PH-8 Lung Cancer Screening CT Phantom LSCT0001
2Pages

{{requestButtons}}

Catalog excerpts

PH-8 Lung Cancer Screening CT Phantom LSCT0001 - 1

Lung Cancer Screening CT Phantom LSCT0001 is a CT phantom developed to facilitate optimizing the radiation dose and other scanning conditions for Lung Cancer Screening CT examination with Helical CT or MDCT, which is aiming at early detection of lung cancers. As the screening is usually done on healthy people, the necessity of minimizing the exposure while maximizing the image quality is considered to be particularly high. The phantom is designed to set conditions for detection of small early lung cancers such as GGA, which are difficult to be found by plain X-ray. Anthropologic structure of the phantom provides life-like images allowing operators visual evaluation, while quantitative evaluation on radiation dose and density curve of the image can be done stimulatory with a single scanning. Unique phantom dedicated for optimizing lung cancer CT screening conditions, as well as setting the standard conditions between multiple equipments or facilities for mass screening. Original human tissue substitute material creates life-like artifact under CT scanning Simulated GGA type tumors are embedded on three main sections of both lungs. Dose meter holder on the central axis of the phantom allows housing a pencil type chamber dose meter. 8-step cylindrical linearity phantom to control density curve as a scale can be attached to the chest phantom base. LSCT 0001 with dose meter Set Includes: Phantom includes: 1 Chest Phantom: life size torso with arm up position Internal structures: Bones Simulated tumors on sections of three lung area Apical portion of the lungs Bifurcation of the trachea Base of lungs Dose meter hole (13 mm dia., on the central axis of the phantom) Sizes: Chest Phantom Measurement around the chest 93 cm Height 45 cm Weight approx.18 kg Linearity phantom Diameter 200mm Height 100 mm 1 8-step linearity phantom 8 steps of 30mm dia. density samples are embedded 1 adjustment base www.kyotokagaku.com rw-kyoto@kyotokagaku.co.jp Head Office: 15 Kitanekoya-cho, Fushimi-ku, Kyoto, 612-8388, JAPAN Tel: +81-75-605-2510 Fax: +81-75-605-2519 USA Office: 3109 Lomita Boulevard, Torrance, CA 90505-5108, USA Tel: 1- 310 - 325 - 8860 Fax: 1- 310-325-8867

Open the catalog to page 1
PH-8 Lung Cancer Screening CT Phantom LSCT0001 - 2

Lung Cancer Screening CT Phantom LSCT 0001 Materials and CT features CT images Chest phantom walls and mediastinum Human soft tissue substitute material Bones Human bone substitute material (epoxy base synthetic bone) Lung background Polysterol foam HU# -900 dose meter hole Apical portion Apical portion Simulated tumors HU contrast with the lung back ground Tumors in the right lung Urethane resin Tumors in the left lung Urethane resin Linearity Phantom Linearity phantom background Urethane resin HU# 60 Linearity phantom targets Materials Polyacetal resin www.kyotokagaku.com...

Open the catalog to page 2

All Kyoto Kagaku catalogs and technical brochures