Overview: The document provides technical specifications for various components of a Nurse Call System, designed to facilitate communication in healthcare settings. Key components include the Air Dotmatrix Nurse Panel, Air Bedside Call Unit, Air Patient Handset, Air Pull-Cord Call Unit, Air Over Door Light, Signal Repeater, EC-232 Ethernet-Serial Converter, Pager, Pager Transmitter, and Text Panel.
Air Dotmatrix Nurse Panel: Displays up to four calls simultaneously with additional calls queued by priority. Features include adjustable display for room and bed numbers, LED indicators for call status, wireless communication at 433 MHz, and compatibility with Air Basic Reporter Software. Supports up to 64 Air Call Units and provides audio alerts.
Air Bedside Call Unit: Used in patient rooms with call and cancel buttons. Connects to Air Patient Handsets and features a battery life of up to 5000 calls. Made from PC-ABS-FR material and supports flush mounting.
Air Patient Handset: Allows quick reporting of patient conditions. Connects to the Air Bedside Call Unit and features easy-to-understand labels and a reassurance light.
Air Pull-Cord Call Unit: Installed in bathrooms, features an emergency call pull-cord and cancel button. Prioritizes WC Emergency calls on the Nurse Panel.
Air Over Door Light: Indicates room call status with red, green, and blue LEDs. Features low energy consumption and can be surface or flush mounted.
Signal Repeater: Expands signal coverage between Air Call Units and Nurse Panels. Requires a 5V DC power supply and supports unlimited repeaters.
EC-232 Ethernet-Serial Converter: Facilitates data relay between ethernet and RS232 connections. Supports TCP and UDP protocols and features plug-and-play architecture.
Pager and Pager Transmitter: Operate on POCSAG protocol with a frequency range of 433-434 MHz. The pager features a 16-character display and supports up to 3000 characters in memory.
Text Panel: Displays calls as text on a 15-character dot matrix screen. Works with TCP-IP and provides audio alerts. Can be configured to display specific call types.
See more

Catalog excerpts

Air Dotmatrix Nurse Panel-1

Nurse Call Systems Air Dotmatrix Nurse Panel • Displays 4 calls simultaneously • Other calls are held in queue and shown on screen in order of priority • Adjustable 5 digits can show room and bed number • LED indicator shows call status Red – Normal Call Green – Nurse Presence Blue – Emergency / WC Call • 433 MHz wireless frequency • Can output active calls and logs to an Air Basic Reporter Software installed PC via serial port • Programmable manually using on-device buttons • Supports up to 64 Air Call Units • Audio alerts in different tones according to call type • Mute mode Technical Specification ZKRUNCWRNCSPC10 Weight Operating Voltage Operating Temperature Wireless Coverage Wireless Frequency 433 Mhz, Encrypted Communication Protocol

 Open the catalog to page 1
Air Dotmatrix Nurse Panel-2

Nurse Call Systems Air Bedside Call Unit The Air Bedside Call Unit is used in patient rooms. There are call and cancel buttons on the unit. In an emergency, a patient uses the call button to make an emergency call which appears as an alert on the Nurse Panel. Typical locations for this unit are on the walls of patient rooms and living areas. • Air Patient Handsets work through connection to this unit • Can be flush mounted and has an ergonomic design • Battery lasts up to 5000 calls • Made of high quality PC-ABS-FR Raw Materials Technical Specification ZKRUNCWRWL10100 Weight Mounting Dimensions...

 Open the catalog to page 2
Air Dotmatrix Nurse Panel-3

Nurse Call Systems Air Patient Handset The Air Patient Handset allows the patient’s condition to be reported quickly to hospital staff in an emergency situation. The device works through connection to the Air Bedside Call Unit. Easy-to-understand labels indicate the functions of the buttons. Technical Specification ZKRUNCWRHS10100 Weight Operating Temperature / Humidity 1.5 Meter Spiral Cable Reassurance Light

 Open the catalog to page 3
Air Dotmatrix Nurse Panel-4

Nurse Call Systems Air Pull-Cord Call Unit The Air Pull-cord Call Unit is used in patient bathrooms or similar areas. There is a cancel button and an emergency call pull-cord on the unit. In an emergency, the patient makes an emergency call by pulling the cord. This appears as a WC Emergency Call on the Nurse Panel. The system gives priority to WC Emergency calls and they appear before nurse calls. Technical Specification ZKRUNCWRWC10100 Weight Rope Capacity Operating Temperature / Humidity Power Supply Battery Life Wireless Range Wireless Frequency 433 Mhz Encrypted Communication Protocol

 Open the catalog to page 4
Air Dotmatrix Nurse Panel-5

Nurse Call Systems Air Over Door Light The Air Over Door Light is located above the patient room door in the corridor. Its half-sphere shape makes it easily noticeable from any angle of view. It can indicate the call status of the room with 3 main colors, red, green, and blue. It has very low energy consumption with environment-friendly LEDs. It is typically surface mounted but can also be flush mounted if preferred. • Maintenance/technical support free • Plug and play architecture • 3 different colors (red, green, blue) • Very low energy consumption • Environment friendly LEDs Technical Specification...

 Open the catalog to page 5
Air Dotmatrix Nurse Panel-6

Nurse Call Systems Signal Repeater Expands signal coverage between Air Call Units and Air Nurse Panels when necessary. There is no restriction on the number of repeaters that can be used. Requires external 5V DC Power Supply. Technical Specification ZKRHNWRREP10010 Weight Operating Temperature / Humidity Power Supply Operating Voltage Metallic grey Wireless Frequency 433 Mhz, Encrypted Communication Protocol

 Open the catalog to page 6
Air Dotmatrix Nurse Panel-7

Nurse Call Systems EC-232 The EC-232 is a plug-and-play ethernet-serial converter that you can connect to your devices or computer through RS232. You can quickly and easily relay data from an ethernet line to RS232 or from RS232 to ethernet line. This converter is designed to be easy-to-use in any layout. Entering and configuring IP addresses is enough to use the EC-232. You can connect your devices securely to the ethernet network and, and reach them through LAN, WAN, and Internet. EC-232 may work as TCP (Server/Client) or UDP (Server/Client). Technical Specification ZKRTNWEC232C100 Weight Stationary...

 Open the catalog to page 7
Air Dotmatrix Nurse Panel-8

Nurse Call Systems Technical Specification ZKRUNCIPPOSPG10 Protocol Frequency Range Receiver Type Baud Rate Paging Sensitivity Channel Spacing Frequency Deviation Frequency Stability Image Rejection Spurious Rejection Alert Tone Loudness 16 characters / line, 22 characters max Memory Capacity Battery Type Low Battery Alert Level Operating Temperature

 Open the catalog to page 8
Air Dotmatrix Nurse Panel-9

Nurse Call Systems Pager Transmitter Technical Specification ZKRUNCIPPGWR100 Protocol Operating Temperature / Humidity Frequency Range Channel Spacing Power Consumption Receiver Sensitivity Harmonic Radiation Frequency Stability Antenna Connection

 Open the catalog to page 9
Air Dotmatrix Nurse Panel-10

Nurse Call Systems Text Panel The Text Panel is a scrolling 15-character dot matrix screen. It works with TCP-IP on the network, displays the calls as text, and gives audio alerts. Based on preference it can be set to display only specific types of calls. It works with 110-240 V. Mounting Bracket Technical Specification ZKRUNCIPTXTPNL18 Weight Operating Temperature / Humidity Power Supply Power Consumption Operating Voltage

 Open the catalog to page 10
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.