1. Catalogs
  2. Kinetec
  3. Kinetec Prima Advance with Washable Pads

Kinetec Prima Advance with Washable Pads

Kinetec Prima Advance with Washable Pads
1 / 38 PagesView full catalog

Kinetec Prima Advance with Washable Pads

Product catalog summary
Introduction
The KINETEC Prima Advance is a passive mobilization device for the knee, designed to assist in rehabilitation by promoting joint movement. It is crucial to read the user manual before use, as technical modifications may occur.
Indications and Clinical Benefits
The device is suitable for knee and hip surgeries, fractures, and other orthopedic procedures. It aids in breaking the cycle of trauma and immobility, preventing joint stiffness, speeding recovery, and reducing hospitalization time.
Contraindications
Not recommended for patients with rheumatoid arthritis in the inflammatory phase, gout attacks, infected wounds, certain bone conditions, or those outside the height range of 1.4m to 2m.
Device Description
The device allows knee flexion-extension from -5° to 115° and includes components like leg and thigh cradles, an articulated sole, and a control panel.
Electrical Connection and Safety
Operates on 100-240 V~ 50/60 Hz and requires a grounded outlet. Safety checks include ensuring undamaged power cords and compliance with Directive 89/336/CEE and IEC 601.1 standards.
Operation
Features start/stop/reverse functions with adjustable flexion and extension limits and speed settings from 40° to 145° per minute.
Hygienic Cover Use
Each patient should use a separate hygienic cover, which can be disinfected and reused.
Patient Installation
Adjust the device for patient comfort, measure thigh length, and align the hip and knee articulation axes with the device.
Maintenance and Cleaning
Maintenance is required after 2,000 hours of use, indicated by a flashing LED. Cleaning involves using disinfectant solutions on surfaces and covers.
Disposal and Recycling
Components should be separated and recycled appropriately, with specific methods for electronic and metal parts.
Troubleshooting
Common issues include non-functioning LEDs or device malfunctions, with solutions involving power supply checks and fuse replacements.
Technical Specifications
The device weighs 11.8 kg, with dimensions of 94cm x 33cm x 33cm, suitable for patients 1.5m to 1.95m tall, and operates in temperatures from +10°C to +40°C.
Warranty and Accessories
A two-year warranty is provided against manufacturing defects. Accessories include a trolley, mattress, and straps.
Electromagnetic Compatibility
Designed for specified electromagnetic environments, ensuring minimal interference with other electronic devices.
See more

Catalog excerpts

Kinetec Prima Advance with Washable Pads-3

MANUEL D’UTILISATION Indications Avantages Cliniques • Arthroplasties des articulations genou et hanche. • Fractures fémorales ou tibiales ostéosynthèsées. • Fractures patellaires. • Arthrolyses et chirurgies palliatives (lésions cartilagineuses, ablation d’ostéomes...). • Ostéotomies du bassin ou du fémur. • Ligamentoplasties (LCI, LCE, LLI, LLE). • Libération de l’appareil extenseur du genou (opération de Judet). • Synovectomies, Méniscectomies, Patellectomies, Arthroscopies. • Efficace pour briser le cercle vicieux : traumatisme immobilité épanchement atrophie. • Prévention de la raideur articulaire...

 Open the catalog to page 3
Kinetec Prima Advance with Washable Pads-4

Actionner l'interrupteur (2). La LED jaune (3) du tableau de commande s’allume. Fonction MARCHE / ARRET / INVERSION L’attelle KINETEC Prima Advance est dotée, comme toutes les attelles KINETEC, de la fonction MARCHE/ARRET/INVERSION. Au premier appui sur le bouton de la poignée de commande le mouvement s’arrête. Au second appui, le mouvement repart en sens inverse. IMPORTANT : pour un maximum de sécurité, la poignée de commande doit toujours être confiée au patient. Réglage des limites de FLEXION et d’EXTENSION Sélectionner les angles de flexion et d’extension à l’aide des boutons (4) pour la...

 Open the catalog to page 4
Kinetec Prima Advance with Washable Pads-5

8 • MAINTENANCE Apres 2.000 heures de fonctionnement, I'attelle KINETEC Prima Advance necessite quelques operations de graissage et d'entretien (graissage des articulations, de la butee a aiguilles et de la vis a billes si necessaire) realise par un technicien agree. Cette operation d'entretien est signalee par la LED qui clignote 5 fois a la mise sous-tension. Malgre cet avertissement, vous pouvez continuer a utiliser votre attelle KINETEC en appuyant sur la touche de la poignee de commande mais vous devez contacter votre specialiste KINETEC le plus proche pour realiser cette operation d'entretien. 9...

