K Refrilab Elite series
1 / 6Pages

Catalog excerpts

K Refrilab Elite series - 1

K Refrilab Elite series K Freezelab Elite / Super series

Open the catalog to page 1
K Refrilab Elite series - 2

K Refrilab Elite series K Freezelab Elite / Super series

Open the catalog to page 2
K Refrilab Elite series - 3

K Refrilab Elite series vertical refrigerators 0 °C +10 °C • The KRE line creates a new standard in positive-T refrigeration, completing the historic FREEZELAB offering. • This series is characterized by being an innovative solution for the conservation of pharmaceutical and diagnostic products and biological material in general. vertical refrigerators Model External measurements (WXDXH) Internal measurements (WXDXH) Operation temperature Average power consumed in Kw Regulation range: from 0 °C to +10 °C Power supply: Volt 220/50/1 X = internal/external - structure in AISI 304 stainless...

Open the catalog to page 3
K Refrilab Elite series - 4

K Refrilab Elite series K Freezelab Elite / Super series KW’s Frig line is distributed by KW and has two possible control systems, known by the initials SLC (Silver Line Control) and NIA (New Ice Age). Keyboard and display 4-key keyboard with menu structure and LED display, 2+1/2 digits with automatic digital point (between -19.9 °C and +19.9 °C), marked; perfectly visible with natural or artificial light from any angle. The new control GLC (Golden Line Control) will take the place of SLC (see GLC release) • SLC (Silver Line Control) system Electronic digital thermoregulator specific for...

Open the catalog to page 4
K Refrilab Elite series - 5

K Refrilab Elite series K Freezelab Elite / Super series Visual alarms: SENSOR ALARMS In case of temperature alarm breakdown or failure. TEMPERATURE ALARM If, for any reason, the temperature starts increasing or decreasing until it falls outside the allowed range (configured with respect to the defined set point), the internal timer is activated (configurable alarm delay, 30 minutes by default but the value can be modified upon customer request); after this period the TEMPERATURE ALARM activates both visual and sound (BUZZER) alerts, and at the same time activates the remote alarm contact...

Open the catalog to page 5
K Refrilab Elite series - 6

= min./max temperature alarm Contacts: Managing Director: management@kwkw.it Technical Production Manager: technician@kwkw.it Sales Manager: sales@kwkw.it Tender Commercial Office: commerciale@kwkw.it International Sales Manager: expdpt@kwkw.it Technical Support & Spare Parts: assistenza@kwkw.it Service line: service@kwkw.it Delivery Office: delivery@kwkw.it Administration: administration@kwkw.it = DATA LOGGER function = energy failure alarm = Alarm broken down probe = Open door alarm = Disaster Ricovery / Safety Control = Temperature recorder KW Apparecchi Scientici, taking into...

Open the catalog to page 6

All KW Apparecchi Scientifici catalogs and technical brochures

  1. W-WR series

    6 Pages

  2. BloodLine

    74 Pages

  3. AC series

    8 Pages

  4. WRC series

    3 Pages

  5. NIA series

    10 Pages

  6. SLC series

    6 Pages

  7. IFM series

    6 Pages

  8. KFT series

    4 Pages

  9. K series

    20 Pages

  10. KLAB series

    34 Pages

  11. KRFDC series

    4 Pages

  12. KRFDS series

    4 Pages

  13. KRFDE series

    6 Pages

  14. KFCS series

    4 Pages

  15. KFCE series

    6 Pages

  16. KFDC series

    4 Pages

  17. KFDS series

    4 Pages

  18. KFDE series

    6 Pages

  19. ServiceLine

    18 Pages

  20. WS series

    4 Pages

  21. WI series

    4 Pages