Product catalog summary
Main Features of ECG Simulator SIM-02:
  • Simulates Holter, Resting, and Stress Test ECG measurements.
  • Generates normal and arrhythmic QRS forms.
  • Compact, portable, and user-friendly device.
  • Produces various heart rate frequencies and ECG signs.
  • Equipped with an LCD display.
  • Operates with USB cable or rechargeable batteries, lasting up to 80 hours.
  • Includes a low battery indicator.
  • Compatible with banana plugs and patent clips.
Programs and Waveforms:
  • ECG, Sine, Square, Triangle waveforms.
  • Normal Sinus Rhythm at 30, 60, 90, 120, 150, 180, 210 BPM.
  • Arrhythmia types include Sinus Arrhythmia, Atrial Fibrillation, Atrial Flutter, and more.
  • Block indicators for AV I, AV II, Left and Right Bundle Branch Blocks.
  • ST segment elevation and depression detection.
Technical Specifications:
  • Signal Amplitude: Fixed, 1.0 mV peak to peak +/- 10%.
  • Noise Source: Baseline, main supply 50 Hz.
  • Functional Leads: R, L, F, N, C1-C6 for 12CH ECG; N, CH1+, CH1-, CH2+, CH2-, CH3+, CH3- for Holter-bipolar.
  • Dynamic Interval: +/- 3mV.
  • Update Rate Frequency: 512 Hz.
  • D/A Resolution: 12 bit.
  • Memory: SD card.
  • Power Supply: USB cable or 2 AA rechargeable batteries.
  • Operating Temperature: 10°C to +50°C; Non-operating: 10°C to +60°C.
  • Operating Humidity: 10% to 95% (non-condensing).
  • Dimensions: 70*125*33 mm; Weight: 170 g.
  • Accuracy: Amplitude +/- 10%, Frequency 1%.
Contact Information:
  • Labtech Ltd., 4031 Debrecen, Vag Street 4, Hungary.
  • Tel: +36 / 52-310-128, Fax: +36 / 52-412-023.
  • Email: [email protected], Web: www.labtech.hu.
See more

Catalog excerpts

SIM-02 leaflet --1

MAIN FEATURES: Simulates Holter, Resting and Stress Test ECG measurements Generates normal and arrhythmic QRS forms Compact, portable, user-friendly and easy to use device Generates several Heart Rate frequency and several types of ECG signs LCD Display Works with two different power supplies: USB cable or rechargeable batteries Works up to 80 hours Indicates low battery signal Suitable for using banana plugs and patent clips

 Open the catalog to page 1
SIM-02 leaflet --2

TECHNICAL SPECIFICATIONS SIM-02 Programs Waveforms Normal Sinus Rhythm Arrythmia Block ST segment Signal Amplitude Noise source ECG, Sine, Square, Triangle Sinus Rhythm of 30, 60, 90, 120, 150, 180, 210 BPM Sinus Arrhythmia, Artefact, Atrial Fibrillation, Atrial Flutter, SV Premature beat, Paroxismal SVTCH, Pause, V Premature Beat, V Bigeminy, V Couplet, V Run, V Tachycardia Indicates AV I, AV II, Left Bundle BB, Right Bundle BB. Indicates elevation and depression Fixed, 1.0 mV peak to peak +/- 10% Baseline, main supply 50 Hz Functional Leads Dynamic interval Update Rate Frequency D/A resolution...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.