5922
1 / 8Pages

Catalog excerpts

5922 - 2

RCF of 21,040 x g, Tool-less rotor, and 12 types of rotors available. Employs a tool-less rotor that is easy to set. In addition, the rotors now in use can be used commonly. (See the Rotor list.) Maximum speed 15,000 rpm Maximum RCF 21,040 x g A versatile refrigerated centrifuge Microtiter plates, deep-well plates, mediumcapacity fixed-angle rotors, multi-tube-loading swinging bucket rotors available Aims at safety in design and conforms to the international safety standard IEC 61010-2-020. Short acceleration/deceleration time at both high and low speeds 10 sec/10 sec for 18 x 2mL tubes...

Open the catalog to page 2
5922 - 3

Features ■ The tool-less rotors can be set or changed without using a tool. (except when RA-410M3 rotor is used) (See the Tool-less Rotor column of the Rotor list.) ■ Various types of rotors are available and one unit can accommodate them in a versatile manner. • Three types of micro rotors Maximum speed 15,000rpm, maximum RCF 20,630xg (AT-2018M / 2724M) Bio sealed rotor which can spin at 14,000rpm / 21,040xg (AT-2730M) • The medium-capacity fixed-angle rotor for 8 x 50 mL Conical tubes. • Two types of plate rotors. A high-speed plate rotor can do ethanol precipitation. • Anti-biohazard...

Open the catalog to page 3
5922 - 4

Rotor, Bucket, Tube Rack Table for Model 5922 Tube Flow Cytometer 36 x 1.5/2mL Nominal Capacity Swinging bucket rotor Tube size (mm) diam. x length 68 x 5〜7mL narrow blood collecting tube 24 x 8mL CPT cell preparation tube Bucket Code No. Adaptor Code No. 053-5840 055-0260 Tube Rack, Adaptor Code No. Tube Rack, Adaptor Code No. Bucket Code No. 053-0020 Choose either bucket. Sealing caps and O-rings Code No.055-0964 Buckets and sealing caps are optional. Tube Rack, Adaptor Code No. Sealing caps and O-rings Code No.055-0964 Buckets are equipped with rotor. Sealing caps are optional. Tube...

Open the catalog to page 4
5922 - 5

Flow Cytometer 68 x 10mL blood collecting 28 x 5〜10mL blood collecting 48 x 5〜10mL blood collecting 48 x 5〜10mL blood collecting 16 x 15mL Conical tube tube/15mL (glass) tube/15mL (glass) tube/15mL (glass) tube/15mL (glass) 15〜17.2×52〜110 This convenient tube rack can accommodate blood collecting tubes of various sizes (such as 5 mL, 7 mL, 10 mL), as well as 15 mL glass tubes. 1 5-7mL blood collecting tubes made by SEKISUI (Insepack II), Termo (Venoject II), Nipro (Neotube), Beckton Dickinson (Vacutainer) can be used. Tube for flow cytometry can also be used. 2 Vacutainer 8 mL blood...

Open the catalog to page 5
5922 - 6

Rotor, Bucket, Tube Rack Table for Model 5922 Micro The number of times allowed for autoclaving are limited. Please refer an instruction manual. Blood collecting tubes, glass tubes Flow Cytometer Nominal Capacity 48 x 1.5/2mL Swinging bucket rotor ST-480M 16 x 5〜10mL blood collecting tube 4 x 10mL blood collecting 8 x 10mL blood collecting 32 x 10mL blood collecting tube/15mL (glass) tube/15mL (glass) tube/15mL (glass) Tube size (mm) diam. x length Rubber cushion Code No. Rubber cushion Code No. Choose optional buckets, adaptors and cushions. The maximum speed and maximum RCF of ST-504M...

Open the catalog to page 6
5922 - 7

Micro-plate rotor Test plates Tube size (mm) diam. x length 2 x PCR plate 8 x micro-plate 4 x deepwell-plate 2 x PCR plate 12 x micro-plate 4 x deepwell-plate 1 Verify plate strength before centrifuging. Plates in lower position may fracture. 2 Optional tray is available. Micro-plate rotor The number of times allowed for autoclaving are limited. Please refer an instruction manual. Tube size (mm) diam. x length Acceleration and deceleration is in 10 seconds. 30 x 1.5/2mL 9.5〜11×36〜42 This is a bioshield rotor. Samples will not leak out from the rotor even if the 0.2mL PCR tube may not use at...

Open the catalog to page 7
5922 - 8

Specifications           Maximum Speed¡ 15,000 rpm Maximum RCF¡ 21,040 xg Maximum Capacity¡ 2,000 mL Control system¡ Micro-processor control (Brushless motor) Speed, RCF, Time, Acceleration & Deceleration, 5 channel memories Alarm display¡ Lid open, Imbalance, Over speed, Function for detecting an occurrence of electrical abnormality in motor, inverter, lid interlock and speed sensor. Acceleration / Deceleration¡ Three-level selectors; Rapid, Slow and Super Slow Speed setting¡ From 200 to 15,000 rpm, 10 rpm increments Speed indication¡ Digital display, From 0 to 15,500 rpm, 10 rpm...

Open the catalog to page 8