1. Catalogs
  2. KARL STORZ
  3. UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery

UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery
1 /50Pages

UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery

UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery
1 /50Pages

Catalog excerpts

UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-1

UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery

 Open the catalog to page 1
UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-2

Endoscopes and accessories contained in this catalog have been designed in part with the cooperation of physicians and are manufactured by the KARL STORZ group. If subcontractors are hired to manufacture individual components, these are made according to proprietary KARL STORZ plans or drawings. Furthermore, these products are subject to strict quality and control guidelines of the KARL STORZ group. Both contractual and general legal provisions prohibit subcontractors from supplying components manufactured by order of KARL STORZ to competitors. Any assumptions that competitors’ endoscopes and...

 Open the catalog to page 2
UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-3

KARL STORZ ENDOSKOPE

 Open the catalog to page 3
UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-4

Over the past seven decades, we have been developing medical products that support users in the safe and gentle treatment of their patients. This was the goal of the company’s founder, Dr. med. h. c. Karl Storz, and has been the driving force behind KARL STORZ ever since its foundation in 1945. The endoscopes of the early 20th century did not offer physicians adequate visibility - telescopes and illumination did not meet their high medical standards and requirements. The company founder, Karl Storz, knew that these two challenges had to be mastered in order to unleash the immense potential of...

 Open the catalog to page 4
UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-5

Dr. h. c. mult. Sybill Storz, Chairofthe Supervisory Board “The development of minimally invasive surgery is inextricably linked with the name KARL STORZ. With foresight and a focus on quality, we have been developing products since 1945 that enable new treatment methods and make medical procedures even gentler and safer for patients.” “We want to make every product better and more perfect. Each product and each solution is like a child: You do everything in your power to help it reach its full potential.” “For us, shaping the future of endoscopy means to leverage proven solutions, to form new...

 Open the catalog to page 5
UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-6

DrillCut-X® 11-35 Shaver Handpieces Shaver Blades Sinus Burrs DrillCut-X® II Spine Handpiece Suction Burrs & Diamond Burrs for Spinal Endoscopy HighDrive™ & LightDrive High-Speed Drill Handpieces High-Speed Burrs Craniotome Attachments, High-Speed Craniotome Burrs

 Open the catalog to page 6
UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-7

INTRA Micro Motors INTRA Drill Handpieces 33 ENDOMAT® Select

 Open the catalog to page 7
UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-8

Motor System UNIDRIVE® Select STOTTC KARL STORZ ENDOSKDPE With the UNIDRIVE® Select, KARL STORZ is introducing a multidisciplinary motor system with a modular concept that allows configuration according to customer requirements thanks to software licenses. This technology opens up a wide range of customizable possibilities and also offers synergy effects in cross-speciality integration without disregarding economic efficiency. According to the motto “Power Anywhere”, the UNIDRIVE® Select motors and handpieces are driven with exactly the parameters required for the respective function and indication....

 Open the catalog to page 8
UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-9

UNIDRIVE® Select System components Software for use with UNIDRIVE® Select UM600 ENT UM601 NEURO UM602 SPINE UM603 Unit side Software for use with ENDOMAT® Select UP220 ENT/NEURO/ SPINE UP611 Patient side Shaver Blades, reusable Shaver Blades, for single use 41301FD Sinus Burrs, for single use

 Open the catalog to page 9
UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-10

UNIDRIVE® Select STOTC KARL STORZ ENDOSKDPE UM600 UNIDRIVE® Select, motor system with color display, touch screen control, two motor outputs, power supply 100-240 VAC, 50/60 Hz UP220 ENDOMAT® Select, suction or irrigation pump, incl. mains cord, power supply 100-240 VAC, 50/60 Hz, with integrated unit communication via KS HIVE

 Open the catalog to page 10
UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-12

UNIDRIVE® Select Mobile Stands STOTTC KARL STORZ ENDOSKDPE Subrack, COR mobile stand, low Top Cover Monitor Holder, COR mobile stand Special Equipment Shelf, COR mobile stand Stainless Steel Tube, COR mobile stand, length 400 mm Equipment Rail, COR mobile stand Footswitch Holder, forTwo-Pedal HF Footswitch UF902 Double Hook for Crossbar, height adjustable, for use with crossbar diameter 25 mm Multiple Socket Strip Set, COR mobile stand Isolation Transformer, 230 V, 600 VA Protective Housing Isolation Transformer Earth Leakage Monitor, 230 V, for isolation transformer Specal Mains Cord, length...

 Open the catalog to page 12
UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-13

DrillCut-X® II-35 Shaver Handpiece DrillCut-X® II-35 Shaver Handpiece, HQTWUGYKVJ70+&4+8'®5+++'060'741 70+&4+8'®5GNGEV

 Open the catalog to page 13
UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-14

KARL STORZ ENDOSKDPE DrillCut-X® II-35 Shaver HandpieceAccessories Cleaning Adaptor, LUER-Lock, for cleaning the inner and outer blades of DrillCut-X® accessories Included in delivery: 41200RA1 Cleaning Adaptor for Inner Blades 41200RA2 Cleaning Adaptor for Outer Blades 41250RA Cleaning Adaptor, LUER-Lock, for cleaning DrillCut-X® handpieces 39550A Wire Tray, provides safe storage of accessories for KARL STORZ paranasal sinus shaver systems during cleaning and sterilization For storage of: • Paransal sinus shaver handpiece • Connecting cable 031531-10 Tubing Set, for irrigation, UNIDRIVE®, sterile,...

 Open the catalog to page 14
UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-15

Shaver Blades SR3KZ KARL STORZ ENDOSKOPE Benefits of shaver blades: • Available as single-use or reusable products • Straight working inserts, 360° rotatable Cutting window: Cleaning Adaptor for reusable shaver blades Cleaning Adaptor, LUER-Lock, for cleaning the inner and outer blades of DrillCut-x® accessories 41200RA1 Cleaning Adaptor for Inner Blades 41200RA2 Cleaning Adaptor for Outer Blades

 Open the catalog to page 15
UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-16

Shaver Blades, reusable, straight for surgery of the paranasal sinuses and anterior skull base For use with 40712035 DrillCut-X® II-35 Handpiece Shaver Blades, straight, sterilizable Detailed view Shaver Blade, with integrated irrigation, length 12 cm serrated cutting edge, rectangular cutting window, diameter 4 mm, EQNQTEQFGDNWGTGF double serrated cutting edge, rectangular cutting window, diameter 4 mm, EQNQTEQFGDNWG[GNNQY concave cutting edge, oval cutting window, diameter 4 mm, EQNQTEQFGDNWGITGGP concave cutting edge, oblique cutting window, diameter 4 mm, EQNQTEQFGDNWGDNCEM straight cutting...

 Open the catalog to page 16
UNIDRIVE® Select for ENT, Neurosurgery and Spine Surgery-17

KARL STORZ ENDOSKOPE Shaver Blades, reusable, curved for surgery of the paranasal sinuses and anterior skull base For use with 40712035 DrillCut-X® II-35 Handpiece Shaver Blades, curved 35° / 40°, sterilizable

 Open the catalog to page 17

All KARL STORZ catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.