Nurse Call Systems Air Dotmatrix Nurse Panel • Displays 4 calls simultaneously • Other calls are held in queue and shown on screen in order of priority • Adjustable 5 digits can show room and bed number • LED indicator shows call status Red – Normal Call Green – Nurse Presence Blue – Emergency / WC Call • 433 MHz wireless frequency • Can output active calls and logs to an Air Basic Reporter Software installed PC via serial port • Programmable manually using on-device buttons • Supports up to 64 Air Call Units • Audio alerts in different tones according to call type • Mute mode Technical Specification ZKRUNCWRNCSPC10 Weight Operating Voltage Operating Temperature Wireless Coverage Wireless Frequency 433 Mhz, Encrypted Communication Protocol
Open the catalog to page 1Nurse Call Systems Air Bedside Call Unit The Air Bedside Call Unit is used in patient rooms. There are call and cancel buttons on the unit. In an emergency, a patient uses the call button to make an emergency call which appears as an alert on the Nurse Panel. Typical locations for this unit are on the walls of patient rooms and living areas. • Air Patient Handsets work through connection to this unit • Can be flush mounted and has an ergonomic design • Battery lasts up to 5000 calls • Made of high quality PC-ABS-FR Raw Materials Technical Specification ZKRUNCWRWL10100 Weight Mounting Dimensions...
Open the catalog to page 2Nurse Call Systems Air Patient Handset The Air Patient Handset allows the patient’s condition to be reported quickly to hospital staff in an emergency situation. The device works through connection to the Air Bedside Call Unit. Easy-to-understand labels indicate the functions of the buttons. Technical Specification ZKRUNCWRHS10100 Weight Operating Temperature / Humidity 1.5 Meter Spiral Cable Reassurance Light
Open the catalog to page 3Nurse Call Systems Air Pull-Cord Call Unit The Air Pull-cord Call Unit is used in patient bathrooms or similar areas. There is a cancel button and an emergency call pull-cord on the unit. In an emergency, the patient makes an emergency call by pulling the cord. This appears as a WC Emergency Call on the Nurse Panel. The system gives priority to WC Emergency calls and they appear before nurse calls. Technical Specification ZKRUNCWRWC10100 Weight Rope Capacity Operating Temperature / Humidity Power Supply Battery Life Wireless Range Wireless Frequency 433 Mhz Encrypted Communication Protocol
Open the catalog to page 4Nurse Call Systems Air Over Door Light The Air Over Door Light is located above the patient room door in the corridor. Its half-sphere shape makes it easily noticeable from any angle of view. It can indicate the call status of the room with 3 main colors, red, green, and blue. It has very low energy consumption with environment-friendly LEDs. It is typically surface mounted but can also be flush mounted if preferred. • Maintenance/technical support free • Plug and play architecture • 3 different colors (red, green, blue) • Very low energy consumption • Environment friendly LEDs Technical Specification...
Open the catalog to page 5Nurse Call Systems Signal Repeater Expands signal coverage between Air Call Units and Air Nurse Panels when necessary. There is no restriction on the number of repeaters that can be used. Requires external 5V DC Power Supply. Technical Specification ZKRHNWRREP10010 Weight Operating Temperature / Humidity Power Supply Operating Voltage Metallic grey Wireless Frequency 433 Mhz, Encrypted Communication Protocol
Open the catalog to page 6Nurse Call Systems EC-232 The EC-232 is a plug-and-play ethernet-serial converter that you can connect to your devices or computer through RS232. You can quickly and easily relay data from an ethernet line to RS232 or from RS232 to ethernet line. This converter is designed to be easy-to-use in any layout. Entering and configuring IP addresses is enough to use the EC-232. You can connect your devices securely to the ethernet network and, and reach them through LAN, WAN, and Internet. EC-232 may work as TCP (Server/Client) or UDP (Server/Client). Technical Specification ZKRTNWEC232C100 Weight Stationary...
Open the catalog to page 7Nurse Call Systems Technical Specification ZKRUNCIPPOSPG10 Protocol Frequency Range Receiver Type Baud Rate Paging Sensitivity Channel Spacing Frequency Deviation Frequency Stability Image Rejection Spurious Rejection Alert Tone Loudness 16 characters / line, 22 characters max Memory Capacity Battery Type Low Battery Alert Level Operating Temperature
Open the catalog to page 8Nurse Call Systems Pager Transmitter Technical Specification ZKRUNCIPPGWR100 Protocol Operating Temperature / Humidity Frequency Range Channel Spacing Power Consumption Receiver Sensitivity Harmonic Radiation Frequency Stability Antenna Connection
Open the catalog to page 9Nurse Call Systems Text Panel The Text Panel is a scrolling 15-character dot matrix screen. It works with TCP-IP on the network, displays the calls as text, and gives audio alerts. Based on preference it can be set to display only specific types of calls. It works with 110-240 V. Mounting Bracket Technical Specification ZKRUNCIPTXTPNL18 Weight Operating Temperature / Humidity Power Supply Power Consumption Operating Voltage