Lower body x-ray shield 312/E-016
2Pages

{{requestButtons}}

Catalog excerpts

Lower body x-ray shield 312/E-016 - 1

X-ray shielding 100 cm wide lower body x-ray shield 312/E-016 supplied with: -1 off 25 mm x 10 mm x 35 cm long integrated accessory rail (fitted) 1 off 28.6 mm x 9.5 mm x 35 cm long integrated accessory rail 312/E-016/8 supplied with: -1 off 25 mm x 7.7 mm x 35 cm long integrated accessory rail (fitted) This lower body shield substantially reduces exposure to scatter radiation emanating from the table or patient’s body. The shield comprises a lightweight and durable structure, with enhanced friction maintaining middle link and pivotal arm supporting a flexible lead curtain. An optional semi-flexible top shield (27 cm wide - short) provides additional protection to the upper body. Flexible x-ray protective curtain > The shield easily mounts to either side of the table allowing the pivotal arm to always face the head end. > A 51 cm wide attachment bracket slides onto a 25 mm or 28.6 mm high tableside rail (maximum 11 mm thick). The securing handle position allows the shield to overhang the rail end and be repositioned further along the table if required. > Equipment controls can be mounted on the large integrated rail and grouped with others close by on the adjacent tableside rail. > The semi-flexible 57 cm wide top can be quickly and easily removed as required to aid patient access. > The curtain forms a large (100 cm wide x 70 cm high) safe zone of occupancy for the Radiologist (or Cardiologist) and another person standing nearby. > The curtain forms around an under table x-ray tube without impeding movement. > The curtains inner 0.5mm lead equivalent layer is bonded to its outer covering. As the protective layer is not suspended separately in a cover (bag), it cannot tear or fall away inside unnoticed. > The pivotal arm and middle link can swivel outwards from the table side to form a 49 cm wing. Kenex (Electro-Medical) Ltd Unit 17, R024 Greenway, Harlow Business Park, Harlow, Essex CM19 5QB, England T: +44 (0)1279 417241 F: +44 (0)1279 443749 E: kenex@kenex.co.uk www.kenex.co.uk 312/E-016 & 016/8 iss8 (2023/10/16)

Open the catalog to page 1
Lower body x-ray shield 312/E-016 - 2

D X-ray shielding Optional top shields and storage > An optional 27 cm wide detachable top (as shown) overlaps the 57 cm wide top to provide additional protection to the upper body. > The 57 cm wide top attaches to the pivotal arm. The accompanying optional 27 cm wide top (312/DS/3.41) fits onto the attachment bracket. > The semi-flexible tops stand above the table and can be moved towards the patient as required. > Each can be quickly removed to aid patient access. > The x-ray attenuating material used in all tops has a lead equivalent of 0.5 mm. > Wall mounted or mobile storage racks:...

Open the catalog to page 2

All Kenex Electro-Medical catalogs and technical brochures

  1. LED 150F

    2 Pages

  2. LED 130F

    2 Pages