VEGA PROSTHETIC·SYSTEm
2Pages

{{requestButtons}}

Catalog excerpts

VEGA PROSTHETIC·SYSTEm - 1

IMPRESSION TAKING REFERENCE LIST General observations: ■ Individual trays suitable for each case should be used for making the impressions. ■ Likewise, quality materials are to be employed, following the manufacturer's instructions for use. ■ Check that the implant connection is clean [blood, residues, etc.]. ■ Take the necessary precautions to prevent elements from becoming detached in the oral cavity, with the risk of swallowing or aspiration of same. 18 09 09 In the case of single implants, check that the flat surfaces are perfectly registered in the impression. 18 09 10 ■ Free the zone of the screw by removing excess impression material before it sets. ■ Depending on the relation with respect to the antagonist and adjacent teeth, and the gingival height, select the correct transfer (short or long, depending on product availability). ■ In the latter case, correct seating of the transfer in the implant and/or abutment is necessary if the direct impression technique is chosen. MODEL POURING Check the stability of the replica-transfer unit in the impression before model pouring Quality materials must be used, following the manufacturer's instructions for use. 18 09 09 MV TRANSFER [CLOSED TRAY] 18 09 31 MV ANALOG 18 09 10 MV TRANSFER [OPEN TRAY] 18 10 85 MV ANATOMICAL STRAIGHT ABUTMENT [2.0mm] 18 10 86 MV ANATOMICAL STRAIGHT ABUTMENT [3.0mm] 18 10 87 MV ANATOMICAL STRAIGHT ABUTMENT [4.0mm] 18 10 84 MV ZERO ABUTMENT 18 10 83 MV TITANIUM TEMPORARY ABUTMENT [SINGLE] 18 10 88 MV TITANIUM BASE ABUTMENT [SINGLE] 18 11 03 MV STAR SCREW 18 10 92 MV CoCr ABUTMENT [SINGLE] 18 10 90 MV GOLD ABUTMENT [SINGLE] 10 15 01 ACCESS HOLE REAMER 10 11 09 ACCESS HOLE PROTECTOR JDTWKL JDTORQUE® TORQUE WRENCH 10 08 11 STAR TORQUE WRENCH ADAPTER 10 08 11 L ALONG STAR TORQUE WRENCH ADAPTER 10 08 14 EXTRA LONG STAR TORQUE WRENCH ADAPTER MV ABUTMENTS ■ General observations: Tightening on the abutments is to be avoided [maximum torque 5 Ncm] during the prosthesis manufacturing process until definitive insertion of the prosthesis, when the applicable torque should be 25 Ncm. ■ It is important to not exceed a torque of 25 Ncm. ■ In the case of provisional restorations, the torque for fitting is 15 Ncm. GOLD BASE ABUTMENT 18 10 90 An alloy is to be chosen for overcasting according to standards ISO 9693-1, ISO 22674. DESIGN PARAMETERS TO BE USED IN THE FINAL RESTORATION Maximun length of the restoration 14 mm Minimum wall tickness 0,45 mm *do not out the piece Minimum post height 3,5 mm* below 3.5 mm to avoid Maximum angulation 30° exposing the metal Not suitable for screwed multiple prosthesis. [See metal specifications.] Co-Cr BASE ABUTMENT 18 10 92 An alloy is to be chosen for overcasting according to standards ISO 9693-1, ISO 22674 DESIGN PARAMETERS TO BE USED IN THE FINAL RESTORATION Maximun length of the restoration 14 mm Minimum wall tickness 0,45 mm *Do not cut the piece Minimum post height 3,5 mm* below 3.5 mm to avoid Maximum angulation 30° exposing the metal Not suitable for screwed multiple prostheses. [See metal specifications.] PROVISIONAL ABUTMENTS 18 10 83 These abutments are made of titanium and must be trimmed using adequate drills. Provisional restorations are to remain in the mouth for a maximum of 90 days. The torque for fitting is 15 Ncm. All KLOCKNER® IMPLANT SYSTEM products comply with the laws and regulations applicable to medical devices, such as: European directives MDD 93/42/ECC modified by 2007/47EC ■ Regulations of the United States FDA 21CFR 820 ■ Quality standards EN ISO 13485 and other applicable standards and regulations. PROSTHETIC PLANNING KIT The parts included in the prosthetic planning kit must be cleaned, disinfected and sterilized if intended for use in the mouth (steam sterilization at 134°C during 4 min.). The abutments included in the prosthetic planning kit are not suitable for the manufacture of dental prostheses. G A@mv TITANIUM BASE The titanium base is used for designing ceramic prosthesis with the CAD/CAM system. The titanium base should be used to produce a personalized structure, combining an optimum anatomical contour with esthetic finishing in the supragingival zone. PROSTHETIC-SYSTEM KUXKner^p,ant system Onlyfor USA: SOADCO S. L.isamanufacturerof surgical-medical material, specifically dental implants and related surgical-medical products. KLOCKNER of NorthAmerica, incisthe official distributor in USA. SOADCOS. L., KLOCKNER of NorthAmerica and/orotherofficial distributors do not practicemedicine or dentistry and thereforedonot recommendeithersurgical techniques or dental-medical equipmentfor patients. SOADCO S. L, KLOCKNER of North America, inc. and/orother official distributors do not guarantee a particular result or benefits arising from theuseof such dental-medical equipmentmanufactured and/orsoldbythemselves, anddecline/refuse any responsibility regarding theuseofthematerial basedonthe interpretation of the information described in this document, because a particular outcome cannot be guaranteed. Anywitness, opinion or instruction described inthis document and distributed to any healthcare professional, clinician, researcher, or any qualified personnel are only theirtestimony, opinions, or instructions. These are nottestimony, opinions, or instructionsfrom employeesof SOADCOS. L., KLOCKNER of NorthAmerica, inc. and/orotherofficial distributors. Therefore, SOADCO S. L., KLOCKNER ofNorthAmerica, inc. and/or other official distributors arenotresponsibleforanyclaimor statementmadebysuch parties. Theproductsdescribed inthis documentarefortheiracquisitionanduse only by dental-medical professionalsappropriatelytrained and qualifiedinthisfield andmust not be resold. The devices described in thisdocumentare manufactured by: SOADCOS. L, Avgda. Fiter i Rossell, 4 bis local n° 2 escaldes-engordany [Andorra] and distributed inusaby KLOCKNER of North America, inc. 175sw 7 street, units 1103-1104 MiamiFl -33130 [USA] The useand/orselectionof aninappropriatetreatmentof anymedicaland/orsurgical materialsdescribed in thisdocument, issolely responsibility of theuserof suchmaterial. WARNING NOT ALL KLOCKNER® IMPLANTS SYSTEM PRODUCTS ARE AVAILABLE IN EVERY COUNTRY implant system

Open the catalog to page 1

All KLOCKNER catalogs and technical brochures

  1. NON-TOUCH

    2 Pages