KFDE series
1 /6Pages

KFDE series

KFDE series
1 /6Pages

Catalog excerpts

KFDE series-1

KFDE series vertical freezers at -20 °C -30 °C Elite line

 Open the catalog to page 1
KFDE series-2

KFDE series vertical freezers at -20 °C -30 °C Elite line KFDE 520 KFDE 350 KFDE 080

 Open the catalog to page 2
KFDE series-3

KFDE series vertical freezers at -20 °C -30 °C Elite line KW offers a new featured series of vertical freezers for laboratory and biological tasks, with small and medium volumes. The structure has removable drawers, for better use of the internal volume and lower power consumption, in addition to adequate insulation thickness. The fully sealed execution of the refrigerating circuit and the use of airtight compressors make these freezers a silent and reliable option, even in critical environmental conditions. The materials and the fluids being used are all natural and environmentally friendly,...

 Open the catalog to page 3
KFDE series-4

KFDE series vertical freezers at -20 °C -30 °C Elite line KW distributes the KFDE line with two possible control systems, known by the initials SLC (Silver Line Control) and NIA (New Ice Age). The new control GLC (Golden Line Control) will take the place of SLC (see GLC release) Keyboard and display 4–key keyboard with menu structure and LED display, 2+1/2 digits with automatic digital point (between -19.9 °C and +19.9 °C), marked; perfectly visible with natural or artificial light from any angle. • SLC (Silver Line Control) system Electronic digital thermoregulator specific for industrial and...

 Open the catalog to page 4
KFDE series-5

KFDE series vertical freezers at -20 °C -30 °C Elite line Visual alarms: SENSOR ALARMS In case of temperature alarm breakdown or failure. TEMPERATURE ALARM If, for any reason, the temperature starts increasing or decreasing until it falls outside the allowed range (configured with respect to the defined set point), the internal timer is activated (configurable alarm delay, 30 minutes by default but the value can be modified upon customer request); after this period the TEMPERATURE ALARM activates both visual and sound (BUZZER) alerts, and at the same time activates the remote alarm contact to...

 Open the catalog to page 5
KFDE series-6

= min./max temperature alarm Contacts: Managing Director: [email protected] Technical Production Manager: [email protected] Sales Manager: [email protected] Tender Commercial Office: [email protected] International Sales Manager: [email protected] Technical Support & Spare Parts: [email protected] Service line: [email protected] Delivery Office: [email protected] Administration: [email protected] = DATA LOGGER function = energy failure alarm = Alarm broken down probe = Open door alarm = Disaster Ricovery / Safety Control = Temperature recorder KW Apparecchi Scientici, taking into consideration...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.