4000, 4200
1 / 8Pages

Catalog excerpts

4000, 4200 - 1

General-purpose model High Speed model

Open the catalog to page ١
4000, 4200 - 2

General-purpose model The table-top centrifuge can centrifuge 68 x 15 mL tubes, 16 x 50 mL Conical tubes, or 4 x 250 mL bottles. The 4000/4200 models share these features:- ■ Simple design and operability ■ The chamber opening is 27.5 cm high and 38 cm wide (full-open type). Samples can be easily An automatic interlock lid is employed. (Patent pending) The lid automatically locks when closed and automatically opens when rotation stops. ■ The operating status lamp on top of the lid can be seen at a distance. Seven lamp colors are user-selectable. (Patented) ■ Five different buzzer sounds...

Open the catalog to page ٢
4000, 4200 - 3

High speed model Maximum Speed — 16,000rpm Maximum RCF — 23,470xg The Microtiter rotor (accommodating 24 x 2 mL tubes) is rated for 16,000 rpm/23,470 x g. A high-speed microtiter rotor can also be used. The 4000/4200 models share these features: A tool-less rotor is employed, for easy rotor Rotor changing. (Excluding the RA-2724M.) No tools are required when setting or changing applicable rotors. The Microtiter rotor RA-2724M can be operated at 16,000 rpm. (Model 4200.) A tube rack (Code No.055-0880, 055-1140) has been developed to accommodate blood collecting tubes of various sizes (such...

Open the catalog to page ٣
4000, 4200 - 4

Rotor, Bucket, Tube Rack Table for Model 4000/4200 Flow Cytometer Swinging bucket rotor Choose either bucket. The maximum speed and maximum RCF of ST-722M indicated on the left in red. The maximum speed and maximum RCF of ST-2504MS indicated on the right in blue. Swinging bucket rotor Choose either bucket. The maximum speed and maximum RCF of ST-722M indicated on the left in red. The maximum speed and maximum RCF of ST-2504MS indicated on the right in blue.

Open the catalog to page ٤
4000, 4200 - 5

Flow Cytometer This convenient tube rack can accommodate blood collecting tubes of various sizes (such as 5 mL, 7 mL, 10 mL), as well as 15 mL glass tubes.

Open the catalog to page ٥
4000, 4200 - 6

The maximum speed and maximum RCF of ST-504M indicated in the brackets ( ). Equipped with sealing cap (patent pending) Maximum 16 tubes of 5-7 mL blood collecting tubes made by Termo (Venoject II) can be used. 5-7mL blood collecting tubes made by SEKISUI (Insepack II), Termo (Venoject II), Nipro (Neotube), Beckton Dickinson (Vacutenar) can be used. Tube for flow cytometry can also be used. Vacutenar 8 mL blood collecting tubes for CPT cell separation (nominal 16 x 125) made by Beckton Dickinson can be used. 5-10mL blood collecting tubes made by SEKISUI (Insepack II), Termo (Venoject II),...

Open the catalog to page ٦
4000, 4200 - 7

Micro-plate rotor Micro rotor

Open the catalog to page ٧
4000, 4200 - 8

Specifications Model 4000/4200 Maximum Speed Maximum RCF Maximum Capacity Drive system Control system 6,000rpm (4000) / 16,000pm (4200) 5,350xg (4000) / 23,470xg (4200) 1,020mL Direct drive (Direct connection with brushless motor) Micro-processor control (Brushless motor) Speed, RCF, Time, Acceleration & Deceleration, 5 channel memories Acceleration : 2 level selections, Rapid and Slow Deceleration : 3 level selections, Rapid, Slow and Natural deceleration Lid open, Imbalance, Over speed, Rotor mounting abnormally, Function for detecting an occurrence of electrical abnormally in motor,...

Open the catalog to page ٨

All KUBOTA catalogs and technical brochures

  1. Model 9942

    8 Pages

  2. Model 5500

    4 Pages

  3. Model 3520

    4 Pages

  4. 5922

    8 Pages

  5. 5911

    8 Pages

  6. 8420

    4 Pages

  7. 2420, 2800

    8 Pages