KW Frig series horizontal and vertical freezers at -30 °C -40 °C
Open the catalog to page 1KW Frig series horizontal and vertical freezers at -30 °C -40 °C
Open the catalog to page 2serie KW Frig congelatori orizzontali e verticali -30°C -40°C KW FRIG® is a series of horizontal and vertical freezers for preservation up to -30 °C / -40 °C, ideal, given its capacity, for use in scientific and hospital laboratories. The KWFRIG® series is characterized by safety and practicality: - in the horizontal models: reinforced hinges with compensation to balance the door weight, facilitating both opening and closing; internal structure in light alloys with protection against the danger of scratching and breaking and smoothed internal angles for easier cleaning; - in the vertical models:...
Open the catalog to page 3KW Frig series horizontal and vertical freezers at -30 °C -40 °C KW’s Frig line is distributed by KW and has two possible control systems, known by the initials SLC (Silver Line Control) and NIA (New Ice Age). The new control GLC (Golden Line Control) will take the place of SLC (see GLC release) Keyboard and display 4-key keyboard with menu structure and LED display, 2+1/2 digits with automatic digital point (between -19.9 °C and +19.9 °C), marked; perfectly visible with natural or artificial light from any angle. • SLC (Silver Line Control) system Electronic digital thermoregulator specific...
Open the catalog to page 4serie KW Frig congelatori orizzontali e verticali -30°C -40°C Visual alarms: SENSOR ALARMS In case of temperature alarm breakdown or failure. TEMPERATURE ALARM If, for any reason, the temperature starts increasing or decreasing until it falls outside the allowed range (configured with respect to the defined set point), the internal timer is activated (configurable alarm delay, 30 minutes by default but the value can be modified upon customer request); after this period the TEMPERATURE ALARM activates both visual and sound (BUZZER) alerts, and at the same time activates the remote alarm contact...
Open the catalog to page 5= min./max temperature alarm Contacts: Managing Director: [email protected] Technical Production Manager: [email protected] Sales Manager: [email protected] Tender Commercial Office: [email protected] International Sales Manager: [email protected] Technical Support & Spare Parts: [email protected] Service line: [email protected] Delivery Office: [email protected] Administration: [email protected] = DATA LOGGER function = energy failure alarm = Alarm broken down probe = Open door alarm = Disaster Ricovery / Safety Control = Temperature recorder KW Apparecchi Scientici, taking into consideration...
Open the catalog to page 66 Pages
6 Pages
6 Pages
6 Pages
74 Pages
4 Pages
4 Pages
8 Pages
6 Pages
4 Pages
4 Pages
6 Pages
6 Pages
3 Pages
6 Pages
10 Pages
6 Pages
6 Pages
4 Pages
20 Pages
10 Pages
8 Pages
34 Pages
4 Pages
4 Pages
6 Pages
4 Pages
6 Pages
4 Pages
4 Pages
6 Pages
4 Pages
20 Pages
18 Pages
18 Pages
4 Pages
4 Pages
6 Pages