video corpo

Organic Sample Preparation
12Pages

{{requestButtons}}

Catalog excerpts

Organic Sample Preparation - 1

ORGANIC SAMPLE PREPARATION

Open the catalog to page 1
Organic Sample Preparation - 2

WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently than any other systems, LabTech WSPE vacuum manifold installs a patented valve system able to grant precise flow control through each cartridge. WSPE vacuum manifolds allows users to process up to 12 (WSPE12) or 24 (WSPE24) samples simultaneously. TECHNICAL FEATURES • Glass base resistant to solvents preventing condensation and discolor • Anticorrosion cover to avoid deformation under high-pressure working conditions • High quality and reliable PTFE rack • Screw-type...

Open the catalog to page 2
Organic Sample Preparation - 3

EXTRAPID MANUAL CARTRIDGE-DISK EXTRACTOR Extrapid manual SPE system is the ideal partner when treatment of large volume samples is required. A unique and flexible extraction solution for standard and routine SPE needs in environmental analysis. TECHNICAL FEATURES • 3-ways valves to efficiently control the sample collection and the waste discharge • During operation process: - No need to switch ON/OFF the vacuum pump - No need to wait for venting and removing collection vials - No need to drain the waste liquid and clean vacuum chamber • Up to 4 samples run individually or simultaneously • 1,...

Open the catalog to page 3
Organic Sample Preparation - 4

SEPATHS UP THE INNOVATIVE SPE SOLUTION Sepaths UP is designed for both cartridge and disk applications to treat samples with different volume. It can be applied to extract trace organic compounds from drinking water, surface water, ground water, food, beverage and other samples. Sepaths UP automatically treats from1 to 12 same or different samples, through the whole treatment process, including condition, sample loading, rinsing, elution and concentration. It is a closed system able to completely remove solvent vapors trough the included exhaust line. TECHNICAL FEATURES • • • • • • • • • •...

Open the catalog to page 4
Organic Sample Preparation - 5

Complete software solution Optional Concentration Module (E.T. Concentrator) • Possibility to run simultaneously different methods • Real-time process monitoring • Possibility to modify and create customized methods • Dedicated concentration for each channel • Fast concentration by nitrogen flow • Parallel concentration model Channel number Modular configuration for different number of samp

Open the catalog to page 5
Organic Sample Preparation - 6

SEPLINE-S AUTOMATION AND PRODUCTIVITY CONCEPT SepLine-S automated solid phase extractor is the result of latest liquid-solid extraction techniques and mass chromatography highest requirements in terms of sensitivity and reproducibility. Largely used in environmental protection, food, petrochemical, pharmaceutical, clinical, life sciences and other applications thanks to its flexibility. SepLine-S series includes three models: Single, Dual and Four-channels. Condition, sample loading, rinsing and elution steps are processed automatically by software according to user needs. A unique...

Open the catalog to page 6
Organic Sample Preparation - 7

Single channel AutoSPE system to perform single sample batch processing. It can automatically achieve conditioning, sample loading, rinsing and eluting steps. Thanks to the included nitrogen purge module, SepLine-S is the ideal partner for routine and R&D needs in the organic sample preparation. The new quantitative concentrator can be connected to the main unit by a plug-and-play procedure. Dual channels AutoSPE system to perform simultaneously two samples. Management system allows running different methods for each channel. Four channels AutoSPE system to perform simultaneously four...

Open the catalog to page 7
Organic Sample Preparation - 8

CARTRIDGE HOLDER MODULE • • • • • SPE cartridges are moved by sliders to the set position via software Optimized design to allow cartridge exchange 60 sample extractions automatically handled via PC software Compatible with the majority of SPE cartridge specifications Fully closed treatment process to avoid solvent vapors to ambient Positive pressure extraction mode to ensure stability of the recovery rate Low-pressure sealing technology Air bubble technique to prevents solvent/sample cross-contamination Closed system to ensure environmental protection. No additional consumables required...

Open the catalog to page 8
Organic Sample Preparation - 9

E.T. CONCENTRATOR BASIC SOLUTION FOR ANY LABORATORY TECHNICAL FEATURES • • • • • • • • • • Possibility to run up to 6 samples Parallel concentration model Possibility to simultaneously or separately work with six channels Nitrogen blow in combination of heating concentration mode Dry block heating mode to avoid potential water vapor interference P.I.D. temperature control with digital display Possibility to choose the best position of nitrogen needle to ensure the most efficient evaporation Dedicated nitrogen flow regulator control for each sample channel Compatibility with collection vials...

Open the catalog to page 9
Organic Sample Preparation - 10

MULTIVAP AUTOMATED CONCENTRATION SOLUTION The new LabTech MultiVap8 automatic parallel system increases the capacity and sample throughput in laboratories and maintains quality and lower costs. With this system users can evaporate to solid state or concentrate into a fixed end-point volume. A compact solution compared to conventional rotary evaporators, with the possibility to be used outside fume hood thanks to the integrated vapor exhausting system. TECHNICAL FEATURES • Vortex nitrogen purge to get the highest concentration efficiency. The location and direction of nitrogen purge can be...

Open the catalog to page 10
Organic Sample Preparation - 11

MV5 AUTOMATED CONCENTRATOR REVOLUTIONARY CONCEPT! MV5 is the latest multi-channel and multifunctional parallel instrument designed by LabTech, including all accessories and functions to grant highest standard of efficiency, speed, reliability, throughput and safety of any concentration process. Nitrogen sweeping, needle level adjustment and visible concentration process are only few of the advantages offered by MV5. TECHNICAL FEATURES • • • • • • • • 54 sample positions able to work either individually or simultaneously Automatic adjustment of nitrogen needle according to the sample volume...

Open the catalog to page 11

All LabTech catalogs and technical brochures

  1. HOTPLATES

    6 Pages

Archived catalogs