
Catalog excerpts

Compact Table Top Centrifuge Compact Table Top Refrigerated Centrifuge
Open the catalog to page 1
Small-footprint, and loaded with features Two Types of Swinging Bucket 4,000rpm Rotor • Multiple swinging bucket rotors for 24 x 15mL tubes • Plate rotor for 2 x PCR plates / 6 x Micro-plates / 2 x Deep-well plates The small footprint Model 2420 can centrifuge 24 x 15mL tubes at 4,000rpm. Compact size, only 35cm (W) x 42cm (D) x 32cm (H) Rotor for PCR plates / Micro-plates / Deep-well plates can be used. 2 x PCR plates, 6 x Micro-plates or 2 x Deep-well plates can be centrifuged at a maximum of 1,790 x g with the RMP-206 rotor. In the event of breakage, all fragments will be safely retained...
Open the catalog to page 2
Useful functions for easy operation Three available memory settings, with one key save and recall operation The memory function makes repetitive operations using the same speed and time values easy. Numerous detectors ensure safe, reliable operation. If trouble is detected, operation stops immediately. Buzzer sounds at the end of operation Five different buzzer sounds allow easy discrimination when any centrifuge operation ends among more than Complies with GMP requirements The tachometer port on the top of the lid enables easy checking of actual rotor speed, and complies with GMP Actual...
Open the catalog to page 3
Table-top refrigerated centrifuge with a small footprint Two Types of Swinging Bucket 4,000rpm Rotor • Multiple swinging bucket rotors for 24 x 15mL tubes • Plate rotor for 2 x PCR plates / 6 x Micro-plates / 2 x Deep-well plates The small footprint Model 2800 can centrifuge 24 x 15mL tubes at 4,000rpm. Compact size, only 37cm (W) x 64cm (D) x 37cm (H), and refrigerated Rotor for PCR plates / Micro-plates / Deep-well plates can be used. 2 x PCR plates, 6 x Micro-plates or 2 x Deep-well plates can be centrifuged at a maximum of 1,790 x g with the RMP-206 rotor. Sample temperature is...
Open the catalog to page 4
Useful functions for easy operation Three available memory settings, with one key save and recall operation. Numerous detectors ensure safe, reliable operation. If trouble is detected, operation stops immediately. Five different buzzer sounds allow easy discrimination when any centrifuge operation ends among more than Complies with GMP requirements Actual rotor speed can be measured using the Actual rotor radius can be set, enabling accurate display Pre-cooling allows rotors to reach low temperature before experiments. Memory flashing enables easy spin down. (Patented)...
Open the catalog to page 5
Rotor, Bucket, Tube Rack Table for Model 2420/2800 Tube Flow Cytometer Nominal Capacity Tube size (mm) diam. x length Swinging bucket rotor Buckets and adaptors are optional. NEW Tube Rack, Adaptor Code No. The number of times allowed for autoclaving are limited. Please refer an instruction manual. Nominal Capacity Tube size (mm) diam. x length Swinging bucket rotor Maximum Speed rpm Maximum RCF x g Buckets and adaptors are optional. Tube Rack, Adaptor Code No. The number of times allowed for autoclaving are limited. Please refer an instruction manual. Equipped with sealing caps (patent...
Open the catalog to page 6
Equipped with sealing caps (patent pending) To show the RCF exactly, input the rotation radius. At the factory, the rotation radius is pre-set at 14.6cm. The above Maximum RCF is the calculated value at the maximum speed at each rotation radius. Tube support can be produced for special tube sizes. Contact our distributor. 5-7mL Blood collecting tubes made by SEKISUI (Insepack II), Termo (Venoject II), Nipro (Neotube) or Beckton Dickinson (Vacutenar) can be used. 7-10mL Blood collecting tubes made by SEKISUI (Insepack II), Termo (Venoject II), Nipro (Neotube) or Beckton Dickinson (Vacutenar)...
Open the catalog to page 7
Specifications Model 2420 Maximum Speed¡ 4,000 rpm Maximum RCF¡ 2,610 xg Maximum Capacity¡ 360 mL Control system¡ Microprocessor control (brushless motor) Speed, RCF(g), Time, Acceleration and Deceleration, 3 memory banks Alarm display¡ Lid open, Imbalance, Over speed, Detected electrical abnormality in motor, inverter, lid interlock and speed sensor Acceleration/Deceleration¡ Two selectable rates: Rapid, Slow, 4ways of setting Speed setting¡ From 200 to 4,000 rpm, 100 rpm increments Speed indication¡ Digital display, from 0 to 4,300 rpm, 100 rpm increments RCF setting¡ From 100...
Open the catalog to page 8All KUBOTA catalogs and technical brochures
-
Model 9942
8 Pages
-
Model 5500
4 Pages
-
Model 3520
4 Pages
-
5922
8 Pages
-
5911
8 Pages
-
8420
4 Pages
-
4000, 4200
8 Pages