Kare Medical 2016
1 / 28Pages

Catalog excerpts

Kare Medical 2016 - 1

InhalationExpert InhalationExpert

Open the catalog to page 1
Kare Medical 2016 - 2

kmv5010 KMV 5010 delivers both pressure and volume ventilation, either invasively or non-invasively, to adult and pediatric patients weighting 5 kg or more (tidal volume>50 ml). Extreme portability and freedom of operation brought by a weight of 3.5 kg, 7-hour internal battery and 15-hour hotswap battery. Wide selection of both pressure and volume ventilation modes; including pressure modes CPAP ASB, PSV, aPCV, PCV and SIMVp, volume modes VCV and SIMVv. The KMV 5010 delivers complex and versatile ventilation therapy together with versa a user-friendly interface. It is easy to use use with...

Open the catalog to page 2
Kare Medical 2016 - 3

Volumetric Ventilation Key Features: • • • • • • • • • • Both pressure and volume ventilation, including SIMVv/SIMVp modes Modes: CPAP ASB, PSV, aPCV, PCV, VCV, SIMVv, SIMVp Portable: only 3.5 kg 7-hour internal battery & 15-hour external hotswap battery Easy to enter and lock clinical menu, a secure patient menu “Volume Targeting” available on PCV and PSV modes. On-screen real time graphics of pressure, flow and volume Up to 1 week of patient Trends could be examined from the device screen On-screen patient trends data of pressure, frequency and volume Alarms: High Volume, Low Volume, High...

Open the catalog to page 3
Kare Medical 2016 - 4

CPAP, PSV, Assisted PCV, PCV, ProSV, ProVT 3 - 35 cm H2O 50 - 2000 ml 4 - 50 bpm 1:0.3 - 1:4.0 1 - 5, Auto 10% - 90% 18.1 x 15.5 x 11.7 cm 1.260 kg < 30 dBA Optional SleepOne Heated Humidifer High pressure, Low pressure, High volume, Low volume, High frequency, High leak, Low battery, SD card out Pressure, Flow, Tidal Volume, Frequency 12 V, 8 A SD Card stores up to 365 nights of detailed therapy data. Data stored in the SD card can be processed via SleepOne TrackPro software Remote control and monitoring via realtime graphics is also possible with SleepOne Desktop software. With its...

Open the catalog to page 4
Kare Medical 2016 - 5

Invasive & Non Invasive pressure support ventilator r Suitable for the following diseases: he • • • • • Obstructive respiratory disorders such as COPD Restrictive respiratory disorders such as scoliosis, deformities of the thorax Neurological, muscular and neuromuscular disorders that affect respiratory Central respiratory regulation disorders Obstructive sleep apnea syndrome

Open the catalog to page 5
Kare Medical 2016 - 6

ProSV Cheyne-Stokes Respiration, Central Apnea, Obstructive Apnea All-in-One Solution Servo Ventilation + Auto Cpap + Respiratory Backup = SleepOne ProSVTM • • • • Auto Pressure Support Auto EPAP Auto Backup Rate Can also work as CPAP Mode Servo Ventilation (Min Pressure Support = 0) ProSV gives instant reaction to changes in patient effort. A Complex Device for increased Patient Complexity ! Technical Specifications Pressure Range Working Mode Ventilation Type Voltage Humidifier Data management 4-35 CmH2O ProSV Active Servo Ventilation, CPAP Leakage Ventilation 100 – 240 V AC SleepOne...

Open the catalog to page 6
Kare Medical 2016 - 7

Active Servo o Ventilation Device ProSV Active Patient Control on Breath-by-breath basis SleepOne ProSVTM is an active and also proactive device which responds to patients breath by breath changes. Patient who suffers from Cheyne-Stokes Ventilation, Central Apnea, Obstructive Apnea or Complex Apneas can benefit from the active/proactive algorithm of ProSVTM. Device monitors several parameters from the patients and adjust pressure and breath rate according to the change. Patients who don’t get enough from standard Bilevel therapy, or Auto-Bilevel algorithms can find the ProSVTM is a problem...

Open the catalog to page 7
Kare Medical 2016 - 8

ProVT Tidal Volume monitoring and targeting with ease SleepOne ProVTTM Pressure Support Ventilation Device Stabilizing Tidal Volume with ease SleepOne ProVTTM constantly monitors changes in the Tidal Volume of the patients. With Tidal Volume Targeting, It changes patient’s Pressure Support according to the Volume Target set. Pressure support ventilation for moving patient needs, easy as Bilevel therapy. SleepOne ProVTTM monitors the patients Tidal Volume changes, and reacts according to the set Tidal Volume. Result is a much more stable Tidal Volume for patient. Auto Backup Rate is also...

Open the catalog to page 8
Kare Medical 2016 - 9

Pressure Support with Volume Target Changing Pressure Support for changing needs Tidal Volume changes, sometimes according to sleep stages or body position or else. Whatever the reason for changing Tidal Volume, ProVTTM can cope with the situation and give the patient needed pressure to fulfill Target Volume at the right time. Technical Specifications Volume Target Tidal Volume ProVT changes pressure support in order to stabilize tidal volume. Pressure Range Working Mode Ventilation Type Voltage Humidifier 4-35 CmH2O ProVT, CPAP Leakage Ventilation 100 – 240 V AC SleepOne Heated Humidifier...

Open the catalog to page 9
Kare Medical 2016 - 10

SLEEPONE ^PAP L COMFORT EXRComfort Setting SleepOne CPAP creates a high comfort therapy for fixed pressure OSA patients. Small, lightweight and robust design makes it very portable together with universal power supply. Easy to adjust integrated heated humidifier, wide pressure range operation, Auto on and off functions fulfill all the needs for a successful therapy. Forget about costly accessories, you do not need to pay much for a decent therapy. No need to pay for getting your sleep data. Everything is included in this small, durable machine for a comfortable night sleep. A data...

Open the catalog to page 10
Kare Medical 2016 - 11

AUTO SleepOne AutoCPAP device provides a comfortable e therapy with the lowest possible therapy pressure. This s is done by the internal algorithm. Reaction to Snoring is s adjustable by the “Snore Sensitivity” Parameter. Small, lightweight and robust design makes it very portable e together with universal power supply. Easy to adjust t integrated heated humidifier, wide pressure range e s operation, auto on and off functions fulfill all the needs for a successful therapy. y Forget about costly accessories, you do not need to pay g much for a decent therapy. No need to pay for getting your...

Open the catalog to page 11
Kare Medical 2016 - 12

Affordable Spontaneous Bilevel Therapy, up to 25 cm H2OIPAP... Inspiration Trigger Expiration Trigger I:E Ratio IPAP Rounding EPAP Rounding Altitude Adjustment Dimensions (WxDxH) Weight Power Consumption Voltage Warranty Noise Level Report Software Auto-On/Auto Off Mask Off Data management • CPAP MODE 3 - 20 cm H2O (0.5 increments) • IPAP Range Bilevel Mode 6 - 25 cm H2O (0.5 increments) • EPAP Range Bilevel Mode 3 - 22 cm H2O (0.5 increments) 2 l/min - 20 l/min adjustable %10 - %90 of inspired flow 1:0.5 to 1:4.0 0 - 5 0 - 5 Automatic 18.1 x 15.5 x 11.7 cm 1.20 Kg. 65 Watt 100-230 V AC 2...

Open the catalog to page 12