Analogue KAT (Z-Type) Keeler Applanation Tonometer Discover our full range at www.keelerglobal.com

 Open the catalog to page 1
KAT (Z-Type) Applanation Tonometer brochure-2

The trusted ‘gold standard’ for accurate IOP measurements and reliable glaucoma assessments We know how important it is to capture accurate measurements of intraocular pressure, for the best possible diagnosis outcomes for your patients. Our brand-new analogue Z-Type Keeler Applanation Tonometer (ZKAT) has been designed in collaboration with clinicians and handmade in the UK, adhering to the highest quality control standards, to equip you with the reliability and confidence you need. As a versatile measurement device for lower illumination slit lamps, ZKAT can be mounted on and used with slit...

 Open the catalog to page 2
KAT (Z-Type) Applanation Tonometer brochure-3

Discover our full range at www.keelerglobal.com

 Open the catalog to page 3
KAT (Z-Type) Applanation Tonometer brochure-4

• Precision machined components, to withstand the test of time • Carefully hand-assembled, adhering to stringent quality controls; pre, during and after assembly, to deliver reliable results year after year • Analogue readings you can trust, with no need for battery power • Calibration arm, for reassurance of accuracy with every use • The 'gold standard' in tonometry • Measurement arm safely stores away when not in use • With smooth-control readings between 0 and 80 mmHg • Effortlessly switch between re-usable or single-use prisms • Adjustable mount for the perfect view of your patient's mires...

 Open the catalog to page 4
KAT (Z-Type) Applanation Tonometer brochure-5

Accuracy with every use Daily checks, using the calibration arm provided, brings added reassurance around accuracy and reliability. The calibration arm simulates the pressures of 0, 20 and 60 mmHg being applied to the measurement arm, if the dial and measurement arm respond as expected, the ZKAT is accurately calibrated. Discover our full range at www.keelerglobal.com

 Open the catalog to page 5
KAT (Z-Type) Applanation Tonometer brochure-6

Veterinary Instruments

 Open the catalog to page 6
KAT (Z-Type) Applanation Tonometer brochure-7

Our analogue KAT (Z-Type) applanation tonometer is indicated for measuring intraocular pressure (IOP) to aid in the diagnosis of glaucoma. When used together with a slit lamp and tonometer prism, ZKAT operates according to the "Goldmann method", by measuring intraocular pressure from the force required to flatten (applanate) a constant area (3.06mm in diameter) of the cornea. As a measurement device for Z-style lower illumination slit lamps, the ZKAT can be correctly positioned onto the slit lamp using a compatible mounting bracket (also known as Z-Type Post). Following correct positioning, a...

 Open the catalog to page 7
KAT (Z-Type) Applanation Tonometer brochure-8

Visit keelerglobal.com for our full range including: Cryo surgery Slit lamps Contact details for your local Keeler distributor: Contact us Phone: +44 (0)1753 857 177 Email: [email protected] www.keelerglobal.com Keeler Europe Distribution, S.L. Colom, 453, nau D50 08223 Terrassa, Spain Medicel AG Dornierstrasse 11 CH-9423 Altenrhein, Switzerland Keeler Ltd. Clewer Hill Road, Windsor, SL4 4AA, UK GB KAT (Z-Type) - Keeler Applanation Tonometer