Comprehensive Pulmonary Function Testing ENSURE YOUR LAB IS AN ESSENTIAL PART OF ENHANCING RESPIRATORY PATIENT CARE KoKo Px empowers you to enhance respiratory care by combining reliable, industry-leading PFT performance with seamless review, interpretation, and EMR interoperability to easily produce and distribute the highest quality, ATS-compliant test results in your modern, connected practice. INCREASE EFFICIENCY IMPROVE TEST QUALITY Industry-proven reliability with an uptime guarantee ° Highest accuracy (1% to scale) of any PFT system ° and performance assurance over the life of the device Minimal setup and test time increases productivity ° Compact, ergonomic, touch-screen workstation ° Inbox worklist eliminates the need to search ° Verifiably accurate across a wide flow range and ° environmental conditions Automated quality checks and test grading ° Collect and consolidate virtually any data types with ° patient visit Real-time flow/volume and volume/time curves ° Real-time feedback and coaching of test procedure ° Securely share data across rooms or clinics ° Central standardization and configuration ° Lifetime flow sensor significantly lowers costs ° ENHANCE PATIENT COMFORT & COMPLIANCE Shortest test times in the industry ° Ultra-low breathing resistance ° Real-time effort feedback to reduce number of ° efforts needed Filters and mouthpieces comfortable for adults and ° children ° Target-adjusted, photo-realistic incentive graphics STREAMLINE PHYSICIAN ACCESS Create trend graphs for longitudinal analysis ° Comprehensive, customizable reporting ° Automate transmission of test results to care ° providers via Iris™ Remote and dedicated physician workstations ° EMR/HIS connectivity

Open the catalog to page 1
KoKo PFT Systems - 2

INNOVATIVE TECHNOLOGY FROM THE PFT EXPERTS ACCURATE, CONSISTENT RESULTS KoKo Px’s advanced iFlow™ flow sensor technology provides the highest accuracy (1% to scale) of any PFT system, surpassing the industry standard, enabling identification of smaller changes in lung function sooner. This dramatically enhances diagnostic precision, treatment planning, and monitoring value. Test patients using the same clinicallyproven, verifiably accurate flow sensor for the life of the system, ensuring more consistent, reliable results from test to test, requiring fewer efforts to get usable results....

Open the catalog to page 2
KoKo PFT Systems - 3

Enhance Patient Comfort PROVEN EASIER TO MEET MIN TESTING STANDARDS FOR REPEATABILITY KoKo Px’s industry leading accuracy and precision, carefully engineered testing sequences, and minimal breathing circuit resistance enhance patient comfort while minimizing the patient’s effort required to meet repeatability criteria. This ensures reliable test results faster for every exam, and compliance with even the most challenging subjects. Patient comfort is determined by breathing resistance and test time. KoKo Px enhances patient comfort by minimizing both. INSTANT, PRECISION GAS ANALYSIS COMES...

Open the catalog to page 3
KoKo PFT Systems - 4

EMPOWER YOUR LAB WITH INTUITIVE, STREAMLINED SOFTWARE Increase Efficiency ° Unique inbox workflow routes patient/ visit data so it is accessible to various healthcare providers when and where they need it Inbox worklist provides instant access to patient visits without the need to filter or search Tests are graded regarding acceptability and reproducibility eliminating guess work ° Search, create new, or edit existing ° Create new order or visit, if needed ° Shortest test times in the industry with immediate test starts, realtime sensors, fast gas sampling, and combined maneuvers, improving...

Open the catalog to page 4
KoKo PFT Systems - 5

WITHIN-TEST FEEDBACK VALIDATED TO MEET ATS GUIDELINES ATS/ERS quality checks provide feedback regarding test-specific acceptiblity criteria Automated test quality checks provide immediate test-specific feedback making it easy to obtain acceptable and repeatable results. This within-test quality feedback has been validated to meet ATS guidelines so you know the data is representative of the patient’s best efforts and highly comparable to the conditions with which the predicted values were derived. CALIBRATION OPTIMIZATION KoKo Px software automatically identifies variability with calibration...

Open the catalog to page 5
KoKo PFT Systems - 6

SCALABLE & EXTENSIBLE SOLUTIONS FOR COLLABORATIVE CARE MULTI-SOURCE DATA IN ONE LOCATION The Iris™ Integrated Respiratory Information System brings relevant respiratory data together in one place, empowering physicians to efficiently analyze and optimally diagnose, stage, and manage respiratory disease. Iris lets you quickly and easily share real-time information and updates with key members of a patient’s care team, enabling the most informed clinical decisions, leading to enhanced outcomes and lower costs. CENTRAL STANDARDIZATION & CONFIGURATION Increase Efficiency & Reduce Costs °...

Open the catalog to page 6
KoKo PFT Systems - 7

DEDICATED PHYSICIAN & PRACTICE MANAGEMENT WORKSTATIONS Physicians can easily review and interpret patient test data based on the complete picture (including patient reported data and priors) and generate final reports authenticated with a true digital signature at a workstation designed specifically for physicians. Associating interpretations directly with the report before sending along to the EMR ensures your findings are viewed in context by other healthcare providers. Streamline Physician Access Physicians can quickly review and digitally sign test results from a pre-populated worklist...

Open the catalog to page 7
KoKo PFT Systems - 8

PERFORMANCE SPECIFICATIONS Tests Performed Tests Performed Forced Vital Capacity  Vital Capacity Slow Challenge  Ventilation Maximal Voluntary Pre/PostChallenge – Chemical, Exercise  (Dosimeter Optional) n Capacity – SB & 3EQ  Pre- & Post- Bronchodilator Evaluation Lung Volumes – CH4  Diffusion Capacity – Single Breath & 3-EQ Lung Volumes – N2 Single Breath Methane Washout Lung Volumes Lung Volumes – Pleth Option Option Maximum Inspiratory & Expiratory Pressures Option Washout Lung Volumes – Option Multiple & Single Breath -Closing Volumes Closing Volumes Plethysmography Lung Volumes...