MICROBIOLOGICAL SAFETY CABINETS Class II
16Pages

{{requestButtons}}

Catalog excerpts

MICROBIOLOGICAL SAFETY CABINETS Class II - 1

The document is interactive and by clicking the active icons you can go to an associated product webpage, brochure or video: Video

Open the catalog to page 1
MICROBIOLOGICAL SAFETY CABINETS Class II - 2

LAMSYSTEMS BMB-N-«Laminar-S.» Neater** MICROBIOLOGICAL SAFETY CABINETS Class II Conforms to EN 12469:2000 - Physical isolation (containment and controlled removal from the work zone) of pathogenic biological agents (PBA) and microorganisms to prevent airborne infection of the staff and contamination of the air in the work room and laboratory environment. - Minimization of risk of contamination and crosscontamination of the product. - Possibility to work with small amount of toxic chemicals and radionuclides as well as to remove work agent odors in case of mandatory connection to an active...

Open the catalog to page 2
MICROBIOLOGICAL SAFETY CABINETS Class II - 3

MAIN CHARACTERISTICS * Dimensions do not account for outstanding supports. ** Power when HEPA filters are new (not clogged). AIRFLOW LAYOUT DIMENSIONAL DRAWING

Open the catalog to page 3
MICROBIOLOGICAL SAFETY CABINETS Class II - 4

MICROBIOLOGICAL SAFETY CABINETS Class II EH[ - Physical isolation (containment and controlled removal from the work zone) of pathogenic biological agents (PBA) and microorganisms to prevent airborne infection of the staff and contamination of the air in the work room and laboratory environment. - Minimization of risk of contamination and cross-contamination of the product. - Possibility to work with small amount of toxic chemicals and radionuclides as well as to remove work agent odors in case of mandatory connection to an active exhaust system using an exhaust hood supplied upon customer's...

Open the catalog to page 4
MICROBIOLOGICAL SAFETY CABINETS Class II - 5

BMB-II-«Laminar-S.» SAVVY DIMENSIONAL DRAWING room air clean (filtered) air contaminated air

Open the catalog to page 5
MICROBIOLOGICAL SAFETY CABINETS Class II - 6

MICROBIOLOGICAL SAFETY CABINETS Class II PULLOUT UV UNIT: - does not disturb the laminar flow - does not require any additional space for storage - reliable and simple in operation - well-adapted for disinfection - completely closes the front opening when equipment is inoperative - controlled with optical position sensor - passed international certification HAS ALL THE ADVANTAGES OF SAVVY MODEL (see page 4) DISTINCTION FROM SAVVY MODEL: POWER-DRIVEN FRONT SASH Five preset positions of the front sash: 1. OPERATING POSITION in Main Operation mode. 2. UP POSITION for work chamber...

Open the catalog to page 6
MICROBIOLOGICAL SAFETY CABINETS Class II - 7

DIMENSIONAL DRAWING AIRFLOW LAYOUT room air clean (filtered) air contaminated

Open the catalog to page 7
MICROBIOLOGICAL SAFETY CABINETS Class II - 8

SAVVY CYTOS MICROBIOLOGICAL SAFETY CABINETS Class II Manual hinged front sash TOXIC CYTOSTATIC – Protection of the personnel from the impact of cytostatic and cytotoxic agents that are manipulated in the work chamber. – Aseptic production of antineoplastic agents. – Reduction of risk of infection of an operator working with airborne pathogenic agents and microorganisms, protection of the environment as well as the product from external contamination and cross-contamination. – In case the cabinet is used for work with biological pathogens and high-risk (especially hazardous) microorganisms,...

