1. Catalogs
  2. KNAUER
  3. Pump P 2.1S/P 4.1S Instructions

Pump P 2.1S/P 4.1S Instructions

Pump P 2.1S/P 4.1S Instructions
1 / 60 PagesView full catalog

Pump P 2.1S/P 4.1S Instructions

Product catalog summary
Product Overview
The AZURA® Pump P 2.1S and P 4.1S are designed for use in analytical or preparative applications, transporting solvents or samples through an HPLC system. They are suitable for various analyses, including biochemical and pharmaceutical.

Features
The pumps offer flow rates from 0.001 to 50 ml/min with pressures up to 400 bar, using dual-piston technology for constant flow rates. The P 4.1S model includes a pressure sensor and emergency stop feature. Control is possible via keypad or chromatography software.

Pump Heads
Available in stainless steel, Hastelloy-C, or ceramic inlays, with sizes of 10 ml or 50 ml, labeled with maximum capacity and material type.

Safety Instructions
Users must have knowledge of liquid chromatography and adhere to safety measures, including wearing protective clothing and ensuring proper ventilation. The device should not be used in explosive atmospheres without protection.

Setup and Power Supply
The device should be placed on a level surface, away from direct sunlight and drafts, requiring a power supply of 100-240 V AC. Only KNAUER-approved accessories should be used.

Unpacking and Installation
Check for transport damage and ensure all components are present. Integrate the device into the HPLC system by connecting the appropriate components.

Legal and Disposal Information
Includes sections on transport damage, warranty conditions, and disposal instructions, emphasizing compliance with regulations.
Initial Startup and Operation
Detailed instructions for setting up and operating the pumps, including menu navigation, setting flow rates, and adjusting pressure settings. The pump can be controlled via device keyboard, chromatography software, or analog control.

Maintenance and Care
Regular maintenance is recommended to ensure optimal performance. Tasks include replacing pump heads and check valves, with detailed instructions provided.

Technical Data
The pump is a dual-piston type with a flow rate range of 0.001-10 ml/min for a 10 ml pump head and 0.01-50 ml/min for a 50 ml pump head. It supports isocratic HPLC and can be expanded to a binary high-pressure gradient system.

Chemical Compatibility
Information on the chemical resistance of materials like PEEK, PET, and polyimide used in the device, highlighting the importance of avoiding certain chemicals that can cause damage.
Installation Qualification (IQ)
Part of the quality management system, ensuring device functionality and proper installation. Includes checks for transport damage, delivery completeness, and proper labeling.

Functionality Tests and Troubleshooting
Regular checks include inspecting cabling, screw fittings, air in supply lines, and device leaks. Troubleshooting common problems involves checking power connections, venting screws, and cleaning or replacing check valves.

Material Specifications and Compatibility
Details on materials used in the pump, such as stainless steel and PEEK, and their chemical compatibility. Includes information on non-metals and metals used in the device.

Legal and Warranty Information
Warranty covers material or design defects, excludes unauthorized changes and certain damages. Contact information for technical support and warranty claims is provided.
See more

Catalog excerpts

Pump P 2.1S/P 4.1S Instructions-2

Note:  For your own safety, read the instructions and follow the warnings and safety information on the device and in the instructions. Keep the instructions for future reference. Note:  In case you require this instruction in another language, please submit your request including the corresponding document number via e-mail or fax to KNAUER. Support: Do you have questions about the installation or the operation of your instrument or software? International Support: Contact your local KNAUER partner for support: www.knauer.net/en/Support/Distributors-worldwide Support in Germany (Austria & Switzerland...

 Open the catalog to page 2
Pump P 2.1S/P 4.1S Instructions-3

Table of contents 1.  Product information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1  Device overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.3 Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.3.1  Front...

