Unigamma M
4Pages

{{requestButtons}}

Catalog excerpts

Unigamma M - 1

l’acn - l’accessorio nucleare S.r.l via 25 Aprile 9/13 - 20023 CERRO MAGGIORE MI (ITALY) tel. +39 (0)331 420303 - fax +39 (0)331 420153 website: www.acn.it - email: acn@acn.it Unigamma M MULTIDETECTOR DEXA FAN BEAM BONE DENSITOMETER Unigamma M is the all-purpose dexa bone mineral densitometer produced by l’acn. The small fan beam technology and the scalable architecture allow an optimal compromise between productivity and image quality, no matter how large is yor patients throughp

Open the catalog to page 1
Unigamma M - 2

Unigamma M Osteoporosis is an ever growing problem affecting millions of women and men worldwide. The healthcare costs associated with osteoporosis are staggering, and the effect on your patient’s quality of life can be devastating. But fortunately, osteoporosis is detectable and treatable. Testing is safe and non invasive so you can test for osteoporosis in your office. l’acn Over 25 years now l’acn from the very North of Italy has designed and supplied bone densitometry systems to customers worldwide. R&D efforts focus on providing efficient clinical solutions in a competitive...

Open the catalog to page 2
Unigamma M - 3

Unigamma M Multi Pencil Beams in Fan Beam geometry. Finely collimated pencil beams (for 1, 3 or 5 detectors) ensure the lowest possible patient dose, while simultaneously allowing for fast scan times and optimal patient throughput. l'acn has employed its expertise to create a dependable and yet extremely versatile answer to the requirements of any customer, from the high throughput clinics to the small private doctor’s practice. Quality control Automatic daily and real-time Quality Control are implemented in the software, ensuring the maximum reliability of the results by reducing the...

Open the catalog to page 3
Unigamma M - 4

Unigamma M TECHNICAL SPECIFICATIONS Principle: DEXA - small fan beam Patient dose: typ. 3 uSv for an AP spine scan Generator: HF, 86 keV at 0.4 mA (nominal) Cooling: Oil, convection Energies: 47 and 70 keV Separation: K-edge samarium filtered Filtration: min. 22 mm Al eq. Linearity range: 0 - 1500 mg/sqcm Precision: Approx. 1% Accuracy: Better than 1% Calibration: Compatible with industry standards Beam size: 2 mm effective diameter Scan time: typ AP spine 35 sec (5 detectors) Results: BMD ,BMD ,Area, T-Score, Z-score Bone edges: Automatic detection Dimensions: 2400*1300*1700 mm (l*w*h)...

Open the catalog to page 4