Open the catalog to page 8
MICROBIOLOGICAL SAFETY CABINETS Class II - 9

BMB-II-«Laminar-S.» SAVVY CYTOS DIMENSIONAL DRAWING

Open the catalog to page 9
MICROBIOLOGICAL SAFETY CABINETS Class II - 10

- Protection of the personnel from the impact of cytostatic and cytotoxic agents that are manipulated in the work chamber. - Aseptic production of antineoplastic agents. - Reduction of risk of infection of an operator working with airborne pathogenic agents and microorganisms, protection of the environment as well as the product from external contamination and cross-contamination. - In case the cabinet is used for work with biological pathogens and high-risk (especially hazardous) microorganisms, a corresponding protective (antiplague) coverall shall be used. SAVVY SL CYTOS * Not for sale...

Open the catalog to page 10
MICROBIOLOGICAL SAFETY CABINETS Class II - 11

BMB-II-«Laminar-S.» SAVVY SL CYTOS DIMENSIONAL DRAWING

Open the catalog to page 11
MICROBIOLOGICAL SAFETY CABINETS Class II - 12

SAVVY B2, NEOTERIC B2 BMB-N-«Laminar-S.» MICROBIOLOGICAL SAFETY CABINETS EH[ C€ - Physical isolation (containment and controlled removal from the work zone) of pathogenic biological agents (PBA) and microorganisms to prevent airborne infection of the staff and contamination of the air in the work room and laboratory environment. - Minimization of risk of contamination and cross-contamination of the product. - Equipment of individual work places in medical, pharmaceutical and other institutions working with pathogenic biological agents and microorganisms. No recirculation in the cabinet...

Open the catalog to page 12
MICROBIOLOGICAL SAFETY CABINETS Class II - 13

MAIN PARAMETERS AND DIMENSIONS DIMENSIONAL DRAWING

Open the catalog to page 13
MICROBIOLOGICAL SAFETY CABINETS Class II - 14

LAMSYSTEMS CC DESIGN, MANUFACTURE, SALE AND MAINTENANCE OF HIGH-TECHNOLOGY LABORATORY EQUIPMENT, CLEAN ZONES AND CLEAN ROOMS About 7000 square meters of production facilities are fitted with up-to-date machines and equipment of well-known international brands, i.e. from German, Japanese and Swiss manufacturers. Annual output amounts to about 2500 units. More than 30 models are serial. LAMSYSTEMS products are supplied to numerous countries of CIS, Europe and Asia. LAMSYSTEMS is a top supplier in the market of the Russian Federation – 80%. ACCEPTANCE TESTING All of the products manufactured...

Open the catalog to page 14
MICROBIOLOGICAL SAFETY CABINETS Class II - 15

LABORATORY EQUIPMENT FOR FACTORIES AND LABORATORIES WITH STRICT REQUIREMENTS TO AIR CLEANLINESS Operation with cytostatic and cytotoxic products Operation with pathogenic biological agents (PBA) Class I LAMINAR FLOW CABINETS Operation with PBA, small amounts of toxic and chemical substances MICROBIOLOGICAL SAFETY CABINETS FUME HOODS ISOLATORS (GLOVE BOXES) STERILE STORAGE CABINETS CUSTOMIZED ASSEMBLY WE ARE ABLE TO CREATE CONTINUOUS TECHNOLOGICAL PROCESS LINES BASED ON OUR EQUIPMENT. The lines can consist of biosafety cabinets, laminar flow cabinets, fume hoods, positive and...

Open the catalog to page 15
MICROBIOLOGICAL SAFETY CABINETS Class II - 16

LAMSYSTEMS MICROBIOLOGICAL SAFETY CABINETS - Technical gas tap with electromagnetic valve* - Inflammable gas tap with electromagnetic valve* - Vacuum tap with electromagnetic valve* - Exhaust hood for connecting the cabinet to the exhaust system - Additional sockets - ULPA filters - Hydrogen peroxide (H2O2) disinfection kit - Holes in side walls - Cabinet base stand * The electromagnetic valve automatically locks gas and vacuum supply in case of power cutoff, the cabinet switching-off or alarm activation. LAMSYSTEMS LAMSYSTEMS CC Turgoyak Road, 2/4 Miass, Chelyabinsk region 456300 Russian...

Open the catalog to page 16

All LAMSYSTEMS catalogs and technical brochures