CR Regius Sigma.II

CR Regius Sigma.II

CR Regius Sigma.II

Product catalog summary
Specifications
The REGIUS SIGMA 2 is a compact and lightweight direct digitizer with dimensions of W510×D610×H355 mm and a weight of approximately 28 kg. It operates with a power supply of 100 VA max during operation and 20 VA when not in use. The device functions optimally within a temperature range of 10-30 °C and humidity levels of 15-80% RH without condensation.

Readable Media
The device supports REGIUS CASSETTE RC-300 and REGIUS PLATE FP-1S in various sizes, including 14"×17", 14"×14", 11"×14", 10"×12", 8"×10", 24×30 cm, 18×24 cm, and 15×30 cm.

Performance
The REGIUS SIGMA 2 offers two sampling pitches: 87.5 μm and 175 μm, achieving a maximum resolution of 4,020×4,892 pixels for 14"×17" at 87.5 μm. It supports a digital gradation level of 4096 levels (12-bit) and can process up to 60 plates per hour at 175 μm.

Features
The device includes a single insertion/ejection slot and utilizes Konica Minolta's Integral Processing for optimal diagnostic image quality. It supports high-resolution imaging with pixel sizes of 87.5 μm and 175 μm.

Environmental and Energy Efficiency
The REGIUS SIGMA 2 is environmentally friendly, with energy consumption reduced to 100 VA, significantly lower than previous models. It boasts a reduced carbon footprint with CO2 emissions cut by over 64% compared to conventional CR systems.

Software and Workflow
The ImagePilot software integrates CR image acquisition and PACS functionality, providing a complete workflow solution. It supports multi-touch displays for easy operation and offers over 100 functions, including annotation, scaling, and image tools. The software also facilitates DICOM image communication, NAS/DVD backup, and PDI output for data sharing.

Data Management
The ImagePilot server can manage over 200,000 patients and supports seamless integration with EMR and RIS systems. It allows for manual or automated patient registration and can archive up to 300,000 images with expandable storage options.

Conclusion
The REGIUS SIGMA 2, combined with ImagePilot software, offers a compact, efficient, and environmentally friendly imaging solution suitable for clinics, imaging centers, and small hospitals, maintaining high image quality and reliability.
See more

Catalog excerpts

CR Regius Sigma.II-1

COMPACT Konica Minolta's Ultra-Compact CR The REGIUSΣ II is Konica Minolta's smallest and lightest CR. The desktop CR has a footprint of only 0.31 m² and weighs a mere 28 kg. Environmentally friendly Energy consumption has been reduced to 100 VA- about the same as a household light bulb. That's one tenth the power of the smallest film processor. The powerful REGIUSΣ II achieves a high throughput of 60 plates/hour (maximum). It provides a smooth and stress-free workflow. Outer Dimensions/ Weight W510×D610×H355 mm / Approximately 28 kg Power Supply Conditions 100 VA max during operation: 20 VA when not in use. Operating Conditions Temperature : 10-30 °C Humidity : 15-80 %RH (No Condensation) Digital Gradation Level 4096 levels (12bit) Processing Capability Up to 60 plates / hour (14"×17" / 175 μm) HIGH QUALITY REGIUS SIGMA2 Outer Dimensions Integral Processing The REGIUS Σ II supports pixel sizes of 87.5 μm and 175 μm for all cassette sizes, achieving a maximum resolution of 4020x4892 pixels (14”x17” at 87.5 μm). Integral Processing - the result of Konica Minolta's vast imaging experience is a robust algorithm that produces the optimum diagnostic image automatically. This patented technique greatly simplifies X-ray image acquisition while delivering incredibly consistent image quality and virtually eliminating retakes. High Resolution Slots Insertion / ejection slot × 1 Bone Extraction Reference S Value Determination Image Output Universal Algorithm Signal Value SMART CONSOLE All-in-One! The ImagePilot software combines CR image acquisition and PACS functionality. It is a complete work flow solution for clinics, imaging centers, and small hospitals. From one GUI, user s can acquire, review, distribute and archive patient images. Easy Control ImagePilot supp or t s a multi-touch display for the easiest operation. More than 100 functions and features are literally at the tips of your fingers. Brand Name Type Model : REGIUS ΣII : DIRECT DIGITIZER : REGIUS SIGMA 2 * Specifications are subject to change without prior notice. • Lowest Weight CR (approx. 28 kg) • Power consumption is less than one tenth of prior models. • Smallest carbon footprint - CO2 emissions reduced by more than 64 % (Calulated at lifecycle, compared to our conventional CR)

 Open the catalog to page 1
CR Regius Sigma.II-2

From patient registration to long term archive, KonicaMinolta provides a complete workflow. Konica Minolta has been a CR technology leader since 1996, consistently designing, developing, and delivering innovative solutions. The REGIUS Σ represents the sum Ⅱ of this experience. REGIUS ΣⅡ delivers a compact and affordable imaging solution that maintains the superior image quality and reliability expected from our REGIUS family of products. Combined with the redesigned ImagePilot software, the REGIUS ΣⅡ provides simple operation and smooth workflow to a wide range of medical practitioners. Images...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.