Catalog excerpts
D X-ray shielding Lower body x-ray shield (with patented collision tolerant pivotal arm) 312/DS-039/5 (complete with 10 mm thick 57 cm long integrated accessory rail) This lower body shield substantially reduces exposure to scatter radiation emanating from the table or patient’s body. The shield comprises a lightweight and durable structure, with enhanced friction maintaining middle link and pivotal arm supporting a flexible lead curtain. A unique patented mechanism enables the pivotal arm to move up when in collision with C-arm equipment. Semi-flexible top shields can be added to provide greater protection to the upper body, which can be quickly removed to ease patient transfer and access. Flexible x-ray protective curtain Kenex (Electro-Medical) Ltd Unit 17, R024 Greenway, Harlow Business Park, Harlow, Essex CM19 5QB, England T: +44 (0)1279 417241 F: +44 (0)1279 443749 E: kenex@kenex.co.uk www.kenex.co.uk > The shield easily mounts to either side of the table allowing the pivotal arm to always face the head end. > A 72 cm wide attachment bracket slides onto a 25mm high tableside accessory rail (maximum 11 mm thick). The securing handle position allows the shield to overhang the rail end and be repositioned further along the table if required. > The heavy duty friction maintaining middle link ensures accurate joint friction preventing unwanted curtain movement even when the table is tilted in any direction. > Equipment controls can be mounted on the large integrated rail and grouped with others close by on the adjacent tableside rail. > The curtains form a large (137 cm wide x 70 cm high) safe zone of occupancy for the Radiologist (or Cardiologist) and another person standing nearby. > The curtains form around an under table x-ray tube without impeding movement. > The curtain's inner 0.5 mm lead equivalent layer is bonded to its outer covering. As the protective layer is not suspended separately in a cover (bag), it cannot tear or fall away inside unnoticed. > The pivotal arm and middle link can swivel outwards from the table side to form a 48 cm or 65 cm wing, or inwards to conform to the shape of the table
Open the catalog to page 1X-ray shielding Weights and dimensions are subject to manufacturing tolerance 312/DS-039/5 comprising:-1 x Main element with equipment rail (312/DS/039/5-1) 1 x 48 cm pivoting element (312/DS/039/2-2)
Open the catalog to page 2All Kenex Electro-Medical catalogs and technical brochures
-
312_W_LBT
2 Pages
-
Lower body shields brochure
24 Pages
-
Ceiling track 3001/TC
2 Pages
-
Head end table shield 313/A2
2 Pages
-
Head end table shield 313/A3
1 Pages
-
Mobile apron rail 103
1 Pages
-
LytaType kilt (skirt) 919
2 Pages
-
LytaType jacket (vest) 915
2 Pages
-
LytaType half back apron 910
2 Pages
-
LytaType Demi apron 921
1 Pages
-
Mobile rack 1342/A2
2 Pages
-
LED 150F
2 Pages
-
LED 130F
2 Pages
-
Ceiling mounting plate 300/P
1 Pages