1. Catalogs
  2. KNF
  3. N 938 SERIE VACUUM PUMPS

N 938 SERIE VACUUM PUMPS

N 938 SERIE VACUUM PUMPS

N 938 SERIE VACUUM PUMPS

Product catalog summary
Advantages
  • Customized motor parameters for specific needs.
  • Reliable performance across various conditions.
  • High pumping speed throughout the entire pressure and vacuum range.
  • Robust and compact design.
  • Options for analog or digital speed control.
  • Capability to read pump parameters.
  • Incorporated safety functions.
Possible Areas of Use
  • Fuel cells: Hydrogen recirculation.
  • Measurement technology: Sampling pump for exhaust gases.
  • Medical technology: Diagnostics and histology.
  • Vacuum technology: Pick & place applications.
  • Laser technology: Chamber evacuation.
Performance Data
  • Series models: N 938 and N 938.1.2.
  • Material design: Aluminum anodized, with optional PPS or Stainless steel.
  • Diaphragm: EPDM, with optional EPDM/PTFE-coated.
  • Valves: FPM, with optional FFPM.
  • Flow rate at atmospheric pressure: 9 – 35 l/min for N 938, 13 – 53 l/min for N 938.1.2.
  • Ultimate vacuum: 160 mbar abs./4.7 inHg for N 938, 140 mbar abs./4.1 inHg for N 938.1.2.
  • Max. operating pressure: 1.0 bar rel./14.5 psig.
  • Permissible ambient and media temperature: +5 °C to +40 °C / 41 °F to 104 °F.
  • Weight: 2.1 kg/4.6 lbs for N 938, 3.4 kg/7.5 lbs for N 938.1.2.
Electrical Data
  • Voltage: 24 V.
  • Motor: Brushless DC motor.
  • Protection class: IP 20.
  • Power: 82 W for N 938, 94 W for N 938.1.2.
  • Maximum current draw: 3.4 A for N 938, 3.85 A for N 938.1.2.
Spare Parts and Accessories
  • Spare parts kits available for both models, including diaphragms and valve plates.
  • Accessories include silencer/inlet filter, hose connector, and vibration damping components.
Additional Information
  • Performance values are determined under test conditions and may vary based on usage conditions and system parameters.
  • Digital customization allows for quick adaptation to customer systems through firmware parameterization.
  • KNF reserves the right to make technical changes without notice.
See more

Catalog excerpts

N 938 SERIE VACUUM PUMPS-1

ADVANTAGES • Customized motor parameters • High pumping speed over the entire pressure and vacuum range • Analog or digital speed control • Readout of pump parameters • Safety functions • Fuel cells -recirculation of hydrogen • Measurement technology -sampling pump for exhaust gases • Medical technology -diagnostics and histology • Vacuum technology -pick & place applications • Laser technology -evacuation of the chamber 11 expanded performance available upon request 3) Flow rate determined at 20 °C, 1000 mbar abs. (Pressure 0 to 1000 mbar abs. in accordance with ISO 21360

 Open the catalog to page 1
N 938 SERIE VACUUM PUMPS-2

N 938 AN.29 DC-B PERFORMANCE DATA Series model Flow rate at atm. pressure (l/min)3) 9 – 35 Ultimate vacuum (mbar abs./inHg) 160/4.7 bar rel relative to 1013 hPa Flow rate determined at 20 °C, 1000 mbar abs. (Pressure 0 to 1000 mbar abs. in accordance with ISO 21360/ISO 8778) N 938 AN.29 DC-B | PUMP UP TIME FOR 20 LITER VESSEL N 938 AN.29 DC-B 7.10736 - Flow rate - N938AN.29DC-B - 01 - ib - 21-Dec-2023 pressure in hPa 800 N 938 AN.29 DC-B | PUMP DOWN TIME FOR 20 LITER- 20VESSEL 7.10737 - Auspumpzeit - N938AN.29DC-B Liter - 00 - cq - 25-May-2021 0 pump down time in min flow rate in l/min

 Open the catalog to page 2
N 938 SERIE VACUUM PUMPS-3

N 938.1.2 AN.29 DC-B PERFORMANCE DATA Series model Flow rate at atm. pressure (l/min)3) 13 – 53 Ultimate vacuum (mbar abs./inHg) 140/4.1 bar rel relative to 1013 hPa Flow rate determined at 20 °C, 1000 mbar abs. (Pressure 0 to 1000 mbar abs. in accordance with ISO 21360/ISO 8778) N 938.1.2 AN.29 DC-B | PUMP UP TIME FOR 20 LITER VESSEL N 938.1.2 AN.29 DC-B 7.10739 - Flow rate - N938.1.2AN.29DC-B - 01 - ib - 21-Dec-2023 pressure in hPa 800 N 938.1.2 AN.29 DC-B | PUMP7.10740 DOWN TIME FOR 20 LITER -VESSEL - Auspumpzeit - N938.1.2AN.29DC-B 20 Liter - 00 - cq - 25-May-2021 0 pump down time in min...

 Open the catalog to page 3
N 938 SERIE VACUUM PUMPS-4

DIGITAL CUSTOMIZATION Thanks to digital technology, this pump can be quickly adapted to the customer's system This is done by parametrizing the firmware of the motor at KNF. KNF reserves the right to make technical changes without notice. KNF 01/2024. www.knf.com The performance values for the series models shown on this data sheet were determined under test conditions. The actual performance values may differ and depend in particular on the usage conditions and therefore on the specific application, on the parameters of the components involved in the user’s system and on any technical modifications...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo
MedicalExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. MedicalExpo is an entity of VirtualExpo Group.