1. Catalogs
  2. Kyoto Kagaku
  3. Radiology Phantoms

Radiology Phantoms

Radiology Phantoms
1 / 52 PagesView full catalog

Radiology Phantoms

Product catalog summary
Overview: The document is a comprehensive product catalog from Kyoto Kagaku, detailing a range of radiology phantoms used for educational and training purposes in medical imaging. These phantoms simulate human anatomy to optimize scanning parameters and improve diagnostic skills.
Product Listings: The catalog includes various phantoms such as newborn, pediatric, and adult whole body phantoms, each tailored for specific training applications like CT, X-ray, and dosimetry. Each product entry provides features, anatomical details, materials, and specifications.
Specifications: Detailed specifications are provided for each phantom, including dimensions, weight, and materials. For instance, the newborn whole body phantom is made of urethane-based resin and epoxy resin, with specific densities for soft tissue and synthetic bone.
Applications: Phantoms are used for basic patient positioning, radiology absorption studies, and training in detecting bone fractures and signs of child maltreatment. They are also used in CT and X-ray imaging for training scenarios, including rough handling, and for studying the effects of patient size on radiation dose and image quality.
Optional Parts and Accessories: Some phantoms come with optional storage cases and additional components to enhance their utility in training scenarios. Optional parts include body plates for different BMI simulations and components for radioisotope studies.
Educational Value: The catalog emphasizes the educational benefits of using these phantoms, such as improving skills in radiographic interpretation and understanding the signs of child abuse through specific fracture patterns.
Specific Models: The document describes several specific models, including the "PBU-90 RUGGED" for whole-body imaging, the "LUNGMAN" chest phantom for lung cancer screening, and the PET/SPECT Thorax Phantom for nuclear medicine studies.
Research and References: The document references studies and publications that have utilized these phantoms for research in imaging techniques and radiology.
CT Torso Phantom: This section describes a one-piece anthropomorphic torso phantom designed for CT scanning, including helical scans. It includes synthetic bones and soft tissues made from urethane and epoxy resins.
CT Head Phantom: The head phantom is available in three variations for CT, angiography, and multi-energy CT, featuring contrast-enhanced cerebral arteries for training in CT scanning and angiography.
Dental Radiography Head Phantom: Designed for dental radiography training, this phantom features open and closed mouth options and detachable jaws and tongue.
CT Abdomen Phantom: Used for studying image fusion between CT and ultrasound, it includes organs and vessels made from multi-energy compatible materials.
Stomach Phantoms: Two types of stomach phantoms are described for double contrast gastrography, simulating real stomach lesions.
CT Prostate and Knee Ligament Phantoms: Used for therapy planning and training in CT scanning, these phantoms include organs with close-to-human Hounsfield Units (HU).
CT Colonography Phantom: Designed for virtual colonography, it includes cylindrical colon units with targets representing polyps.
Lumbar Spine Fluoroscopy Training Phantom: Used for training in vertebroplasty and fluoroscopy-guided procedures, it includes replaceable training blocks.
Multi-Energy CT Phantoms: An overview of Kyoto Kagaku's new lineup of multi-energy CT phantoms, supporting advanced medical imaging techniques and research.
Contrast Detail Phantom: Used for image evaluation in plain X-ray, these phantoms assess image quality and contrast detail.
Dynamic Thorax Phantom: Simulates the motion of the diaphragm, heart, and lungs for respiratory gating and tumor tracking in radiotherapy.
Tough Phantom Series: Designed for radiotherapy, these phantoms mimic human tissues and bones, suitable for dosimetry and therapy planning.
MRI Quality Assurance Phantom: Used for evaluating MRI parameters such as slice thickness and spatial resolution, compliant with NEMA standards.
PET/SPECT Phantoms: Simulate the absorption and scatter characteristics of human tissues in nuclear medicine, including brain and thyroid phantoms.
Applications: Phantoms are used in dosimetry, quality assurance, clinical research, and therapy planning across different imaging modalities.
See more

Catalog excerpts

Radiology Phantoms-1

KYOTO, TOKYO, NAGOYA AND SENDAI, JAPAN LOS ANGELES, USA HONG KONG, CHINA FRANKFURT, GERMANY DISTRIBUTORS ALL OVER THE WORLD KYOTO KAGAKU PRODUCT CATALOG

 Open the catalog to page 1
Radiology Phantoms-2

Icon Legend Hole for dosimeter Storage case

 Open the catalog to page 2
Radiology Phantoms-3

RADIOLOGY PHANTOMS CONTENTS Feature Article Kyoto Kagaku Anthropomorphic Phantoms P.5 Newborn Whole Body Phantom "PBU-80" P.8 CT Whole Body Phantom "PBU-60" Newborn Whole Body Phantom PH-2E Pediatric Whole Body Phantom "PBU-70" PH-2 Fractured Hand/Forearm Phantom PH-2/2B Multipurpose Chest Phantom N1 "LUNGMAN" PH-63 Bone Fracture Pediatric Phantom "PBU-70B" PH-60 Tough Whole Body Phantom "PBU-90 RUGGED" Subsolid Nodules Phantom Pediatric Chest Phantom Angiographic CT Head Phantom ACS (for CT/Angio/MECT) Lung Cancer Screening CT Phantom LSCT001 PET/ SPECT Thorax Phantom PH-4 Sectional Phantom...