 Open the catalog to page 3
Pump P 2.1S/P 4.1S Instructions-4

5.7.5  Controlling several systems separately in the LAN . . . . . . . . . . . . . . . . . . . . 15 5.7.6  Firmware Wizard: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 5.7.6.1  Firmware Wizard: Assign static IP address . . . . . . . . . . . . . . . . . . . . . . . 15 5.7.6.2  Firmware Wizard: Assign dynamic IP address . . . . . . . . . . . . . . . . . . . . 16 5.7.6.3 APIPA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 6.  Initial startup . . . . . . . . . . . . . . . ....

 Open the catalog to page 4
Pump P 2.1S/P 4.1S Instructions-5

10.  Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 10.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 10.2 Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 10.3 Technical parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 10.4 Dimensions . . . . . . . . . . ....

 Open the catalog to page 5
Pump P 2.1S/P 4.1S Instructions-7

1.  Product information 1.1  Device overview The HPLC pumps P 4.1S/ P 2.1S with pump heads can be used as feed pumps or dosing pumps in analytical or preparative applications. Pumps transport solvents or dissolved samples through the HPLC system. Note:  Only use the device for applications that fall within the range of the intended use. Otherwise, the protective and safety equipment of the device could fail. Operating ranges The device can be used in the following areas: Biochemical analyses Food analysis Pharmaceutical analysis Environmental analysis Chemical analysis Dosing applications 1.3.1 ...

 Open the catalog to page 7
Pump P 2.1S/P 4.1S Instructions-8

Analytical pump head with a flow rate range from 0.001 – 9.999 ml/min and a pressure of up to 400 bar Analytical pump head with a flow rate range from 0.01 – 50 ml/min and a pressure of up to 150 bar Dual-piston technology for constant flow rates Setting a limit for minimum and maximum pressure to protect the HPLC columns and to avoid a dry run of the pump (only P 4.1S) Emergency stop, independent from control with chromatography software The pump can be controlled with the keypad in standalone mode or with the chromatography software. The pump heads can be easily removed and replaced via four...

 Open the catalog to page 8
Pump P 2.1S/P 4.1S Instructions-9

Legend 1 rate Flow 2 Material Fig. 4 Pump head with inlays 2.  Scope of delivery Note:  Only use spare parts and accessories made by KNAUER or a company authorized by KNAUER. 24 V power adapter with power cable Instructions (German/English) AZURA accessories kit P 2.1S/P 4.1S accessories kit Declaration of conformity 3.  Basic safety instructions 3.1  Target group The document is intended for people who have completed at least a training as a chemical laboratory assistant or a comparable training path. The following knowledge is required: Fundamental knowledge of liquid chromatography Knowledge...

 Open the catalog to page 9
Pump P 2.1S/P 4.1S Instructions-10

Basic safety instructions Safety equipment When working with the device, take measures according to lab regulations and wear protective clothing: Safety glasses with side protection Protective gloves Lab coat What does the user have to consider? All safety instructions. The environmental, installation and connection specifications When working with solvents, make sure the room is well-ventilated. National and international regulations pertaining to laboratory work Original spare parts, tools, and eluents made or recommended by KNAUER Good Laboratory Practice (GLP) Accident prevention regulations...

 Open the catalog to page 10
Pump P 2.1S/P 4.1S Instructions-11

Basic safety instructions Where is use of the device prohibited? Never use the system in potentially explosive atmospheres without appropriate protective equipment. For more information, contact KNAUER Technical Customer Support. Taking the device safely out of operation The device can be taken out of operation completely at any time by turning off the power switch of the power supply or disconnecting the supply connection. Only have the device opened by a KNAUER Technical Customer Service representative or a KNAUER authorized company. Possible dangers that can arise from a device are classified...

 Open the catalog to page 11
Pump P 2.1S/P 4.1S Instructions-12

4.  Symbols and signs The following table explains symbols and labels which are used on the device or in the instruction: Symbol Meaning The device complies with the product-specific requirements of the European Union. The device complies with the product-specific requirements of the United Kingdom. High-voltage hazard Electrostatic-discharge hazard Testing seals in Canada and the USA at nationally recognized testing centers (NRTL). The certified device or system has successfully passed the quality and security tests. Notes provide useful tips and valuable information. AZURA® Pump P 2.1S/P 4.1S...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.