample: Whole Blood Method: Immunoturbidimetric Format: Liquid Linearity: 20 - 800 mg/dL Sample: Serum R1: 3 x 18 mL buffer R2: 2 x 7 mL antibody Tests / Kit: 254 (H917) Required Calibrator: KAI-016C Multi-Analyte Calibrator 6 x 1 mL, liquid For 6 point calibration Recommended Control: K49C-4M Liquid ITA Control R1: 1 x 30 mL buffer R2: 1 x 10 mL antibody Hemolysis Reagent: 1 x 125 mL Tests / Kit: 200 (H917) R1: 1...

 Open the catalog to page 12

All Kamiya Biomedical Company LLC catalogs and technical brochures

  1. Assay Flyer

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.