>ER R?LERT FERROMAGNETIC THREAT DETECTION, LOCATION, RECORDING & ANALYSIS Kopp provided pre-programmed Laptop Computer with installed FerrAlert DATA analysis software WI-FI Username Password Enabled ONLY Kopp provided Communication Router Automatically locates and logs ferromagnetic threats for: 4 4 Root Cause Analysis investigations Provides a photographic log of each event Does not interrupt workflow or rely on self-reporting Provides reports and analysis of safety trends Easily implemented connectivity and expandability Reports can be shared throughout the entire hospital system PAGE 1 of 4
Open the catalog to page 1
>ER R?LERT THREAT DETECTION AND LOCATION WITH: ™ FerrAlert™ provides the most reliable detection and prevention of ferromagnetic threats from entering the MRI room (Zone IV). FerrAlert™ detectors are recognized to be the most accurate ferromagnetic detectors for MRI, due to their exclusive object location-specific feature. FerrAlert™ Unique Features: Intelligent Pre-Warning on approach WELL OUTSIDE the magnet room Instantly PINPOINTS LOCATION of the ferromagnetic threat NO INTIMATE CONTACT required Alarms are visible from INSIDE and OUTSIDE the magnet room Visual Warning activated on the...
Open the catalog to page 2
The imaging system, >ERR?LERT F.I.L.M . ,(F.I.L.M.) is configured and positioned in a location to allow simultaneous viewing inside the MRI scanner room as well as the approach to the scanner room. Shown below are a few sample of images from one date and time stamped log: Visual Advance Pre-warning: All 48 red alarm lights of FerrAlert™ HALO II PLUS are activated on the approach of a ferromagnetic wheelchair WELL OUTSIDE scanner room. No Audio alarm sounds at this time. Audio alarm and F.I.L.M. are activated: When the Photoelectric sensor of the FerrAlert™ HALO II PLUS is crossed, the...
Open the catalog to page 3
ANALYSIS Daily report From the DASHBOARD, tab the date of 01/01/18 is selected. It is noted that non-ferrous transports were implemented. All recorded events for all F.I.L.M. cameras are listed. Incidents From the VIEW INCIDENTS tab, incidents with no injuries, for the date range of 1/1/18 to 1/23/18 have been selected. Other information such as object type and whether damage occurred is listed. >ERR?LERT DATA >ERR?LERT DATA Tracking Trends From the STATISTICS tab, a date range of 9/1/17 to 6/11/18 was selected. Occurrences which involved patient transports and which caused injuries and...
Open the catalog to page 4All Kopp Development catalogs and technical brochures
-
GaussAlert™
2 Pages
-
FerrAlert ™Target Scanner
2 Pages
-
FerrAlert™ SOLO
4 Pages
-
1
4 Pages