 Open the catalog to page 3
Radiology Phantoms-4

Feature Article Kyoto Kagaku Multi-Energy CT Phantoms Multi Energy CT Quality Assurance Phantom Bone Scintigraphy Quality Assurance Phantom PH-59 Dynamic Heart and Lung Phantom Digital Mammographic Phantom NCCE (fall) P.39 Multi Slice CT Phantom MHT P.37 Ladder Phantom Water Body Phantom WAC Dynamic Thorax Phantom PH-38 Dynamic Cardiac CT Phantom MD-CT CT-DI Phantom (Head and Body Phantom) P.36 Contrast Detail Phantom P.41 Tough Phantom Series Therapy Body Phantom THRA-1 Pediatric Therapy Body Phantom THRA-2 PH-31/ 32B MRI Quality Assurance Phantom MHR/JMRⅡ PH-64 PET/SPECT Brain Phantom PH-65...

 Open the catalog to page 4
Radiology Phantoms-5

ANTHROPOMORPHIC PHANTOMS Kyoto Kagaku Anthropomorphic Phantoms Our Anthropomorphic phantoms provide life like images and attenuation. Ideal for educational training applications and help to determine and evaluate optimal scanning parameters. We provide a variety of anthropomorphic phantoms to meet your requirements that suits you best NEWBORN Standard Bone fracture Meconium aspiration syndrome* *Option CT Dosimetry The above matrix chart indicates the most recommended application/modality for use of each phantom and not necessarily means the phantom should exclusively be used with marked modalities....

 Open the catalog to page 5
Radiology Phantoms-6

PH-50B 41912-100 Newborn Whole Body Phantom "PBU-80" A brand-new neonate for CT has come into the world ANTHROPOMORPHIC PHANTOMS CT and plain X-ray Dosimetry Autopsy imaging Positioning: upright AP / supine AP / upright lateral / supine lateral Limbs rotate 360 degrees at shoulders and hip joints Left hand is clenched and right hand is open Kyoto Kagaku original human tissue substitute A hole for an ion chamber HU of average newborn (HU 30) ANATOMY skull / spine/ clavicles / scapulae / ribs / humerus / radius / ulnae / bones of hands / femora / tibiae / fibula / bones of foot / pelvis / lungs...

 Open the catalog to page 6
Radiology Phantoms-7

ANTHROPOMORPHIC PHANTOMS PH-2C 41350-300 Pediatric Whole Body Phantom "PBU-70" This phantom representing a five-year-old child is easy to position, and provides complete bone images for every joint APPLICATIONS Plain X-ray CT Basic patient positioning | Radiology absorption and HU number approximate to human body | Main joints have close-to human articulation | Phantom can be disassembled into 10 individual parts Bony Structure Internal organs skull / spine/ clavicles / scapulae / ribs / sternum / coxal lung with pulmonary vessels / trachea (up to primary bronchi) bones / humerus / antebrachial...

 Open the catalog to page 7
Radiology Phantoms-8

PH-2D 41350-500 Bone Fracture Pediatric Phantom "PBU-70B" Improve skills in detecting bone fractures in children and cultivate awareness of child maltreatment. ANTHROPOMORPHIC PHANTOMS Plain X-ray CT Basic patient positioning Radiographic interpretation APPLICATIONS | Training in pediatric radiography can be enriched with clear and subtle bone fractures | Typical fractures resulting from child abuse are also included | Radiology absorption and HU number approximate to human body | Main joints have close-to human articulation | Phantom can be disassembled into 10 individual parts CONCEPT and ANATOMY...

 Open the catalog to page 8
Radiology Phantoms-9

ANTHROPOMORPHIC PHANTOMS PH-2B 41350-200 CT Whole Body Phantom "PBU-60" A unique, life size whole body phantom for CT provides a variety of educational application as well as visual evaluation in finding out optimal scanning conditions iThe phantom includes full internal organs with close-to-human HU for each. i Radiology absorption and HU approximate to human body | Main joints have close-to human articulation i Phantom can be disassembled into 10 individual parts CT Plain X-ray Basic patient positioning ANATOMY Full internal organs Bony structure Synthetic skull Coxal bones Cervical vertebrae...

 Open the catalog to page 9
Radiology Phantoms-10

ANTHROPOMORPHIC PHANTOMS FEATURES APPLICATIONS | Pathological findings added to detailed anatomy of PBU-60 | Radiology absorption and HU number approximate to human body | Main joints have close-to human articulation | Phantom can be disassembled into 10 individual parts T Plain X-ray asic patient positioning ANATOMY and PATHOLOGY Cases Full internal organs Bony structure Synthetic skull Cervical vertebrae Vertebrae Clavicles Ribs Sternum Scapula Coxal bones Femurs Internal organs Internal organs DESCRIPTIONS SET INCLUDES 1 whole body phantom 1 set of sample CT/X-ray data (DVD) 1 head supporter...

 Open the catalog to page 10
Radiology Phantoms-11

ANTHROPOMORPHIC PHANTOMS Whole Body Phantom "PBU-50" An essential asset for every radiography program | Radiology absorption and HU number approximate to human body. | Main joints have close-to human articulation | Phantom can be disassembled into 10 individual parts | Plain X-ray | Basic patient positioning | Basic CT ANATO MY skull / spine / clavicles / scapulae / ribs / sternum / coxal bones / lungs with pulmonary vessels / trachea (up to primary bronchi) / heart / liver with portal and hepatic veins / kidneys / humerus / antebrachial bone / bones of hand / femur / patella / lower leg bone...

 Open the catalog to page 11
Radiology Phantoms-12

Tough Whole Body Phantom "PBU-90 RUGGED" New phantom material is designed for rough handling, improved durability and less maintenance Durability testing F E AT URES | Radiology absorption and HU number approximate to human body. | Main joints have close-to human articulation | Phantom can be disassembled into 10 individual parts | Plain X-ray | Basic patient positioning | Basic CT PBU-90 allows training scenarios that involve rough handling. Details of the bones in the hands and the feet are simplified compared to those of PBU-50/60 for increased durability. ANATO MY skull / spine / clavicles...

 Open the catalog to page 12

All Kyoto Kagaku catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.