1. Catalogs
  2. Klaromed
  3. Integration and Archiving systems for Operating Rooms

Integration and Archiving systems for Operating Rooms
1 /10Pages

Integration and Archiving systems for Operating Rooms

Integration and Archiving systems for Operating Rooms
1 /10Pages

Catalog excerpts

Integration and Archiving systems for Operating Rooms-1

INTEGRATION AND ARCHIVING SYSTEMS FOR OPERATING ROOMS Hospital wards Description room Treatm room

 Open the catalog to page 1
Integration and Archiving systems for Operating Rooms-2

Integration and archiving systems Integration is a piece of cake for us ment m Operating room urer of tems anufact ing sys Polish mnd archiv ation a integr

 Open the catalog to page 2
Integration and Archiving systems for Operating Rooms-3

Integration and archiving systems Next generation INTEGRATOR INTEGRATOR is a multimedia surgical system, integrated with hospital information systems, as well as an intuitive set of applications for Full HD or SD video sequences recording, developing reports on operations and remote control of many important functions in the operating room. System integrated browser for images and video sequences applies DICOM 3.0 standard. Local settings module allows creating a multi-level system platform. These solutions are designed in multilingual versions (languages available – Polish by default, as well...

 Open the catalog to page 3
Integration and Archiving systems for Operating Rooms-4

Integration and archiving systems INT.COM- control and communication module Any INTEGRATOR System version features INT.COM module, offers unlimited possibilities of the digital audio-visual communication. INT.COM module additionally offers professional supervision of different rooms. It was designed so as to provide an opportunity to observe many rooms simultaneously. The service level was maximised due to the screen level control of the touch tablet, laptop-type mobile computer, or standard PC station. The user can check and analyse the given operation unit room activity at any time. INTEGRATOR...

 Open the catalog to page 4
Integration and Archiving systems for Operating Rooms-5

Integration and archiving systems Remote control of features and equipment INT.COM application module provides operating rooms functions and equipment remote control. It can serve for the operating room monitoring and control its functions, configuration, and settings of individual devices. With the device configurations memory the operating room can be quickly adapted to the users and different surgical specialities preferences. In addition, INT.COM module provides control over: • Video cameras as Full HD and SD, • Operating theatre lamps, • Operating tables, • Matrix Video Switch Full HD and SD...

 Open the catalog to page 5
Integration and Archiving systems for Operating Rooms-6

Integration and archiving systems INT.DICOM - Browser module To provide quick search for the patient date the INTEGRATOR System offers INT.DICOM module, which ensures connections using DICOM standard. This standard is widely used in the medical world to view and use the patient information in the centralized management system HIS (Hospital Information System and RIS – Radiology Information System; INT.DICOM module featuring broker function that names patient information is easily connected to the DICOM standardbased control systems or HL7 protocol. The system features a variety of DICOM compliant...

 Open the catalog to page 6
Integration and Archiving systems for Operating Rooms-7

Integration and archiving systems INT.REC – digital recording and video configuration module INTEGRATOR in any version is equipped with an INT.REC module, used, primarily for digital audio/video repetitions, as well as quality images and Full HD and SD resolution recording and reading. Signal sources to be recorded with a highest quality offered may come from laparoscopes, endoscopes, microscopes, surgical education systems or directly from an omnidirectional camera that transmits live image from the operating room or HD/SD camera, built in the operating theatre lamp. The purpose of this solution...

 Open the catalog to page 7
Integration and Archiving systems for Operating Rooms-8

Integration and archiving systems INT.VISIO - review and display module INT.VISIO module is designed for viewing video sources and multiplex displaying on multiple monitors in the operating room. During the working session the user can choose in a simple way to switch and display the video signals. Module monitoring feature is available in a full screen mode. As an option, the user can select the INT.VISIO module to adjust with the input/output switches of 4x4, 8x8, or 16x16 sizes, which allows switching the Full HD video signal sources. Video switch distributes the video signal around the room...

 Open the catalog to page 8
Integration and Archiving systems for Operating Rooms-9

Integration and archiving systems INT.CONF – videoconference module INT.CONF videoconference module solution utilizes the videoconference open standards to provide the solutions of various classes to meet the requirements of the user. The user can choose between low budget and high-end solution based on the reputable suppliers’ components, for example. CISCO (Tandberg), consisting of a professional video camera solution, hardware streaming encoder/decoder and large panoramic display. INTEGRATOR System features INT.CONF module with a hardware-based videoconference streaming, which can be controlled...

 Open the catalog to page 9
Integration and Archiving systems for Operating Rooms-10

Integration and archiving systems INT.PACS - PACS server module INT.PACS is an INTEGRATOR system module that meets all basic functions of the PACS server, such as storage and requests handling. The server also handles typical PACS modalities: CT, CR, US, as well as C-STORE, SCP/SCU, and Query/Retrieve methods: C-MOVE SCU/SCP, C_GET SCU/SCP. INTEGRATOR system can display the “Worklist” with the possibility of reading all the data associated with HIS/RIS hospital information system (such as patient identification, examinations, graphics, examination periods, patient examination lists). The mandatory...

 Open the catalog to page 10

All Klaromed catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.