 Open the catalog to page 5
Kinetec Prima Advance with Washable Pads-6

14 • CONDITIONS DE GARANTIE La garantie KINETEC est strictement limitee au remplacement gratuit ou a la reparation en usine de la piece ou des pieces reconnues defectueuses. KINETEC garantit ses appareils de mobilisation passive articulaire 2 ans contre tous vices de fabrication, a partir de la date d'achat par le consommateur. KINETEC est le seul habilite a juger de l'application de la garantie sur ses appareils. La garantie ne peut intervenir si l'appareil a fait l'objet d'un usage anormal ou a ete utilise dans des conditions d'emploi autres que celles contenues dans notre manuel d'utilisation. La...

 Open the catalog to page 6
Kinetec Prima Advance with Washable Pads-7

INDICATIONS • Knee replacement surgery. • Fractures (patellar, tibia plateau, femoral,...). • Arthrolysis. • Hip surgery, including hip replacement, hip pinning, osteotomy,...). • Ligament repairs. • Arthroscopic surgery (menisectomies, patellectomies,...) • Burns, joints sepsis,... CLINICAL BENEFITS • Breaks the cycle of trauma, inflammation and the loss of range of motion. • Prevents joint stiffness. • Speeds the recovery of post-operative range of motion. • Maintains the quality of the joint surface. • Reduces pain and oedema. • Promotes joint cartilage healing. • Reduces hospitalization time •...

 Open the catalog to page 7
Kinetec Prima Advance with Washable Pads-8

Turn on the power switch (2). The yellow light (3) on the control panel is on. START / STOP / REVERSE function The KINETEC Prima Advance is fitted with a START/STOP/REVERSE function. First, press the hand control switch; the machine stops. Press the hand control switch again; the mobilization reverses. IMPORTANT: for maximum safety, the hand control should always be given to the patient. Adjusting the FLEXION and EXTENSION limits Select the extension and flexion angles via button (4) for flexion and button (5) for extension. Modification of the extension or flexion limit can be done while the...

 Open the catalog to page 8
Kinetec Prima Advance with Washable Pads-9

8 • MAINTENANCE After 2,000 hours of operation, KINETEC Prima Advance requires a few lubrication and maintenance operations (lubrication of the joints, pointer stops and ball screws). When the machine is switched on the yellow light blinks 5 times to indicate that the service interval has been reached. Despite that warning, you can continue to use your KINETEC Prima Advance by pressing START, but you should contact your nearest KINETEC technician to have the maintenance operations conducted as soon as possible. 9 • CLEANING Before conducting any cleaning operation, SWITCH the unit OFF and disconnect...

 Open the catalog to page 9
Kinetec Prima Advance with Washable Pads-10

14 • WARRANTY The KINETEC warranty is strictly limited to the replacement free of charge or repair in the plant of the component or components found to be defective. KINETEC guarantees its joint passive mobilization systems for 2 years against all defects of manufacture from the date of purchase by the consumer. KINETEC is the only organization able to assess the application of the warranty to its systems. The warranty will be considered null and void if the device has been used abnormally or under conditions of use other than those indicated in the user's manual. The warranty will also be considered...

 Open the catalog to page 10
Kinetec Prima Advance with Washable Pads-11

BEDIENUNGSANLEITUNG Anwendungsgebiete Klinische Vorteile • Knie- und Hüftgelenk-Totalendoprothese. • Durch Osteosynthese versorgte Frakturen von Tibia oder Femur. • Patellafrakturen. • Gelenkmobilisierung und palliative Eingriffe (Knorpelschäden, Entfernung von Osteomen, etc.). • Osteotomien von Femur oder Becken. • Bandplastik (vorderes oder hinteres Kreuzband, inneres oder äußeres Seitenband). • Mobilisation des Streckapparats des Kniegelenks (OP n. Judet). • Synovektomie, Meniscektomie, Patellektomie, Arthroskopie. • Wirksame Unterbrechung des Teufelskreises Trauma --> Immobilisierung -->...

 Open the catalog to page 11
Kinetec Prima Advance with Washable Pads-12

Den Schalter (2) betätigen. Die gelbe LED (3) im Bedienfeld leuchtet auf. Funktion START / STOP / BEWEGUNGSUMKEHR Die Schiene KINETEC Prima Advance ist wie alle KINETEC-Schienen mit der Funktion START/STOP/BEWEGUNGSUMKEHR versehen. Beim ersten Drücken des Bedienschalters hält die Bewegung an. Beim zweiten Drücken nimmt die Bewegung in entgegengesetzter Richtung wieder auf. WICHTIG: Damit eine maximale Sicherheit gegeben ist, muss der Bedienschalter immer dem Patienten anvertraut werden. Einstellung der Grenzen für FLEXION und EXTENSION Wählen Sie die Flexions- und Extensions-Winkel mit Hilfe...