K130A_K130C_series-3

K.130 A - K.130 C series freezers at -125 °C STRUCTURE: The internal casing is in AISI 304 stainless steel (or AISI 316 upon request) with rounded angles for easy cleaning; the external cabinet is a plasticised, zinc-plated steel sheet; the insulation is in polyurethane resin, foamed on site, with a density of about 40 Kg/m3 and a noticeable average thickness: 190 mm. CFC-, HCFC-free; the door is placed on the upper part, mounted on self-balancing hinges; internal counter doors (in plastic-coated foamed polyurethane resin) sliding on a special track; it has a triple silicone rubber seal, welded...

 Open the catalog to page 3
K130A_K130C_series-4

K.130 A - K.130 C series freezers at -125 °C Self-diagnosis test: upon boot up, the freezer’s LEDs and buzzer are activated for about 1”. User Menu access protected by password. Password-protected Setup access menu for service operations. Cooling Startup/Shutdown The startup and shutdown of the cooling cycle requires password-protected manoeuvres: The cycle starts from a standby status (lower display showing OFF). First the “START” key is pressed, then the display shows a password request; if correctly inserted, the cooling cycle will start; otherwise the display will show OFF again. The same...

 Open the catalog to page 4
K130A_K130C_series-5

PRESS ALARM DOOR OPEN POWER FAIL TEMP ALARM ACCESSORIES Upon request, each system can be furnished with: • Electronic video graphical recorder with RTD input Pt 100 Ω, V230/1/50 • Additional sensors for T, RTD Pt 100, to connect to an external system for the acquisition and recording of T values, such as KW SPY® or similar. • Additional RTD Pt 100 sensor complete with 4-20 mA converter mounted on a DIN bar to connect to an external recording system. • Internal-external ø 25 mm. connection holes with external rubber stopper. • Emergency LN2 system (complete with connection, flexible hose and security...

 Open the catalog to page 5
K130A_K130C_series-6

= min./max temperature alarm Contacts: Managing Director: [email protected] Technical Production Manager: [email protected] Sales Manager: [email protected] Tender Commercial Office: [email protected] International Sales Manager: [email protected] Technical Support & Spare Parts: [email protected] Service line: [email protected] Delivery Office: [email protected] Administration: [email protected] = DATA LOGGER function = energy failure alarm = Alarm broken down probe = Open door alarm = Disaster Ricovery / Safety Control = Temperature recorder KW Apparecchi Scientici, taking into consideration...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.