KX-01

KX-01

KX-01

Product catalog summary
Overview: The Kettex EVision EndoscopyCam KX-01 is a diagnostic camera designed for medical purposes, offering high-resolution imaging at a competitive cost. It is not intended for surgical operations.
Specifications: The camera features a native resolution of up to 2048×1536 pixels using a Sony 1/1.8” global shutter chip, producing 25-90 frames per second. It connects to a PC via a USB3 connector and lacks a processor unit.
Usage and Compatibility: The KX-01 is designed for use with a PC, a touchscreen, and a foot switch, allowing hands-free operation. It is compatible with EVision software, which provides functionalities such as image/video saving, vessel highlighting, image sharpening, noise reduction, fibroscopic grid correction, and HDR imaging.
Compliance and Risk Class: Both the camera and software are classified as risk class I and comply with MDR (EU 745/2017) regulations.
System Components: A complete endoscopic system includes the KX-01 Camera, EVision Software, a medical PC setup, a medical switch, zoom scale, stand/wall mount, camera holder, endoscope (stiff/flexible), and a light source.
Advanced Features:
  • Fibroscopic Grid Correction: Removes grid patterns while preserving image data in real-time at 25 fps.
  • Vessels Highlighting (ExView): Uses an RGB filter to highlight blood vessels, aiding in distinguishing normal structures from those affected by precancerous conditions or tumors.
  • Noise Reduction: Real-time algorithm reduces noise while maintaining image details, especially useful in low-light conditions.
  • Side-by-Side Comparison: Allows easy navigation and comparison of up to four images/videos simultaneously.
  • HDR Imaging: Compensates for lighting discrepancies by fusing images with different exposures in real-time.
Target Users: The camera is primarily used by ORL specialists, urologists, gynecologists, and veterinarians. Its global shutter capability makes it suitable for functional vocal cord examinations.
Contact Information: For inquiries, contact Dr. Filip Krolupper, Ph.D., at [email protected] or visit www.kettex.eu.
References: The document lists numerous medical professionals and institutions across various countries that utilize the KX-01 camera.
See more

Catalog excerpts

KX-01-1

Kettex EVision EndoscopyCam KX-01

 Open the catalog to page 1
KX-01-2

Our KX-01 camera provides an excellent image at an insurmountable cost. The camera has a native resolution of up to 2048×1536 pixels, using Sony 1/1.8” global shutter chip. The camera produces between 25-90 fps. The camera has a USB3 connector to connect to the computer and has no processor unit. The camera is designed to be used in conjunction with a PC for medical purposes with a touch screen and a foot switch used to operate the camera - the camera does not contain any buttons. In this way, the doctor has both hands free for examination. It works with our EVision software, which allows for...

 Open the catalog to page 2
KX-01-3

Fibroscopic grid correction – our software is able to remove fibroscopic grid and preserve all the data at the image. We do it on live stream at 25 fps, so the image remains fluent. The most interesting camera functions in more detail follow: Vessels highlighting (ExView) – automatically selected RGB filter highlights blood-vessels in the tissue. Thus you can distinguish the common blood-vessels structure from the one which was created by precancerosis or tumor. Noise Reduction – when the doctor observes distant places or if he/she has not very powerfull light source the image contains some additional...

 Open the catalog to page 3
KX-01-4

Side-by-side Comparison – our video player allows easy drag&drop navigation in the video, frame-by-frame going through the video by a wheel, capturing images from a video by a single click and comparison up to 4 images/ videos side by side. HDR Imaging – tissue near the endoscope can be overilluminated while the distant part can be under-illuminated. This is because the amount of light decrease rapidly with the distance from endoscope tip. We can compensate it by capturing two images with different exposure times and fusing it into the single picture. We are able to do it in realtime on live...

 Open the catalog to page 4
KX-01-5

References: ENT Dep. Hospital Motol prim. MUDr. P. Jablonický, MUDr. J. Sýba (CZ) ENT Medical Office Hradec Králové ProSluch s.r.o (CZ) ENT Dep. Hospital Homolka prim. MUDr. P. Jirák (CZ) ENT Medical Office Opava MUDr. Karel Hanuška (CZ) ENT Medical Office Regensburg MUDr. Hromada (DE) ENT Medical Office Senica MUDr. Vrancová (SK) Audio-Fon centr. doc. MUDr. M. Lejska, CSc., MUDr. R. Havlík, Ph.D (CZ) ENT Medical Office Hlohovec MUDr. Breza (SK) ENT Dep. János Kórház Hospital, Budapest prof. Dr. A. Hirschberg (HU) ENT Medical Office Nové Mesto nad Váhom MUDr. Feriancová (SK) ENT Dep. Szpital...

 Open the catalog to page 5

All Kettex Development catalogs and technical brochures

  1. KX-01-OR

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.