UV STERIL COIL Cod. KC236
2Pages

{{requestButtons}}

Catalog excerpts

UV STERIL COIL Cod. KC236 - 1

UV S t e ri l A i r S y s t e m UV Steril Air System Airborne Disinfection Deviiices v c es Airborne Disinfection Dev ce Patented & Certified Conforms with the following standard Medical equipment 93/42 CEE Group B Class I ref . EN 55011 THE AIR DISINFECTION THROUGHT THE ULTRAVIOLET RAYS UVGI TECHNOLOGY AIR DISINFECTION UNIT FOR FAN COIL AIR DISINFECTION UNIT FOR FAN COIL UV STERIL COILS is applied to the fan coils. UV STERIL COILS is provided by special lamps with mercury-vapour with low pressure The lamp issue UVGI with short waves of 253,7 nm for a good germicidal action. The glass of the tube is used like a filter for the ozone line (185nm) UV STERIL COILS uses concentrated levels of ultraviolet germicidal irradiation (UVGI) for the destruction of the microorganisms that are in the air. UV STERIL COILS has got a special electronic counter which monitors the effective life of the special germicidal lamps UV STERIL COILS is complete with an electronic generator “ionic source germicidal” which enriches the air of negative ions ( very healthy) UV STERIL COILS is applied on known parameters of the fan coils. A dedicated software cod. 3332 consents to establish the UVGI necessary to obtain a microbiological reduction till 99,999%. UV STERIL COILS can be put instead of the fan coils filter and it uses the fan coils ventilation. The filter extracted from the fan coil is put in the right place of UV STERIL COILS. The air passes firstly a dust filter where the biggest pollutants are stopped thus, avoiding dirtying the germicidal lamps. Then it passes through the germicidal lamp that, thanks to the emission of UVGI, they destroy the microorganisms that are in the air. At last, a ionic source eliminates the smaller particles that are still in the air(the most harmful) and at the same time the air is full of negative ions (good for our health). The air is expelled out by the fan coil with an efficacy microbiological reduction. The progressive and continuos treatment of the air allows to maintain the environment without bacterial contamination. PREVENTION FROM AIRBORN INFECTIONS PROBLEMS PREVENTION FROM AIRBORN INFECTIONS PROBL

Open the catalog to page 1
UV STERIL COIL Cod. KC236 - 2

AIRBORNE DISINFECTION UNIT FOR FAN COIL AIRBORNE DISINFECTION UNIT FOR FAN COIL TECHNICAL DATA Rated voltage Electrical connection Electronic power Rated flow Operation Lamp Wavelength Germicidal Irradiation Level of air sterilization Life of UV-C tubes Filter control Equipment Ozone Installation 230V 50/60 Hz switch –on/off of fan coil high frequency for 200 - 400 m3/h continuos n.2 x 36W UV-C PL-L 253,7 nm 28.200 µW/cm2 99,99% refers to germicidal UV 253,7 nm radiation for the destruction Mycobacterium Tubercolosis 6000 hours 300 hours N. 1 Filter Electronic counter for filter and tube...

Open the catalog to page 2

All KOVER SRL catalogs and technical brochures

  1. AIR GERM UV

    2 Pages

  2. kc260

    2 Pages